background image

INSTALLATION INSTRUCTIONS

Molex Premise Networks

Corporate Headquarters

Tel: 1 866 733 6659

www.molexpn.com

European

Headquarters

Tel: 44 (0) 1489 572111

www.molexpn.co.uk

Pac Rim

 Headquarters

Tel: 61 3 9971 7111

www.molexpn.com.au

Molex 

Incorporated

Tel:  630 969 4550

www.molex.com

MOLEX PREMISE NETWORKS

This information is correct as at the time of publication, specifications are subject to change.

Doc. # AS-18700-002, Rev C 

Form #  315-234 

Rev. Date: July 2008 

SAP # 187000294  

Shielded DataGate Jack

1. Termination 

Tool

 

110 termination tool set on low impact.

Terminated with F/UTP cable .............................................................................................page 1-3
Terminated with S/FTP cable .............................................................................................page 4-5
Terminated with U/FTP cable .............................................................................................page 6-8

1

2c. 

90° cable entry.

2d. 

Remove can cut-out for 90° cable entry.

2. 

Preparation and termination (F/UTP)

2a.

 

Slide rear can and plastic cable clamp on to cable.

2b. 

180° cable entry.

TERMINATED WITH F/UTP CABLE

Summary of Contents for Shielded DataGate

Page 1: ...as at the time of publication specifications are subject to change Doc AS 18700 002 Rev C Form 315 234 Rev Date July 2008 SAP 187000294 Shielded DataGate Jack 1 Termination Tool 110 termination tool...

Page 2: ...information is correct as at the time of publication specifications are subject to change 2e Remove 100mm of cable sheath Cut central separator back to sheath Cut cellophane wrap back to sheath Wrap...

Page 3: ...correct as at the time of publication specifications are subject to change 3 Fitting Can and Securing Cable F UTP 3a Slide the rear can over the front can Ensure that the two halves are latched togeth...

Page 4: ...WORKS This information is correct as at the time of publication specifications are subject to change 4d Wiring Map 4e Terminate cable ensuring that enough twisted braid is available to make contact wh...

Page 5: ...olex Incorporated Tel 630 969 4550 www molex com MOLEX PREMISE NETWORKS This information is correct as at the time of publication specifications are subject to change 5 Fiting Can and Securing Cable S...

Page 6: ...at the time of publication specifications are subject to change 6d Wrap the foil around the sheath with the conductive side of the foil facing outward Trim off excess foil 6 Preparation and terminati...

Page 7: ...com MOLEX PREMISE NETWORKS This information is correct as at the time of publication specifications are subject to change 6e Wrap drain wire around foil and tighten leaving a length of drain wire ava...

Page 8: ...ww molex com MOLEX PREMISE NETWORKS This information is correct as at the time of publication specifications are subject to change 7 Fitting Can and Securing Cable U FTP 7a Slide the rear can over the...

Reviews: