C1XP02-115AC Instruction Guide

Specifications

Line Voltage

115 VAC, ±10%; single phase, 50/60 Hz

Horsepower Range

1/20 – 1/8 Hp

Armature Voltage Range

0 – 130 VDC

Maximum Armature Current (continuous)

2 ADC

Acceleration Time (no load)

1 second

Deceleration Time (no load)

4 seconds

Speed Regulation (at base speed)

1% 

Line Fuse

5 A (fast-acting)

Weight

0.68 lb

Dimensions

5.50 in. x 3.50 in. x 3.20 in. 

Ambient Temperature Range

10°C – 40°C

Safety Warnings

•  Have a qualified electrical maintenance technician install, adjust, and service this

equipment. Follow the National Electrical Code and all other applicable electrical and
safety codes, including the provisions of the Occupational Safety and Health Act
(OSHA) when installing equipment.

•  Reduce the chance of an electrical fire, shock, or explosion by proper grounding, 

over current protection, thermal protection, and enclosure. Follow sound maintenance
procedures.

•  Although the drive includes protective circuitry to prevent damage in the event of 

an accidental short circuit of the armature, it is not fail-safe. It is possible for a drive
to run at full speed as a result of a component failure. Install a master switch in the
drive’s AC line for stopping the drive in an emergency.

•  This drive is not isolated from earth ground. Circuit potentials are at 115 VAC 

above earth ground. Avoid direct contact with the printed circuit board or with 
circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic
screwdriver for adjusting the calibration trimpots.