background image

Instructions for MS, MX, CT & SAH

Generator PC Board Replacement

mr

.

steam

®

For MrSteam Models MS90E, MS150E, MS225E, MS400E, MSSUPER1E, MSSUPER2E, MSSUPER3E,

MX4E, MX5E, MX6E, CT6E, CT9E, CT12E, CT15E, SAH3000, SAH4500, and SAH6000

1. MS, MX, CT & SAH Generator PC Board Replacement only to be performed after consultation with a MrSteam

Technical Service Representative.

2. REPAIR PROCEDURES MUST BE ACCOMPLISHED BY A QUALIFIED LICENSED ELECTRICIAN.

3. Use only MrSteam supplied replacement parts.

4. Follow all instructions in the Steam Generator Installation, Operation, and Maintenance Manual. This manual is

provided with the generator and is also available online at: www.mrsteam.com/technical.

GENERATORS WITH EXPRESS STEAM AND MAX GENERATORS REQUIRE JUMPER

ADJUSTMENT. FAILURE TO ADJUST JUMPERS MAY RESULT IN EQUIPMENT DAMAGE.

IMPORTANT NOTE:

As you follow these instructions, you will notice warning and caution symbols. This blocked information is

important for the safe and efficient installation and operation of this Generator. These are types of potential hazards that may occur
during this installation and operation:

states a hazard may cause serious injury or death if precautions are not followed.

signals a situation where minor injury or product damage may occur if you do not follow instructions.

IMPORTANT NOTE:

This highlights information that is especially relevant to a problem-free installation.

BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL BEFORE ATTEMPTING TO WIRE OR SERVICE THE PC BOARD.

WARNING

!

WARNING

!

CAUTION

!

CAUTION

!

PC Board Replacement

1. Turn off breaker to the steam

generator.

2. Unplug all connections to the

right side of the generator,
see figure 1.

3. Unscrew 2 screws on top cover

and remove top cover to the
generator, see figure 2.

Steam
Generator

Figure 1

Steam
Generator

Screws

Top Cover

Figure 2

1 2 3 4 5 6 7 8

Position 2
Position 1

Position 2
Position 1

1 2 3 4 5 6 7 8

Position 2
Position 1

1 2 3 4 5 6 7 8

Default Jumper

Express Steam Jumper Location

MX Generator Jumper Location

Location

• Move Jumper 4 to Position 1

• Move Jumper 6 to Position 1