AT 2200 Air Head Crimp Tool 

Doc. No. 64005-1500 

Release Date: 01-16-03 

UNCONTROLLED COPY

 

Page 1 of 7 

Revision: C 

Revision Date: 01-10-06 

 

Air Powered Crimp Tool Head

 

Operating Instruction Sheet And Specifications 

Part No. 64005-1500 

Eng. No. AT 2200 

(Replaces 19283-0012) 

FEATURES 

 

Œ 

Quick change tool head for the 19279-0001 (AT-200) 

Œ 

Tooling kit is interchangeable with other kits in the 64001 and 64003 series 

Œ 

A precision user-friendly terminal locator wire stop holds terminals in the proper crimping position 

Œ 

Insulation crimp adjustment allows a precise insulation crimp. To meet or exceed the requirements of UL, CSA and Military Class II 

Œ 

Pneumatic powered crimp tools help reduce fatigue and discomfort from repetitive manual crimping 

Œ 

Single color-coded crimp pocket eliminates the possibility of using the wrong pocket 

 

SCOPE 

AviKrimp

/InsulKrimp

 Terminals 10 - 12 AWG, (Rings, Spades, Splices, Hooks, Snap Spades, Flanged Spades, Wire Pin 

Terminals and also 3 to 4 Way Connectors).  Also terminates ends of step down butt splice 10 - 12 to 14 - 16 AWG.  This tool head is 
intended for use in the 19279-0001 (AT-200) either hand held or with optional bench adapter 19078-0307 (ATBA) and foot switch. 
 

Testing

 

Mechanical 

The tensile test, or pull test, is a means of evaluating the mechanical properties of the crimped connections.  The following charts  
show the UL specifications for various wire sizes.  The tensile strength is shown in pounds and indicates the minimum acceptable 
force to break or separate the terminal from the conductor. 
 

Wire Size  (AWG) 

*UL - 486 A 

*UL – 486 C 

16 N/A 

15 

14 N/A 

25 

12 70 

35 

10 80 

40 

*UL - 486 A - Terminals (Copper conductors only) 

*UL - 486 C - Butt Splices. 

 

The following is a partial list of the product part numbers and their specifications that this tool is designed to run.  We will be adding to 
this list and an up to date copy is available on www.molex.com. 
 

Wire Size: 10 – 12 AWG 5.00 – 3.00 mm² 

Terminal 

Wire Strip Length  Insul. Dia. Max. 

Terminal No. 

Eng No. (REF) 

In 

mm 

In 

mm 

19070-0119 C-228-06X  .375 9.53 .250 6.35 
19070-0121 C-228-08X  .375 9.53 .250 6.35 
19070-0123 C-228-10X  .375 9.53 .250 6.35 
19070-0130 C-230-10X  .375 9.53 .250 6.35 
19070-0132 C-230-14X  .375 9.53 .250 6.35 
19070-0136 C-230-56X  .375 9.53 .250 6.35 
19070-0143 C-236-06X  .375 9.53 .250 6.35 
19070-0145 C-236-08X  .375 9.53 .250 6.35 
19070-0150 C-240-14X  .375 9.53 .250 6.35 
19070-0153 C-240-38X  .375 9.53 .250 6.35 

Wire Size: 10 – 12 AWG 5.00 – 3.00 mm² 

Terminal 

Wire Strip Length  Insul. Dia. Max. 

Terminal No. 

Eng No. (REF) 

In 

mm 

In 

mm 

19070-0155 C-240-56X  .375 9.53 .250 6.35 
19073-0145 C-801-12  .375 9.53 .225 5.72 
19073-0147 C-801-12X  .375 9.53 .250 6.35 
19073-0160 C-828-06  .375 9.53 .225 5.72 
19073-0163 C-828-06X  .375 9.53 .250 6.35 
19073-0165 C-828-08  .375 9.53 .225 5.72 
19073-0168 C-828-08X  .375 9.53 .250 6.35 
19073-0170 C-828-10  .375 9.53 .225 5.72 
19073-0173 C-828-10X  .375 9.53 .250 6.35 
19073-0179 C-830-10  .375 9.53 .225 5.72 

Summary of Contents for AT 2200

Page 1: ...how the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate the terminal from the conductor Wire Size AWG UL 486 A UL 486 C 16 N A 15 14 N A 25 12 70 35 10 80 40 UL 486 A Terminals Copper conductors only UL 486 C Butt Splices The following is a partial list of the product part numbers and their specificati...

Page 2: ... 5 72 Wire Size 10 12 AWG 5 00 3 00 mm Terminal Wire Strip Length Insul Dia Max Terminal No Eng No REF In mm In mm 19115 0041 C 8710 05 375 9 53 225 5 72 19115 0042 C 8710 06 375 9 53 225 5 72 19115 0046 C 8718 08 375 9 53 225 5 72 19115 0048 C 8719 10 375 9 53 225 5 72 19127 0086 C 817 08 375 9 53 225 5 72 19127 0089 C 817 10 375 9 53 225 5 72 19139 0060 C 8105 08 375 9 53 225 5 72 19144 0037 C 2...

Page 3: ...3 way and 4 way terminals the locator must be removed Splices must be visually aligned with the tooling inside the insulation crimp See Figure 4 Note Whenever crimping without the locator make sure the seam of the terminal is oriented up or down in the tool if using unbrazed product as this will provide higher pull force values 6 If the insulation part of the crimp needs to be adjusted first disco...

Page 4: ...n 4 When tool is not in use store the tool in a clean dry area Tool Calibration A Certificate of Calibration see last page was supplied with the tool To recalibrate this tool pin gauge measurements should be taken in each conductor nest and compared to this chart The tool should be lubricated prior to recalibration to ensure consistent measurements Wire Range X Dimension Conductor Crimp Nest Color...

Page 5: ...rom an Industrial supply company such as MSC 1 800 645 7270 Item Order No Description Quantity 64005 1500 Crimp Tool Head Fig 6 1 64005 0000 Basic Air Tool Head 1 2 64001 1575 Locator Assembly 1 3 64001 1570 Tooling Kit 1 Tooling Kit Only 4 64001 1502 Conductor Punch 1 5 64001 1501 Conductor Anvil 1 6 64001 1504 Insulation Punch 1 7 64001 1503 Insulation Anvil 1 8 N A 4 mm Dia by 5 0 mm Lg Roll Pi...

Page 6: ...ed Item Order No Description Quantity 64005 0000 Basic Air Tool Head Fig 7 1 64005 0103 Nose Guard 1 2 64000 0077 Repair Kit Springs Rods Pivots Rings and Washers 1 3 N A M4 by 12LG Freedrive Pan Head Screw 1 4 N A M4 by 30LG Freedrive Pan Head Screw 1 5 N A 3 16 by 3 8 Long Dowel Pin 1 The following purchased parts are available from an Industrial supply company such as MSC 1 800 645 7270 ...

Page 7: ...t Nests or Slug height if the nest is the F Crimp style Range Conductor Nest 1 ____________ Actual ____________ Range Conductor Nest 2 ____________ Actual ____________ Range Conductor Nest 3 ____________ Actual ____________ Technician _______________________ Date of Calibration __________________ Calibration should be done every 5 000 cycles or 3 months Tools should be lubricated during this opera...