background image

2

Connect to Power

Use the supplied connector to connect to the AC 

supply according to the diagram below. Use 16 

AWG wire for Line (L) and Neutral (N). Use 14 AWG 
for Earth Ground (G).

AC input voltage must be 

selected by switch.

Check

 input voltage avoiding damage 

before 

power on!

80VAC<Input AC Voltage<135VAC: 

set the switch on 115V Status
135VAC<Input AC Voltage<265VAC:                      

set the switch on 230V Status

The SRAC2 has an internal 5A fast acting fuse. 

Care should be taken when working with high voltages.

4

Selecting the Motor

Each position of the 16-bit rotary selects a different motor, automatically setting the configuration parameters 
in the drive. The SRAC2 drive comes programmed with up to 16 typical motors as factory 
defaults. Drives can be customized with specially selected motors when required. Available 
options are listed on the drive label. Each motor in the loaded database has unique settings to 
optimize the anti-resonance. 

If the motor selection is changed, the drive power supply will need to be cycled.

3

Yellow A-

Black A+

Black A+

6 LEAD

MOTOR

Green NC

B+
Red

B-
White

NC
Blue

D

Black A+

4 LEAD

MOTOR

Green A-

White

White A

Brown

Green

Yellow C

Gray B

Pink
Blue

Red D

Green

Brown

Yellow

Gray

Blue

Red

Pink

C

Red B+

Blue B-

8 LEAD

MOTOR

8 LEAD

MOTOR

4-Lead Biploar Motor

6-Lead Center Tap Connected

Yellow NC

6 LEAD

MOTOR

Green A-

B+
Red

NC
White

B-
Blue

6-Lead Series Connected

8-Lead Series Connected

8-Lead Parallel Connected

Connecting to a Motor

Connect the drive to the motor. Four lead 

  motors can be connected
  in only one way. If using a 
  non MOONS’ motor, 
  consult the motor specs 
  for wiring information.

1

Requirements

To use the SRAC2 Step Drive, the following items 
are needed:

•  Universal AC input of 80 to 265 VAC
•  AC input voltage must be selected by switch
•  Pulse & Direction signal 
•  A compatible step motor

SRAC2

AC Input Step Motor Drive

Quick Set-Up Guide

LED

OUT-
OUT+
EN-
EN+
DIR-
DIR+

STEP+

SW12

SW11

SW10

SW9

STEP-

Motor Selection Switch

I/O Connector

Selection Switch

Motor Connector

Power Connector

SW8

SW7

SW6

SW5

SW4

SW3

SW1

B-
B+
A-
A+

SW2

N

L

Earth Ground (green)

Neutral (white)

Line-hot (black)

Reviews: