background image

12062340-01

Installation

*INSTALLATION*

Before installation

Before installation, it is important

to read the information given on the
following pages as well as the
“Warning and Safety instructions” at
the beginning of this booklet.

Installation recommendations

- To achieve optimum vapour

extraction, the cooker hood must be
positioned centrally over the hob, not
to the side.

- The hob should be no wider than the

cooker hood, and if possible, it
should be narrower.

- The installation area must be easily

accessible. The cooker hood should
be easily accessible and easy to
dismantle in the event that service is
required. This should be taken into
consideration when planning the
position of cupboards, shelves,
ceilings or features in the vicinity of
the cooker hood.

Installation materials

1 vent connection

for exhaust ducting 

 150 mm.

1 non-return flap

for fitting into the exhaust socket on
the motor unit (not needed for
recirculation mode). Depending on the
model, the non-return flap may already
be fitted.

4 mounting plates

for installation in a 600 mm wide
cabinet

2 brackets

for installation in a 900 mm wide
cabinet (only for 900 mm wide
appliances)

2 spring clips

for installation in a 900 mm wide
cabinet (only for 900 mm wide
appliances)

1 spacer strip

for concealing the gap between the
rear of the appliance and the wall

Summary of Contents for DAS 4620

Page 1: ...y to dismantle in the event that service is required This should be taken into consideration when planning the position of cupboards shelves ceilings or features in the vicinity of the cooker hood Installation materials 1 vent connection for exhaust ducting 150 mm 1 non return flap for fitting into the exhaust socket on the motor unit not needed for recirculation mode Depending on the model the no...

Page 2: ...1839970 DML 2000 installation kit for installing a hinged front panel to match kitchen furniture units not supplied available as an optional accessory Installation materials for recirculation mode You need the following optional accessories for recirculation mode DFKS 31 x installation kit contains 2 holders and 2 charcoal filters DFKS 31 P with single use charcoal filters or DFKS 31 R with reacti...

Page 3: ...12062340 01 Installation INSTALLATION Appliance dimensions Dia 1 DAS 4620 in a 600 mm wide cabinet The drawing is not to scale ...

Page 4: ...12062340 01 Installation INSTALLATION Dia 2 DAS 4920 in a 900 mm wide cabinet The drawing is not to scale See diagram 1 for side view ...

Page 5: ...e cabinet it must be removable c Extraction or recirculation with conversion kit DUU 150 d DML 2000 bracket optional accessory for fitting a front panel In this installation situation the deflector plate is flush with the front edge of the housing unit carcase If you wish to position the cooker hood further forward or further back you must adapt the dimensions accordingly e g if you are using a fr...

Page 6: ...Electric hob 450 mm Electric grill deep fat fryer electric 650 mm Multi burner gas hob total output 12 6 kW no burner 4 5 kW 650 mm Multi burner gas hob total output 12 6 kW and 21 6 kW no burner 4 8 kW 760 mm Multi burner gas hob total output 21 6 kW or multi burner gas hob where one burner 4 8 kW Not possible Single burner gas hob output 6 kW 650 mm Single burner gas hob output 6 kW and 8 1 kW 7...

Page 7: ... the lowest noise levels please note the following The diameter of the exhaust ducting must not be smaller than the cross section of the exhaust duct see Appliance dimensions This applies in particular when using flat ducting The exhaust ducting should be as short and straight as possible Only use wide radius bends The exhaust ducting must not be kinked or compressed All connections must be strong...

Page 8: ...n temperature between the different areas can cause condensation to form Insulate the exhaust ducting to reduce temperature variations If the exhaust ducting is to be laid horizontally it must be laid with a downwards sloping gradient of at least 1 cm per meter This is to ensure that condensation cannot drain back into the cooker hood In addition to insulating the exhaust ducting it is advisable t...

Page 9: ...ot only reduces noise from the fan outside the house but also sounds originating outside reaching the kitchen through the exhaust ducting e g traffic noise For this reason the silencer must be positioned as close as possible to the ducting exit In recirculation mode the silencer needs to be positioned between the exhaust vent and the exhaust grille Check that there is sufficient space ...

Page 10: ...he Miele Customer Service Department For safety reasons such replacement may only be carried out by a qualified specialist or the Miele Customer Service Department These operating instructions and the data plate indicate the nominal power consumption and the appropriate fuse rating Compare this information with the data of the on site electrical connection If in any doubt consult a qualified elect...