background image

OU FLEX -027 INSTALLATION AND OPERATION MANUAL 

OU FLEX - 027

Installation and Operation Manual 

Issue E-1

OU FLEX Shelf - 027

OU FLEX Operation Manual

Summary of Contents for OU Flex 027

Page 1: ...OU FLEX 027 INSTALLATION AND OPERATION MANUAL OU FLEX 027 Installation and Operation Manual Issue E 1 OU FLEX Shelf 027 OU FLEX Operation Manual...

Page 2: ...it Rear panel OU FLEX modem Newtec MDM3310 Modem front panel LED indication Connecting to the OU FLEX shelf Lan WiFi router Modem configuration Expert mode Logging into expert mode BUC and LNB set up...

Page 3: ...re frequency 14155 75 MHz Horizontal DVB S2 MxDMA Astra 3B beacon frequency 11446 75 MHz Horizontal NOTE There is a 8 POL Off set so a calculated POL angle of 72 will be 80 Coverage on ASTRA 3B OU FLE...

Page 4: ...s required is to feed the existing transmit and receive L band coaxial cables through the OU FLEX shelf The connectors on the back of the OU FLEX shelf are N Type connectors The shelf is mains powered...

Page 5: ...OU FLEX 027 INSTALLATION AND OPERATION MANUAL PAGE 5 OU FLEX SHELF 027 Front Panel and Top of the unit Rear Panel NOTE All connections are N Type 50...

Page 6: ...Router LAN IP ADDRESS 192 168 1 254 Password WIFI OUFLEX027 LAN User admin NONE For Traffic set your PC to accept DHCP for LAN and WiFi Range 192 18 1 100 192 168 1 200 CONNECTING TO THE OU FLEX SHELF...

Page 7: ...ompted for the Expert password in order to start the installation procedure If your OU FLEX shelf has already been installed before you are re directed to the Status page of the terminal When the term...

Page 8: ...PAGE 8 EXPERT MODE The Expert mode will allow you to edit the modem parameters and conduct the line up tests Logging into expert mode Type into the URL bar http 192 168 1 1 cgi bin index ilogin NOTE i...

Page 9: ...e ODU type ID 27 OU FLEX customer INPUT 2 Select your LNB set up single band or switchable 22 KHz tone ON OFF Voltage 13V or 18V 3 Select your LNB LO and start stop SHF frequency 4 Enter the current l...

Page 10: ...the correct modem TX output level When doing so the terminal transmits a modulated signal or pure carrier This signal can only be picked up and measured at the network hub site when the terminal is co...

Page 11: ...on their requirement for throughput and time Bookings can be entered and also modified online as required How to access the booking tool online Open a web browser and enter the URL https www ses 360 c...

Page 12: ...een On this screen you can see your up coming events with the event name date start time end time and duration On the right hand side is the status of the booking which will either be pencil which mea...

Page 13: ...IP over satellite or pure satellite capacity which is also bookable through this portal Select IP over satellite You will then see a screen that asks you to enter the type of service and throughput y...

Page 14: ...ption and the location You also have to enter the modem ID that has been agreed with SES during registration and an SNG registration with SES if you have one Then click Next You will then see a screen...

Page 15: ...BOOKING Click Submit and then OK after you receive a thank you for booking message This will take you back to the OU Service page where you will see your booking awaiting approval Once approved you w...

Page 16: ...OU FLEX 027 INSTALLATION AND OPERATION MANUAL PAGE 16 APPENDIX A SYSTEM RESET Hold down the reset button and power cycle...

Page 17: ...OU FLEX 027 INSTALLATION AND OPERATION MANUAL PAGE 17 APPENDIX B ROUTER SET UP...