background image

 
 
 
 

Operating Instructions & Parts Manual

 

 

READ AND SAVE THESE INSTRUCTIONS 

 
WARNING 

– TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

 
A) Use this unit only in the manner intended by the manufacturer.  If you have questions, contact the manufacturer.  
 
B) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 
from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel. 

 

Read carefully before attempting to assemble, install, operate or maintain

 

the product described.  Protect yourself and 

others by observing all safety information.  Failure to comply could result in personal injury and/or property damage. 

Retain instructions for future reference.

 

 
 

MODULE-AIR 

AF-24xx SERIES

 

AIR CLEANER

 

(AF-2423, AF-2433, & AF-2453)

 

 

Description

 

This 8500 CFM Air Cleaner was designed for use as ambient air filtration 
where airborne particles are prevalent.  The air cleaner consists of 4 intakes 
and one exhaust, one motor, one blower, electrical components and a 
riveted sheet metal housing. 
These units are about 410 pounds, and cannot be handled or  
transported without the help of lifting tools. 
It is recommended that you consult a professional electrician prior to 
installing this product.  If this Air Cleaner is to be used in an application that 
presents a potential fire hazard, a fire protection expert should be 
consulted. 

 

Unpacking

 

 

The machine should be unpacked carefully.  Check if the machine and 
components are consistent with those indicated in the Parts List.  If any 
doubt arises or if parts appear to be missing, contact your dealer. 

                                   

MOTOR OPTIONS:

 

MODEL 

NUMBER

 

VOLTAGE

 

HP

 

Hz

 

AMP DRAW

 

AF-24xx230 

230V THREE PHASE 

5 HP 

60 

12.6 

AF-24xx480 

480V THREE PHASE 

5 HP 

60 

6.3 

AF-24xx575 

575V THREE PHASE 

5 HP 

60 

BLOWER:

 

MODEL 

NUMBER

 

 

TYPE:

 

 

CFM:

 

 

(ALL) 

FORWARD INCLINE 

 8500 

 

    
   SOUND LEVEL:  

68 Db(A)

 

 

 
 

APPROXIMATE WIEGHT

 

AF-24xx 

410 lbs 

Summary of Contents for AF-24 Series

Page 1: ...2433 AF 2453 Description This 8500 CFM Air Cleaner was designed for use as ambient air filtration where airborne particles are prevalent The air cleaner consists of 4 intakes and one exhaust one motor one blower electrical components and a riveted sheet metal housing These units are about 410 pounds and cannot be handled or transported without the help of lifting tools It is recommended that you c...

Page 2: ...ow Take the unit down and place it on a level surface that allows access to the door panel of the Main Housing To access the motor pulleys and belt Remove the door panel by removing 16 20x1 1 4 bolts with a 3 8 socket Troubleshooting Chart Symptom Possible Cause s Corrective Action Excessive belt noise 1 Belt is loose 1 Remove door panel loosen nuts that fasten motor turn adjustment screw until op...

Page 3: ...dusts like aluminum magnesium and other materials NFPA also has standards that cover other dusts like grain and plastics ect For guidelines on determining which precautions should be taken please refer to NFPA 497 There may be other specifications that apply for your particular application so please consult current NFPA standards that may be acquired at NFPA 1 Batterymarch Park Quincy MA 02269 1 8...

Page 4: ...improper methods structural failure or inadequate supports Installation Diagram on PG 5 Installation methods will depend upon the style of intake options that were selected when your system was ordered The following is a basic guide line and only a suggestion A professional installer should be consulted One option is to mount Uni Strut to the building structure dangle threaded rod through the hole...

Page 5: ...Module Air Revised 6 10 2014 ...

Page 6: ...Module Air Revised 6 10 2014 480 V Three Phase 60Hz Three phase motor L1 L2 L3 OL OL OL T1 T2 T3 3 phase power ...

Page 7: ...Module Air Revised 6 10 2014 ...

Page 8: ...fective in material or workmanship can be shipped prepaid to MODULE AIR or authorized service facility in which case a determination will be made whether to repair or replace the component MODULE AIR is not responsible for shipping costs related to sending replacement parts to customer or customer returning parts to MODULE AIR for inspection All freight costs incurred by warranty claims are the re...

Reviews: