background image

WARNING

 

 

4. USE ONLY WITH CERTIFIED POWER SUPPLY.

 Others may result in 

SPECIFICATIONS

SYMBOLOGY

 

 

 

 

 

Direct Current

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS

READ AND  UNDERSTAND ALL  INSTRUCTIONS. 

Failure  to  follow  all  instructions  listed  below,  may 

result in electric shock, fire and/or serious personal injury.

1. THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING 

SAVE THESE INSTRUCTIONS

INSTRUCTIONS FOR THE REDLITHIUM

®

 USB CHARGER CAT. NO. 

L4C AND BATTERY CAT. NO. L4B2.

.

2.  CHARGE  ONLY  REDLITHIUM

®

  USB  BATTERIES  IN  THE 

REDLITHIUM

®

  USB  CHARGER.  OTHER  TYPES  OF  BATTERIES 

MAY CAUSE PERSONAL INJURY AND DAMAGE.

3.  BEFORE  USING  THE  BATTERY  AND  CHARGER,  READ  THIS 

OPERATOR’S  MANUAL,  YOUR  TOOL  OPERATOR’S  MANUAL, 

AND ALL LABELS ON THE BATTERY, CHARGER AND TOOL.

a risk of fire, electric shock or personal injury.

5. AVOID DANGEROUS ENVIRONMENTS. 

Do not charge battery in rain, 

snow,  damp  or  wet  locations.  Do  not  use  battery  or  charger  in  the 

presence  of  explosive  atmospheres  (gaseous  fumes,  dust  or 

flammable  materials)  because  sparks  may  be  generated  when 

inserting or removing battery, possibly causing fire.

6. 

CHARGE IN A WELL VENTILATED AREA. 

Do not block charger vents. 

Keep them clear to allow proper ventilation. Do not allow smoking or 

open flames near a charging battery. Vented gases may explode.

7. MAINTAIN CORD. 

When unplugging charger, pull plug rather than cord 

to reduce the risk of damage to the electrical plug and cord. Never carry 

charger by its cord. Keep cord from heat, oil and sharp edges. Make 

sure cord will not be stepped on, tripped over or subjected to damage or 

stress. Do not use charger with damaged cord or plug. Have a damaged 

charger replaced immediately.

8. 

USE ONLY RECOMMENDED ATTACHMENTS. 

Use of an attachment 

not recommended or sold by the battery charger or battery manufacturer 

may result in a risk of fire, electric shock or personal injury.

9.  TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK, 

always  unplug 

charger before cleaning or maintenance.

10. DO NOT BURN OR INCINERATE BATTERY PACKS.

 Battery may 

explode, causing personal injury or damage. Toxic fumes and materials 

are created when battery are burned.

11. DO NOT CRUSH, DROP, OR DAMAGE battery. 

Do not use a battery 

or charger that has received a sharp blow, been dropped, run over, or 

damaged  in  any  way  (e.g.,  pierced  with  a  nail,  hit  with  a  hammer, 

stepped on).

12. DO NOT DISASSEMBLE.

 Incorrect reassembly may result in the risk 

of electric shock, fire or exposure to battery chemicals. If it is damaged, 

take it to a 

MILWAUKEE

®

 service facility.

13.  BATTERY  CHEMICALS  CAUSE  SERIOUS  BURNS. 

Never  allow 

contact with skin, eyes, or mouth. If a damaged battery leaks battery 

chemicals,  use  rubber  or  neoprene  gloves  to  dispose  of  it.  If  skin  is 

exposed  to  battery  fluids,  wash  with  soap  and  water  and  rinse  with 

vinegar. If eyes are exposed to battery chemicals, immediately flush with 

water for 20 minutes and seek medical attention. Remove and dispose 

of contaminated clothing.

14. DO NOT SHORT CIRCUIT.

 A battery will short circuit if a metal object 

makes a connection between the positive and negative contacts on the 

battery pack. Do not place a battery pack near anything that may cause 

a  short  circuit,  such  as  coins,  keys  or  nails  in  your  pocket. A  short 

circuited battery may cause fire and personal injury.

15. STORE YOUR BATTERY AND CHARGER in a cool, dry place.

 Do 

not store battery where temperatures may exceed 50°C (120°F) such as 

in direct sunlight, a vehicle or metal building during the summer.

To  reduce  the  risk  of  fire,  personal  injury,  and  product 

damage  due  to  a  short  circuit,  never  immerse  your  tool, 

READ AND SAVE ALL INSTRUCTIONS FOR FUTURE REFERENCE.

ADDITIONAL BATTERY SAFETY RULES

WARNING

battery pack or charger in fluid or allow a fluid to flow inside them. Corrosive or 

conductive fluids, such as seawater, certain industrial chemicals, and bleach or 

bleach-containing products, etc., can cause a short circuit.

Charger Cat. No. ..........................................................................................L4C

Input Volts................................................................................................... 5 DC

Input Watts....................................................................................................10W

Output Volts................................................................................................ 4 DC

Output Amps................................................................................................ 2.1A

Battery Cat. No...........................................................................................L4B2

Volts............................................................................................................ 4 DC

Operating Temperature

  Battery and Charger...............................................4°C to 40°C (40°F to 104°F)

  Battery and Tool....................................................-18°C to 65°C (0°F to 149°F)

Power Supply Cat. No...............................................................4931 4605 95A

Wall Plug Input Volts.........................................................120 AC to 220-240 AC

Volts

V

Read Operator's Manual

BATTERY

CHARGER

WARNING

Maintenance and Storage

Do not expose your battery or cordless tools to water or rain, or allow them to get 

wet. This could damage the tool and battery. Do not use oil or solvents to clean 

or  lubricate  your  battery.  The  plastic  casing  will  become  brittle  and  crack, 

causing a risk of injury.

Store batteries at room temperature away from moisture. Do not store in damp 

locations where corrosion of terminals may occur. As with other battery types, 

permanent capacity loss can result if the pack is stored for long periods of time 

at  high  temperatures  (over  49°C(120°F)). 

MILWAUKEE

®

  Li-Ion  batteries 

maintain their charge during storage longer than other battery types. After about 

a year of storage, charge the battery as normal.

To reduce the risk of injury or explosion, never burn or 

incinerate a battery pack even if it is damaged, dead or 

completely  discharged.  When  burned,  toxic  fumes  and  materials  are 

created.

Disposing of 

MILWAUKEE

®

  Li-Ion Battery

MILWAUKEE

®

 

Li-Ion  batteries  are  more  environmentally  friendly  than  some 

other types of power tool batteries. Always dispose of your battery according to 

federal, state and local regulations. Contact a recycling

agency in your area for recycling locations.

Even discharged batteries contain some energy. Before disposing, use electrical 

tape to cover the terminals to prevent the battery from shorting, which could 

cause a fire or explosion.

WARNING

REDLITHIUM

®

  USB  BATTERY AND 

CHARGER

How to Charge the Battery Pack

6. The indicator light will display the charging status:

       Red Flashing: Charging, 0-25% charged

       Orange Flashing: Charging, 25-80% charged

       Green Flashing: Charging, 80-99% charged

       Green Solid: 99-100% Charged

       Red/Green Flashing: Damaged or Faulty Battery

 

Amps

A

Regulatory Compliance mark 

(RCM). This product meets 

applicable regulatory 

requirements.

Additional Safety Rules

This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the 

appliance.

This charger was only 

suitable for indoor use. 

Never expose the 

charger to rain.

Class III appliance

T3.0A

Time-lag fuse 3.0A

Charge only REDLITHIUM

®

 USB batteries 

in the REDLITHIUM

®

 USB charger. Other 

types of batteries may cause personal injury and damage.

1. Plug your USB cable into a power source such as an AC wall 

adaptor, computer or car port.

2. Insert the micro USB into the micro USB port.

3. Twist the charger cap and pull out the charger bay.

4. Align the battery arrow with the charger arrow and insert the 

battery completely.

5. Close the battery bay and twist the cap to lock.

If the light indicator flashes red and green, check that the 

battery is fully seated into the bay. Remove the battery and 

reinsert. If the light continues to flash red and green, the 

battery may be extremely hot or cold, or wet. Allow the 

battery to cool down, warm up, or dry out and then reinsert. 

If the problem persists, contact a 

MILWAUKEE

®

 service 

facility.

Fuel Gauge

When  the  charger  is  unplugged  and  a  battery  is  inserted,  the 

indicator light will display the current battery charge:

    Red Flashing: 0-10% remaining

    Red Solid: 10-25% remaining

   Orange Solid: 25-80% remaining

   Green Solid: 80-100% remaining

WARNING

To reduce the risk of injury, always unplug 

the  charger  and  remove  the  battery  from 

the charger before performing any maintenance. The charger 

and  battery  have  no  internal  serviceable  parts.  Never 

disassemble the battery or charger.

Maintenance and Storage

Store your charger in a cool, dry place. As a general practice, it is 

best to unplug battery chargers and remove batteries when not in 

use.  No  battery  damage  will  occur,  however,  if  the  charger  and 

battery are left plugged in.

WARNING

To  reduce  the  risk  of  injury  and  damage, 

never immerse your battery or charger in 

liquid or allow a liquid to flow inside them.

Cleaning

Clean  out  dust  and  debris  from  charger  vents  and  electrical 

contacts by blowing with compressed air. Use only mild soap and a 

damp cloth to clean the battery and charger, keeping away from all 

electrical  contacts.  Certain  cleaning  agents  and  solvents  are 

harmful to plastics and other insulated parts. Some of these include 

gasoline,  turpentine,  lacquer  thinner,  paint  thinner,  chlorinated 

cleaning solvents, ammonia and household detergents containing 

ammonia.  Never  use  flammable  or  combustible  solvents  around 

batteries, charger, or tools.

Reviews: