background image

 

 

P/N: 1802020003021 

*1802020003021* 

EDS-2005-EL/ELP Series   

Quick Installation Guide 

Moxa EtherDevice Switch 

Version 1.1, January 2021 

Technical Support Contact Information 

www.moxa.com/support 

 

 

 

 

 

 

 

 

 

 

 

 2021 Moxa Inc. All rights reserved. 

 

 

Summary of Contents for EDS-2005-EL Series

Page 1: ...0003021 1802020003021 EDS 2005 EL ELP Series Quick Installation Guide Moxa EtherDevice Switch Version 1 1 January 2021 Technical Support Contact Information www moxa com support 2021 Moxa Inc All rights reserved ...

Page 2: ...otection BSP Quality of Service QoS function via the DIP switches on the top panel The EDS 2005 EL ELP switches can be easily installed with DIN rail mounting as well as distribution boxes The DIN rail mounting capability and IP40 housing with LED indicators ensure that the plug and play EDS 2005 EL ELP switches are reliable and easy to use NOTE Throughout this Quick Installation Guide we use EDS ...

Page 3: ...Broadcast storm protection to prevent network devices from crashing Rugged Design Operating temperature range from 10 to 60 C IP40 rugged high strength case DIN rail or panel mounting ability WARNING The power for this product is intended to be supplied by a Listed Power Supply with output marked LPS and rated to deliver 12 to 48 VDC at a maximum of 0 11 A The DC jack should be used with an LPS un...

Page 4: ... 4 Panel Layout of EDS 2005 EL EDS 2005 ELP 1 Chassis ground screw 2 Terminal block for power input 3 DIP switch 4 Power LED 5 10 100 BaseT X Port 6 10 100 BaseT X Port LED 7 Port number 8 Model name ...

Page 5: ... 5 Mounting Dimensions EDS 2005 EL Series EDS 2005 ELP Series ...

Page 6: ...the bottom of the DIN rail kit and pull down Suggested Removal Method STEP 1 Pull down the latch on the DIN rail kit with a screwdriver STEP 2 Slightly pull the device forward and lift up to remove it from the mounting rail NOTE 1 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 2 The installation and the safety of any ...

Page 7: ...s than 3 5 mm in diameter as shown in the figure at the right NOTE Before tightening screws into the wall make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole shaped apertures of the Wall Mounting Plates Do not screw the screws in all the way leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws Once the screw...

Page 8: ...e maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the following items Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run...

Page 9: ...ront views of one of the terminal block connectors are shown here STEP 1 Insert the negative positive DC wires into the V V terminals STEP 2 To keep the DC wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector STEP 3 Insert the plastic terminal block connector prongs into the terminal block receptor which is locate...

Page 10: ...T X Ethernet Port Connection The 10 100BaseT X ports located on the EDS s front panel are used to connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports and also show cable wiring diagrams for straight through and cross over Ethernet cables 10 100Base T x RJ45 Pinouts MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal 1 Tx 2 Tx ...

Page 11: ... table below LED Color State Description PWR P Amber On Power is being supplied to power input PWR Off Power is not being supplied to power input PWR 10M 100M Green On When the port is active and links on 100 Mbps Blinking When the port s data is being transmitted at 100 Mbps Off When the port is inactive or link down Amber On When the port is active and links on 10 Mbps Blinking When the port s d...

Page 12: ...peak performance to be achieved when there is heavy traffic on the network Switching and Address Learning The Moxa EDS has an address table that can hold up to 8 000 node addresses which makes it suitable for use with large networks The address tables are self learning so that as nodes are added or removed or moved from one segment to another EDS automatically keeps up with new node locations An a...

Page 13: ...rload Current Protection Present Reverse Polarity Protection Present Mechanical Casing IP40 protection metal housing for EL Series plastic housing for ELP Series Dimensions W x H x D EDS 2005 EL 18 x 81 x 65 mm 0 7 x 3 19 x 2 56 in EDS 2005 ELP 19 x 81 x 65 mm 0 74 x 3 19 x 2 56 in Weight EDS 2005 ELP 56 g 0 12 lb EDS 2005 EL 105 g 0 23 lb Installation DIN rail Wall Mounting optional kit Environme...

Page 14: ... 14 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 Warranty 5 years ...

Reviews: