INSTRUCTIONS
.
MODEL M-60R
SUB-MICRONIC COMPRESSED
AIR FILTER w/ REGULATOR
580 CARNEGIE STREET 1-800-227-2822
MANTECA, CA 95337 FAX 209-239-5114
www.motorguard.com
Rev 19/19
33176
The Motor Guard M-60R combines a sub-micronic compressed air filter with a precision true-diaphragm regulator and gauge for a powerful point-of-use
air preparation unit.
FEATURES
M-60
Sub-Micronic Compressed Air Filter designed for
installation at to the point of use. Removes particulates,
condensed moisture and oil aerosols down to an
incredible .01 microns in size and absorbs large
quantities of moisture and oil. Uses (1)
M-723
replacement element.
MHT-7300
High-capacity, true diaphragm regulator
designed to set and hold pressure over a wide range of
flows and conditions. High-visibility, multi-scale pressure
gauge features a scratch and solvent resistant glass
lens. Large, ergonomic adjustment knob locks to hold
pressure setting.
SPECIFICATIONS
Port Size:
1/2NPT
Nominal Filtration Rating:
.01 Microns
Nominal Airflow Rating:
100 SCFM
Maximum Inlet Pressure:
125 PSIG
Outlet Pressure Range:
2-125 PSI
Operating Temperature Range: 40-120 °F
Install unit at or near point of use with at least 20 feet of supply line between unit and compressor. Failure to maintain this distance will cause excessive
water vapor to pass through unit. Unit is designed for installation in a 1/2" line; use appropriate fittings for installation in other line sizes. Apply pipe
thread compound to male thread connections. Before installing unit, relieve upstream pressure completely. Install unit level and in direction of airflow as
noted. Unit should be mounted to a rigid structure and should not be supported by the supply line.
WARNING: This product is intended for use in industrial compressed air systems only. Do not install where pressures or temperatures can
exceed those listed above.
Before pressurizing, be T-Handle is fully hand tightened by turning clockwise. Pressurize slowly to avoid high-pressure surge.
Open service valve (2) fully so that handle is parallel to inlet pipe. Turn knob on regulator clockwise to increase air pressure, counter-clockwise to
decrease. To reduce pressure setting, first reduce pressure to a setting lower than desired, then increase to the desired setting. Push knob up firmly to
lock and prevent accidental adjustment.
Inspect daily for leaks.
Regulator should be disassembled, cleaned and serviced periodically.
INSTALLATION
.
OPERATION
.