background image

NX-7510/NX-7520/NX-7530 Series

Integrated Services Platform

Installation Guide

Summary of Contents for NX-7510 Series

Page 1: ...NX 7510 NX 7520 NX 7530 Series Integrated Services Platform Installation Guide ...

Page 2: ...2 NX 7510 NX 7520 NX 7530 Series Integrated Services Platform MOTOROLA SOLUTIONS and the Stylized M Logo are registered in the US Patent Trademark Office Motorola Solutions Inc 2014 All rights reserved ...

Page 3: ...500 Series Services Platform 11 2 2 NX 7500 Series Power Supply Installation 12 2 3 NX 7500 Series NMC Installation 13 2 4 NX 7500 Series SFP Installation 14 2 5 NX 7530 Disc Drive Assembly Replacement 15 3 0 Specifications 16 3 1 Physical Specifications 16 3 2 Environmental Specifications 16 3 3 Power Specifications 16 4 0 Regulatory Information 17 4 1 Radio Frequency Interference Requirements FC...

Page 4: ...4 NX 7510 NX 7520 NX 7530 Series Integrated Services Platform 5 0 Motorola Solutions Support Center 21 6 0 NX 7500 Series China ROHS Compliance 22 ...

Page 5: ...rvey reports and verify correct equipment installation before connecting the appliance to its power source Remove jewelry and watches before installing this equipment Verify the unit is grounded before connecting it to the power source Verify any device connected to this unit is properly wired and grounded Connect all power cords to a properly wired and grounded electrical circuit Verify the elect...

Page 6: ...s Platform ships with the following NX 7500 series Integrated Services Platform Console cable Rack mount brackets NX 7510 NX 7520 NX 7530 Integrated Services Platform Installation Guide this document 1 4 1 NX 7500 Series Accessories The following accessories are available for NX 7500 series Integrated Services Platform 2 port 10Gb Network Mezzanine Card NMC module for use with 10Gb SFP transceiver...

Page 7: ...ging any settings in the BIOS will void all warranty on the integrated services platform CAUTION To prevent the integrated services platform from overheating never install in an enclosed area not properly ventilated or cooled For proper airflow keep the front and back sides of the integrated services platform clear of obstructions and away from the exhaust of other equipment CAUTION The recommende...

Page 8: ...unting the NX 7500 series integrated services platform in a rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given when connecting the NX 7500 series integrated services platform to the supply circuit so that protection is provided to the NX 7500 series integrated services platform and supply wiring if any c...

Page 9: ...protection Be sure to use a surge protection device between the electricity source and the NX 7500 series integrated services platform Install an Uninterruptible Power Supply UPS A UPS provides continuous power during a power outage Some UPS devices have integral surge protection UPS equipment requires periodic maintenance to ensure reliability A UPS of the proper capacity for the data processing ...

Page 10: ...or the installation 1 Match the model number on the purchase order with the model numbers in the packing list and on the integrated services platform 2 Verify the contents of the box include the intended NX 7500 series integrated services platform and the included hardware matches the package contents Part Number Description NX 7510 100R0 WR NX 7510 base server appliance with single AC power suppl...

Page 11: ...onnect the Ethernet cables and connect the integrated services platform to the network 4 Using a standard RS 232 console cable connect the serial port on the integrated services platform to a serial port on a separate computer the configuration computer 5 On the configuration computer configure a terminal emulation program as follows 6 Apply power to the integrated services platform 7 When the pro...

Page 12: ...510 or NX 7530 integrated services platform 2 When installing a second power supply in an NX 7510 or NX 7530 integrated services platform remove the blank cover from the back 3 Press the locking latch to lock the power supply in place 4 Plug the power cord into the power supply 5 Observe that the power supply light is illuminated to verify that the power supply is operating properly WARNING Power ...

Page 13: ...X 7500 7 Press the locking latch to lock the NMC in place 8 Reconnect all power cords to the integrated services platform WARNING Power down the integrated services platform and disconnect all power cords prior to installing or replacing the Network Mezzanine Card NMC CAUTION The NMC module uses lasers The lasers are compliant with the requirements for a Class 1 laser product and are inherently ey...

Page 14: ...orm SFP Installation The NX 7500 series integrated services platform supports use of SFP transceivers To install a SFP transceiver 1 Insert the SFP into the integrated services platform with the optical connector facing out and the slot connector facing down 2 Press the transceiver into the slot until it clicks into place NOTE SPF transceivers are keyed so that they can only be installed with the ...

