background image

 

 
 
 
 

User 
Manual Book 

Wall Chimney Hood 

 
 
 
 
 
 
 

Imola Seri  
CX 7310 L 

Modica Seri 
CX 7712 L,  
 

Diva Seri 
CX 9330, CX 6330, CX 9177 
CX 9157 
 
Ferrara Seri 
CX 9301, CX 6301 
 
Cesena 
CX 9156, CX 9106 
 

Forli Seri 
CX 9777, CX 9753, CX 9701 L  
 
 
Faenza Seri 
CX 9356 
 
Piazza Seri 
CX 9150, CX 6150, CX 7110 L 

Summary of Contents for Cesena Series

Page 1: ...od Imola Seri CX 7310 L Modica Seri CX 7712 L Diva Seri CX 9330 CX 6330 CX 9177 CX 9157 Ferrara Seri CX 9301 CX 6301 Cesena CX 9156 CX 9106 Forli Seri CX 9777 CX 9753 CX 9701 L Faenza Seri CX 9356 Piazza Seri CX 9150 CX 6150 CX 7110 L ...

Page 2: ...m to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach out to us if you need further assistance or other information via our Customer Care or our official website www modena com ...

Page 3: ...NTS PAGE Introduction Part 1 Safety Warnings 5 Part 2 Name of Parts 6 Part 3 Installation 8 Part 4 How to Use 18 Part 5 Maintenance 23 Part 6 Problems Solutions 25 Part 7 Precautions 25 Part 8 Specification 26 ...

Page 4: ... on gas stoves or other fuels The exhaust hood waste pipe should be separated with an air duct Regulations regarding the air exhaust must be met The unit is not intended to be used by persons including children with a physical sensory or mental disability or lack of experience and knowledge unless they have been given supervision or instructions concerning the use of the appliance by the person wh...

Page 5: ... other attributes are depending on the type of products 1 Control Panel 2 Cassette Aluminum Filter 3 Cassette Aluminum Filter Handle 4 Lamp 5 Main Chimney 6 Upper Connector Chimney 7 Circulation Hole CX 7712 The image is a general overview and is not necessarily the same as the product you receive Features and other attributes are depending on the type of products Part 2 Name of Parts ...

Page 6: ...s a general overview and is not necessarily the same as the product you receive Features and other attributes are depending on the type of products CX 9157 CX 9177 The image is a general overview and is not necessarily the same as the product you receive Features and other attributes are depending on the type of products ...

Page 7: ... on the wall and methods for installing bracket Notes Height distance are 65 75 cm except for CX 9753 type where the height distance is 35 40 cm For CX 9753 we recommend installation for use with a stove without the top cover Height Distance C can be shortened in accordance to the ceiling height Make a vertical line on the wall to its highest point or to an appropriate height on the center part of...

Page 8: ...ket I on the wall or on the screw head especially for CX 9753 Connect the exhaust system with the spigot flange if the exhaust hood will be operated in a ducting exhaust system Install the main chimney and the upper chimney on brackets I and II with the screws that already provided WORK METHOD MODENA exhaust hood has 2 principle of work Several things which require attention in installing the duct...

Page 9: ...ed CX 7110 L CX 7310 L CX 9156 CX 9301 CX 9356 and CX 9701 Preparations of installation If you have a waste pipe outside the exhaust hood can be connected using extraction duct enamel aluminum flexible pipe or a fire resistant material with an inner diameter of 150 mm see the following picture Before installation switch off the unit and unplug the power cord from the power socket Installation of t...

Page 10: ...Screw and tighten the bracket onto the wall with the screws screw plugs provided For inclined panel Model need to drill 4 x 8mm extra holes fixing screws screw plugs before installation Leave up the exhaust hood and hang onto the wall bracket hook Fix the one way valve to the air outlet of the exhaust hood Then attached the exhaust pipe into the one way valve as shown below Chimney installation Fo...

Page 11: ...fixing hole to the fixing screws as showed in below pictures Drill 2 8 mm holes to accommodate the plate II Screw and tighten the plate II into the wall with two screws provided Assembly the chimney into the unit and fix it with two screws For Tower model Put the inner chimney into upper chimney Then pulling out the upper chimney upwards Adjust to reach the height required Fix the lower chimney wi...

Page 12: ...the wall with two screws provided Assembly the chimney into the unit and fix it with two screws Installation Re circulating System If you do not have an outlet to the outside exhaust pipe is not required and the installation is similar to the one show in section Installation DUCTING EXHAUST System Activated carbon filter can be used to trap odors In order to install the activated carbon filter the...

Page 13: ...rom the hob surface to the underside of range hood 300 mm for electric hob 350 mm for gas hob If the instruction for the gas hob installation specified a greater distance this has to be taken into account NOTE Any installation above 700mm will compromise the performance of this range hood The total height of the hood is 660 mm In order to disassemble the protective cover smoothly the distance betw...

Page 14: ...ansion tubes to fix the bracket onto the wall 4 Install the flow exit to the hood and follow by connecting the flexible exhaust duct to the flow exit 5 Strengthened the connection between the flow exit and the flexible exhaust duct with screws 6 Lift and hang the hood to the wall bracket and please ensure it sits firmly on thebracket 7 Direct the other end of the flexible exhaust duct to the outle...

Page 15: ...s Height distance are 35 45 cm For CX 7712 L we recommend installation for use with a stove without top cover Height Distance C can be shortened in accordance with the ceiling height Make a vertical line on the wall to its highest point or to an appropriate height on the center part of the area where the vent hood is to be installed Make a horizontal line at H cm distance from the stove to mark th...

Page 16: ...meter of 150 mm Several things which require attention in installing the ducting system vent hood 1 Carbon filter must be removed Only use the aluminum filter 2 If the hood is to be installed in a multi storied building or an apartment consult with the person in charge of the building apartment prior to installing the exhaust system 3 Hood with ducting system should be used in an open air room wit...

Page 17: ... be wash or recycle Maximum use of carbon filter is 120 hours of use and must be replaced afterwards Carbon filters should not be exposed to heat CX 9150 CX 9330 and CX 9753 Connect the power cord with a power socket Slide or press the motor speed button to turn the hood on or off as shown in the following image Notes Adjust the motor speed of the exhaust hood according to the thickness of smoke s...

Page 18: ...ON To Set the Usage Time To Turn On Off the Light To Adjust the Speed Level Low Medium High To Turn On Off the Hood If the button is pressed the unit will work in which the motor speed depending on the last setting Clock Setting The default setting for the time when it was first turned on is 12 00 PM If the power is not connected or cut off the unit will return to the initial setting is 12 00 and ...

Page 19: ...ill not working if it reached the lower limit of 00 The addition value by every touch is 01 3 Press the button one more time to finish the Clock s Setting Setting the Timer The Timer can be set when the motor or lamp is on Timer duration is set in three periode 5 minutes 15 minutes 30 minutes Cancel 1 To set the timer touch the button once for 5 minutes twice for 15 minutes thrice for 30minutes fo...

Page 20: ...ndition that causes a high amount of smoke and steam Buttons to turn on off lights TOUCH button type Touch control After plug in power it will automatically sets in standby mode Timer s Button Times setting keep pressing it while in standby mode to enter time setting hour display will flash press or to set the time Press to change into minute setting press or to set the time press again or wait 10...

Page 21: ... direct contact between the stove being turned on and the exhaust hood To get the optimal filtering a exhaust hood should be turned off 20 30 minutes after cooking is finished CX 9157 CX 9177 dan CX 9777 Operating Instructions Confirm that when the hood is installed plug in the power cord and the hood sends out a drip sound indicating that the power is connected Please use the following methods fo...

Page 22: ...s the Lighting keys for 3 seconds to enter the cleaning lock screen state and press 3 seconds to exit the cleaning lock screen The indicator light of strong key keeps flickering the hood enters the state of cleaning lock screen Press the strong key for 3 seconds to exit the lock screen The buzzer whistles and the panel close Clock display In the state of clock display press the power key for a lon...

Page 23: ... vent hood according to the thickness of smoke steam generated by the cooking process CAUTION Avoid direct contact between the vent hood and open flames from the stove To obtain optimum filtering result turn off the vent hood 20 30 minutes after having finished cooking MODENA exhaust hood specifically designed for a long term use so that it does not require complicated maintenance However there ar...

Page 24: ...s no longer capable to absorb the cooking odor Remove the aluminum filter first Remove the carbon filter by pulling the hook for square shaped filter or rotating it for round shaped filter Install the new carbon filter Reinstall the aluminum filter ATTENTION Carbon filter cannot be washed and must be replaced with a new one in accordance with the description above Cleaning oil container Clean the ...

Page 25: ...or stops working after a while Safety thermal regulator is active The vent hood is installed too close to the stove Air circulation is not optimal Contact MODENA Service Center Make sure the hood is turned on after a while to allow the air around the cooking area to circulate properly and make sure the hood is turned off after this process Periodically inspect the filter and oil reservoir Make sur...

Page 26: ... 1000 900 900 Dimention P x L x T mm 895 x 400 x 770 1150 900 x 500 x 580 1060 900 x 500 x 580 1060 MODEL CX 7310 L CX 7110 L CX 9301 Type Wall Chimney Wall Chimney Wall Cabinet Material Metal tempered glass Stainless tempered glass Stainless Cabinet Color Black Black Stainless Front Panel Color Black Black Black Motor 1 Turbo 1 Turbo 1 Turbo Lamp LED LED LED Fan Speed 3 3 3 Ionizer Germinator No ...

Page 27: ...L CX 9777 CX 9177 CX 9157 Type Wall Chimney Wall Chimney Wall Cabinet Material Stainless Steel tempered glass Stainless Steel tempered glass Stainless Steel tempered glass Cabinet Color Stainless Stainless Stainless Front Panel Color Black Black Black Motor DC Motor DC Motor DC Motor Lamp LED LED LED Fan Speed 3 3 3 Ionizer Germinator No No No Fitler Type Stainless steel Mesh Filter Stainless stee...

Page 28: ...eel Tempered Glass Stainless Steel Tempered Glass Stainless Steel Cabinet Color Stainless Stainless Stainless Front Panel Color Black Stainless Stainless Motor 1 Turbo 1 Turbo 1 Turbo Lamp LED 2 LED 2 LED Control Panel Push Button Push Button Push Button Fan Speed 3 3 3 Filter Type Cassette Aluminum Filter Carbon Filter Filter Vit C Cassette Aluminum Filter Carbon Filter Filter Vit C Cassette Alum...

Page 29: ...12 20 ...