MELSECNET/10 

Network Module

 

 

User's Manual

(Hardware)

 
 

A1SJ71LP21GE

 

 

  Thank you for buying the Mitsubishi general-purpose programmable 

controller MELSEC-A Series 

 

  Prior to use, please read both this manual and detailed manual 

thoroughly and familiarize yourself with the product. 

 

   

 

MODEL A1SJ71LP21GE-U-E 
MODEL

CODE 

13J886 

IB(NA)-66739-D(0706)MEE 

 

 

 

 

 

 

 

©

1996 MITSUBISHI ELECTRIC CORPORATION

 

 

Summary of Contents for A1SJ71LP21GE

Page 1: ...the Mitsubishi general purpose programmable controller MELSEC A Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL A1SJ71LP21GE U E MODEL CODE 13J886 IB NA 66739 D 0706 MEE 1996 MITSUBISHI ELECTRIC CORPORATION ...

Page 2: ...re this manual in a safe place and make it accessible when required Always forward it to the end user INSTALLATION PRECAUTIONS CAUTION z Use the programmable controller in an environment that meets the general specifications contained in CPU module user s manual Using this programmable controller in an environment outside the range of the general specifications could result in electric shock fire ...

Page 3: ...ause electric shocks or damage the product CAUTION z Be sure there are no foreign substances such as sawdust or wiring debris inside the module Such debris could cause fires damage or erroneous operation z Make sure to place the communication and power cables into a duct or fasten them using a clamp Cables not placed in the duct or not clamped may hang or shift allowing them to be accidentally pul...

Page 4: ...O network Reference Manual Compliance with the EMC Directive and the Low Voltage Directive When incorporating the Mitsubishi programmable controller into other industrial machinery or equipment and keeping compliance with the EMC and low voltage directives refer to Chapter 3 EMC Directive and Low Voltage Instruction of the User s Manual Hardware for the CPU module used or the programmable controll...

Page 5: ...sition of the Network Modules are indicated on the following chart Cable used Application Optical fiber cable Coaxial cable Position A1SJ71LP21GE The control station normal station and remote master station of MELSECNET 10 GI 62 5 125 cables Main base Extension base I O slot 2 After unpacking the Network Modules confirm that any of the following products is enclosed Model Description Quantity A1SJ...

Page 6: ... O stations 64 Overall distance Station to station distance 30km 2km Error control method Retry by CRC X16 X12 X5 1 and overtime RAS function y Loop back function due to abnormality detection and cable disconnection y Diagnostic function for local link circuit check y Prevention of system down due to shifting to control station Only for PLC to PLC networks y Abnormality detection by link special r...

Page 7: ...5μm Clad diameter 125μm Transmission loss 3dB km or less Wave length 0 85μm Transmission band 300 MHz km or more 2 Cable loss Optical module IN OUT RD SD RD SD A1SJ71LP21GE Conversion cable 1m 1 Adaptor Connection loss 1 dB max Connection loss 1 dB max Adaptor Conversion cable 1m RD SD RD SD IN OUT Total cable loss 7 5 dB or less 5 5 dB or less 1 Conversion cable Conversion Type Cable CA type FC t...

Page 8: ...inted wiring board from the case It may damage the module 3 When wiring be careful never to let foreign matter from the above module such as wiring scraps get inside the module If something goes in get rid of it 4 The module installation screw should be kept within the following range Screw Locations Tightening Torque Range Module installation screws M4 screws 78 to 118Nycm ...

Page 9: ...FF PC N ST PRM ON REM MNG D PRM ST SIZE 8 16 32 64 LB LW SIZE 2 4 6 8k CRC OVER AB IF TIME DATA UNDER SD RD PW PC REM SW E M S E PRM E R E CPU R W RUN MNG S MNG DUAL D LINK T PAS F E E R R O R L R DISPLAY F L R L NETWORK NO X100 X10 X1 OFF ON FRONT SIDE SW 1 2 3 4 5 6 7 8 GR NO ST NO X10 X1 MODE MODE 0 ONLINE A R 2 OFFLINE 1 2 3 4 5 7 8 6 E 6 D 5 C 4 B 3 A 2 9 1 8 0 F 7 F RD R SD Display of hardwa...

Page 10: ...m sub control station and the one of the host received from control station R E Reverse loop R LOOP is faulty Cause Power off of adjacent station cable disconnection no connection etc The position of switch for the display switch over of 6 is valid when it is on the right side CPU R W Communicating with CPU CRC Error detected in code check of receive data Cause Timing at which station sending data...

Page 11: ...The SW E LED turns ON Mode setting factory setting at time of shipping 0 Mode Name Contents 0 Online automatic online return effective Data link with automatic online return effective 1 Not used Setting to this turns on the SW E LED 2 Offline Disconnects the host station 3 Forward loop test Checks the forward loop of the whole network system 4 Reverse loop test Checks the reverse loop of the whole...

Page 12: ... common Default Parameters 4 Number of stations OFF ON OFF ON 5 Valid when SW3 is ON OFF 8 stati ons OFF 16 stati ons ON 32 stati ons ON 64 stati ons 6 B W number of general point OFF ON OFF ON 7 Valid when SW3 is ON OFF 2k points OFF 4k points ON 6k points ON 8k points 7 1 Conditions setting switch OFF ONSW 1 2 3 4 5 6 7 8 2 SW 1 2 3 4 5 6 7 8 OFF PC N ST PRM ON REM MNG D PRM ST SIZE 8 16 32 64 L...

Page 13: ...T b A1SJ71LP21GE AJ72LP25GE A1SJ71LP21GE IN RD SD RD SD OUT AJ72LP25GE IN RD SD RD SD OUT AJ72LP25GE IN RD SD RD SD OUT Optical module Optical fiber cable 3 When laying the optical fiber cable do not touch the fiber core of the cable connector or module connector or let dirt or dust collect on it If oil from the hands dirt or dust should adhere to the core the transmission loss will increase causi...

Page 14: ...est after wiring It might be generated that a baton abnormal passing cannot be generated when miswiring and the downed bureau which cannot do the loopback of an arbitrary bureau do the row again even by the reclosing of the power supply 7 Completely turn off the externally supplied power used in the system when connecting or disconnecting the cable ...

Page 15: ...16 32 64 LB LW SIZE 2 4 6 8k CRC OVER AB IF TIME DATA UNDER SD RD PW PC REM SW E M S E PRM E R E CPU R W RUN MNG S MNG DUAL D LINK T PAS F E E R R O R L R DISPLAY F L R L NETWORK NO X100 X10 X1 OFF ON IN FRONT SIDE OUT SW 1 2 3 4 5 6 7 8 GR NO ST NO X10 X1 MODE MODE 0 ONLINE A R 2 OFFLINE D C 4 B 3 9 8 0 F 7 F RD R SD R RD F SD 4 5 0 18 Unit mm in 1 Please confirm details to Mitsubishi Electric Sy...

Page 16: ...es Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852...