background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

UNI13-Q60-232 / UNI13-Q60-USB 

 

 

RFID read/write module 

13.56 MHz closed coupling 

 

 iID

®

Reader 

 

Summary of Contents for iID UNI13-Q60-232

Page 1: ...User Manual UNI13 Q60 232 UNI13 Q60 USB RFID read write module 13 56 MHz closed coupling iID Reader ...

Page 2: ...er Manual UNI13 Q60 232 USB Contact Copyright microsensys GmbH Office Park im GVZ In der Hochstedter Ecke 2 99098 Erfurt Germany tel 49 0 3 61 5 98 74 0 fax 49 0 3 61 5 98 74 17 e mail info microsensys de homepage www microsensys de ...

Page 3: ... In order to avoid the possibility of exceeding the FCC radio frequency exposure limits human proximity to the antenna shall not be less than 20cm 8inches during normal operation These devices may not be co located with any other transmitter or transmitter antenna NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rul...

Page 4: ...d further The UNI16 Q60 is available in two types with a serial interface and with a USB interface to the host computer This product is designed for use in industrial environment together with a host such as handheld devices or laptops The small size and the integrated antenna on the front side of the UNI13 Q60 module allow a simple use in many different applications For the mechanical mounting of...

Page 5: ...ent consumption typ 100mA active mode with active RF field typ 10mA idle mode without RF field Connector serial interface USB interface BLR 125Z standard USB Type A Fischer Elektronik Voltage Level serial interface USB interface high 0 85 VCC VCC according USB 1 1 standard low GND 0 15 VCC Protocol baudrate 57 6 kabaud data bits 8 stop bits 1 parity no Software interface iID Driver Engine for Wind...

Page 6: ...56MHz 7kHz RF output power 200mW Implemented standards ISO15693 ISO14443B Anticollision not implemented Antenna type P13 Operating distance 0 50 mm depending on transponder type and environment conditions Ordering information Product Product code UNI13 Q60 232 25 26 603 02 UNI13 Q60 USB 25 29 600 02 ...

Page 7: ...e manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation operation and maintenance procedures should only be carried out by qualified personnel Use of the device and its installation must be in accordance with national legal requirements and local electrical codes When working on devices the vali...

Page 8: ...Page 8 2011 microsensys GmbH User Manual UNI13 Q60 232 USB ...