Page 15: ...o the left and remove the hard drive from the drive bay 4 Firmly insert the new disc drive assembly into the drive bay 5 Push on the disc drive assembly until the lever locks in place 6 Apply power to the integrated services platform When the new disc drive assembly is properly installed the system rebuild will launch automatically This process may take up to two hours To monitor the progress of t...

Page 16: ... D 430 mm W x 42 mm H x 532 mm D Weight with 1 power supply NX 7510 19 lb 8 62 kg NX 7520 20 lb 9 07 kg NX 7530 21 lb 9 52 kg Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to 167 F 20 C to 75 C Operating Humidity 5 to 85 at 104 F 40 C Storage Humidity 5 to 95 RH non condensing Power Supply NX 7510 NX 7530 300 Watts 100 240V AC PSU 50Hz 60Hz NX 7520 300 Watts 48V DC Typica...

Page 17: ...e pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eq...

Page 18: ...rectives 2004 108 EC 2006 95 EC and 2011 65 EU A Declaration of Conformity may be obtained from http www motorolasolutions com doc Japan Voluntary Control Council for Interference VCCI Class A ITE Korea Warning Statement for Class A ITE Chinese Warning Statement for Class A ITE ሶቑ孔函ቒᇬ 䚕孔函 榊㽱椫 呹 尞Ⓟ 巿 ᨒ ᨅ ቑ 䄥 ቈሲኌ ኖ A 㔏嫢孔函ቊሼᇭሶቑ孔函ት ㄼ䜿 ቊ 䞷ሼቮቋ榊㽱ⰷ ትㆤሰ怆ሶሼሶቋሯሥቭቡሼᇭሶቑ ቒ 䞷劔ሯ拸 ቍ ት嶪ሽቮቫሩ尐㻑ሸቯቮሶቋሯሥቭቡሼᇭ ...

Page 19: ...produto visite http www motorolasolutions com recycling weee Nederlands Voor klanten in de EU alle producten dienen aan het einde van hun levensduur naar Motorola Solutions te worden teruggezonden voor recycling Raadpleeg http www motorolasolutions com recycling weee voor meer informatie over het terugzenden van producten Polski Klienci z obszaru Unii Europejskiej Produkty wycofane z eksploatacji ...

Page 20: ...ww motorolasolutions com recycling weee Slovenski Za kupce v EU vsi izdelki se morajo po poteku življenjske dobe vrniti podjetju Motorola Solutions za reciklažo Za informacije o vračilu izdelka obiščite http www motorolasolutions com recycling weee Slovenčina Pre zákazníkov z krajín EU Všetky výrobky musia byť po uplynutí doby ich životnosti vrátené spoločnosti Motorola Solutions na recykláciu Bli...

Page 21: ...rth in support agreements If you purchased your product from a Motorola Solutions business partner contact that business partner for support Customer Support Web Sites The Motorola Solutions Support Central Web site located at https portal motorolasolutions com Support US EN provides information and online assistance including developer tools software downloads product manuals and online repair re...

Page 22: ...棟摞尐㻑ᇭ 枏 㡴䤓㓏 ℶ 㦻嫷嫷䯉 ㄣ枍䤓䟄 ℶ 厌 扨K䓸德ᇭ㽷 㓏 ℶ 厌 厌ₜ 㦘㓏㦘㓏 䤓捷ↅᇭ This table was created to comply with China RoHS requirements 捷ↅ 䱿 Parts 㦘㹡㦘 䓸德㒥 侯 杔 Pb 㻭 Hg 柘 Cd ↆ杻 Cr6 䅃勣啾 PBB 䅃ℛ啾搩 PBDE 摠 捷ↅ Metal Parts X O O O O O 䟄恾㲰 Circuit Modules X O O O O O 䟄冕 䟄冕兓ↅ Cables and Cable Assemblies O O O O O O 㠨 勩 䓸捷ↅ Plastic and Polymeric Parts O O O O O O ⷵ ⷵ兓ↅ Optics and Optical Components O O O O O O 䟄㻯 Batteries O O O...

Page 23: ...Installation Guide 23 ...

Page 24: ...m MOTOROLA MOTO MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark Holdings LLC and are used under license All other trademarks are the property of their respective owners 2014 Motorola Solutions Inc All Rights Reserved MN000553A01 Revision A May 2014 ...