This installation manual describes how to install the MA Remote Controller for use with Mitsubishi Building Air Conditioning System, direct 
expansion type CITY MULTI air conditioner indoor units (“-A” type and later), and Mitsubishi Mr. SLIM packaged air conditioners. 
Please be sure to read this installation manual and the files on the CD-ROM that is supplied with the Remote Controller before proceeding 
with the installation. Failure to follow the instructions may result in equipment damage.
For information not contained in this booklet, please refer to the files on the CD-ROM that is supplied with the Remote Controller.
If the files are not readable, please contact your dealer.
For information on how to wire and install the air conditioning units, refer to the installation manual. 
After the installation, hand over this manual to users.

1. Safety Precautions

• Thoroughly read the following safety precautions prior to installation.
• Observe these precautions carefully to ensure safety.

• After reading this manual, pass it on to the end user to retain for future reference.
• Keep this manual for future reference and refer to it as necessary. This manual should be made available to those who repair or relocate 

the controller. Make sure that the manual is passed on to any future users.

 WARNING

 CAUTION

 WARNING

Indicates a risk of death or serious injury.

 CAUTION

Indicates a risk of serious injury or structural damage.

 

General precautions

WT06695X01_

1

GB

CITY MULTI Control System
and Mitsubishi Mr. SLIM Air Conditioners 

MA Remote Controller     PAR-31MAA

Installation Manual 

For distribution to dealers and contractors

All electric work must be performed by qualified personnel.

Do not install the unit in a place where large amounts of oil, steam, 
organic solvents, or corrosive gases, such as sulfuric gas, are present 
or where acidic/alkaline solutions or sprays are used frequently. These 
substances can compromise the performance of the unit or cause 
certain components of the unit to corrode, which can result in electric 
shock, malfunctions, smoke, or fire.

To reduce the risk of shorting, current leakage, electric shock, 
malfunctions, smoke, or fire, do not wash the controller with water 
or any other liquid.

To reduce the risk of electric shock, malfunctions, smoke or fire, do 
not operate the switches/buttons or touch other electrical parts with 
wet hands.

To reduce the risk of injury or electric shock, before spraying a 
chemical around the controller, stop the operation and cover the 
controller.

To reduce the risk of injury or electric shock, stop the operation and 
switch off the power supply before cleaning, maintaining, or inspecting 
the controller.

Properly install all required covers to keep moisture and dust out of the 
controller. Dust accumulation and water can cause electric shock, 
smoke, or fire.

To reduce the risk of injury, keep children away while installing, 
inspecting, or repairing the controller.

To reduce the risk of fire or explosion, do not place flammable 
materials or use flammable sprays around the controller.

To reduce the risk of damage to the controller, do not directly spray 
insecticide or other flammable sprays on the controller.

To reduce the risk of electric shock or malfunctions, do not touch 
the touch panel, switches, or buttons with a pointy or sharp object.

To reduce the risk of injury and electric shock, avoid contact with 
sharp edges of certain parts.

To avoid injury from broken glass, do not apply excessive force on the 
glass parts.

To reduce the risk of injury, wear protective gear when working on the
controller.

WT06695X01_1_GB_A5.fm  Page 1  Tuesday, August 7, 2012  3:29 PM

Summary of Contents for PAR-31MAA

Page 1: ...nel Do not install the unit in a place where large amounts of oil steam organic solvents or corrosive gases such as sulfuric gas are present or where acidic alkaline solutions or sprays are used frequently These substances can compromise the performance of the unit or cause certain components of the unit to corrode which can result in electric shock malfunctions smoke or fire To reduce the risk of...

Page 2: ...risk of electric shock shorting or malfunctions keep wire pieces and sheath shavings out of the terminal block To reduce the risk of shorting current leakage electric shock or malfunctions keep the cables out of contact with controller edges To reduce the risk of electric shock malfunctions or fire seal the gap between the cables and cable access holes with putty The controller should be repaired ...

Page 3: ...he box WARNING The CD ROM that is supplied with the Remote Controller can only be played on a CD drive or a DVD drive Do not attempt to play this CD ROM on an audio CD player as this may damage your ears and or speakers 4 The front cover 1 is already installed on the top case 2 at factory shipment 5 Remote controller cable is not included To avoid damage to the controller provide protection agains...

