Features
•
1200 pound minimum holding force
•
Compatible with all access/egress systems
•
Alluminum/stainless casings are weather and
vandal resistant
•
On board mov’s provide protection against
voltage spikes and surges
•
Assorted mounting brackets and filler plates
available
Description
The MIR12B model contains a bond sensor to indicate that the door is secure, an internal timer that eliminates
the need for add-on exit delays timers and a door status switch, relay and LED.
7908
NOT TO BE USED FOR INSTALLATION PURPOSES.
CATALOG NUMBER
Power Selector Jumpers:
A. 12V DC Input:
To set jumpers for 12V DC operation connect the
ground (-) lead from a 12V DC power source to
terminal 2. Connect the positive (+) lead from a 12V
DC power source to terminal 1.
B. 24V DC Input:
Unit is delivered from Factory with single jumper
ON for 24V operation. Connect the ground (-) lead
from a 24V DC power source to terminal 2. Connect
the positive (+) lead from a 24V DC power source
to terminal.
C. Contacts:
Door Position Reed Switch dry contacts are rated
0.5A@30 V DC/AC.
Bond Sensor Output Relay dry contacts are rated
1.0A@30VDC.
For safe operation, do not exceed this rating.
Note:
Only use UL/CUL Listed Regulated Limited Power Source.
Power Supply Wiring
Requirements
In context with the Power switch or
solid state switching device instal-
lation to minimize the effect of re-
sidual magnetism install switch at
location indicated in the schematic
diagram “CORRECT”.
Magnetic Lock wiring Instructions
110 V AC
Switch or Solid State
Switching Device
12
or
24
VDC
CORRECT
110 V AC
Switch or Solid State
Switching Device
12
or
24
VDC
INCORRECT