Page 4: ... the remote controller where no wires are routed around the temperature sensor on the controller If wires are routed the sensor cannot measure accurate indoor temperature Parts name Qty Notes Double switch box 1 Not required for direct wall installation Thin metal conduit Necessary Lock nut and bushing Necessary Cable cover Necessary Required for routing remote controller cable along a wall Putty ...

Page 5: ...troller cable access hole at the connection of switch box and conduit tube with putty 3 Prepare the bottom case of the remote controller Direct wall installation Seal the hole through which the cable is threaded with putty To reduce the risk of electric shock malfunctions or fire seal the gap between the cables and cable access holes with putty Wall Conduit tube Locknut Switch box Seal the gap wit...

Page 6: ...n the cover indicated with the shaded area in the right figure with a knife or a nipper Thread the cable from the groove behind the bottom case through this access hole Installation using a switch box Direct wall installation Seal the cable access hole with putty Double switch box Roundhead cross slot screws Remote controller cable Wood screw Remote controller cable Thread the cable through the gr...

Page 7: ...bottom of the remote controller and move it in the direction of the arrow as shown in the figure at right Hold the cables in place with clamps to prevent undue force from being applied to the terminal block and causing cable breakage Important Clamp Insert the wire When attaching the cover and the top casing to the bottom casing push it until it they click into place If they are not properly locke...

Page 8: ...the protective sheet on the operation interface prior to use 3 Installing the cover and top case Two mounting tabs are at the top of the top case Hook those two tabs onto the bottom case and click the top case into place Install the cover on the top case in the same way as with the top case Check that the top case is securely installed and not lifted Note When temperature changes rapidly the tempe...

Page 9: ... Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Page Cursor Move the cursor to the desired function with the F1 and F2 buttons and press the SELECT button to go to the next page Password may be required The function of the MENU SELECT and RETURN buttons will appear on the setting screens Button function guide will appear at the bottom of the screens Pre...

Page 10: ...creen will be displayed Refer to section 11 8 Select a desired language The system will not start up without language selection Some models of City Multi cannot have more than one remote controller connected Refer to relevant documents e g catalogs for usage compatibility Normal start up indicating the percentage of process completion Notes When connecting two remote controllers be sure to designa...

Page 11: ...ange to bring up the clock display setting screen Use the F1 through F4 buttons to select Yes display or No non display and its format for the Main display Save the settings with the SELECT button The factory settings are Yes display and 24 h format Clock display Yes Time is displayed on the Main display No Time is not displayed on the Main display Display format 24 hour format 12 hour format AM P...

Page 12: ...and set each number 0 through 9 with the F3 or F4 button 2 Press the SELECT button Note The initial administrator password is 0000 Change the default password as necessary to prevent unauthorized access Have the password available for those who need it Note If you forget your administrator password you can initialize the password to the default password 0000 by pressing and holding the F1 and F2 b...

Page 13: ... following settings can be made from the Maintenance Information screen Registering model names and serial numbers Enter the model names and serial numbers of outdoor and indoor units The information entered will appear on the Error information screen Model names can have up to 18 characters and the serial numbers can have up to 8 characters Registering dealer information Enter phone number of a d...

Page 14: ... 1 2 3 4 or All for the Unit number These settings apply to each indoor unit If 1 2 3 or 4 is set for the Unit number the settings apply only to the specified indoor unit regardless of the number of connected indoor units one through four units If ALL is set for the Unit number the settings apply to all the connected indoor units regardless of the number of connected indoor units one through four ...

Page 15: ... 2 Other options in the Check menu Mr Slim only The following options are also available on the Mr Slim units in the Check menu Deleting the error history To delete the error history press the F4 button Delete on the screen that shows error history A confirmation screen will appear asking if you want to delete the error history Press the F4 button OK to delete the history Refrigerant volume check ...

Page 16: ...Resetting the error history 1 Press the F4 button Reset on the screen that shows the error history A confirmation screen will appear asking if you want to delete the error history 2 Press the F4 button OK to delete the error history If deletion fails Request rejected will appear and Unit not exist will appear if no indoor units that are correspond to the entered address are found Procedures 1 Sele...