background image

 

 

 

 

Limited Liability Company 

«NPK MORSVYAZAVTOMATICA» 

 

info@unicont.com 

www.unicont.com 

26E, Kibalchicha str., 192174,  
St. Petersburg, Russia 

Phone.: +7 (812) 622-23-10 
Fax: +7 (812) 362-76-36 

 
  
 
 

 

 

 
 

 
 
 
 
 
 
 
 

 

Batteryless telephone system  

with public address mode 

BLTS-1006 

 

Operating manual 

 

 
 

 

 

Summary of Contents for BLTS-1006

Page 1: ...NPK MORSVYAZAVTOMATICA info unicont com www unicont com 26E Kibalchicha str 192174 St Petersburg Russia Phone 7 812 622 23 10 Fax 7 812 362 76 36 Batteryless telephone system with public address mode...

Page 2: ...Description and operation of the system components 16 2 1 Description of the SC 16 2 2 Operation of the SC 21 3 Intended use 29 3 1 Operational limitations 29 3 2 Usage preparations 29 3 3 Use of the...

Page 3: ...nd storage 39 8 Disposal 40 Appendix A SPTA kit list 41 Appendix B Description of the SC 42 Appendix C Set of operation and maintenance documents 64 Appendix D Settings of SC 65 Appendix E Connection...

Page 4: ...System intended use technical service current repair storage and transportation as well as information on System components disposal Only those who have read and understood this document and those who...

Page 5: ...external signaling units EG Electric generator ES Energy storage LCD Liquid crystal display LIO LED Inductor on MTH Microtelephone headset OD Operational documentation OM Operating manual PA Public a...

Page 6: ...usoidal vibration within frequency range 1 200 Hz at the following oscilla tion amplitudes amplitude 1 mm for frequency range 2 0 13 2 Hz acceleration 0 7g 7 m sec2 for frequency range 13 2 100 0 Hz d...

Page 7: ...ection using external communication devices with throat microphones in environment with increased level of noise max 130 dB using individual means of hearing protection headset or intercom helmet f te...

Page 8: ...may be connected to power mains 24 18 36 V DC if required The System is connected to AC power mains via the System PSUs PS 103 PS 103 20 Signaling units are powered from external DC network 24 V or A...

Page 9: ...9 Version 0 1 Operating manual Figure 1 BTC user network...

Page 10: ...t marine atmosphere For the list of SC see Table 1 Table 1 The list of System components SC name Code Installation conditions Telephones PH2 1W For outside open spaces special spaces bridge central co...

Page 11: ...5 HS 5 HS 5AC Socket PB HS For outside open spaces special spaces bridge central control sta tions and accommodation areas IP56 S BLT Sound light signaling unit AL 24 R For outside open spaces specia...

Page 12: ...spaces special spaces bridge central control sta tions and accommodation areas IP56 Cord CE 1 5 For outside open spaces special spaces bridge central control sta tions and accommodation areas IP56 CE...

Page 13: ...lephones and telephones for pair communication and general list all see Figure 3 Figure 3 Network based on ommutator telephones and telephones c combined user network using any combination of ommutato...

Page 14: ...ed depending on power availability PA mode applied in case of available power mains the System users are powered from external power source Telephones and ommutator telephones in this mode operate as...

Page 15: ...on the model using bold face Arial size 14 All centres of legends are shifted for 2 5 mm to the right for convenient use reading Note single channel telephones do not have user line switches but they...

Page 16: ...ation with users of their own network in pair and general list all modes Use toggle switches to select users of the assigned lines All ommutator telephones are equipped with a telephone receiver corde...

Page 17: ...unted in cabinet BLTS2 BO 2 1 2 Telephone units Telephones PH2 1 type provide for pair communication in combination ommu tator telephone telephone or telephone telephone in BTC network two wire line o...

Page 18: ...eople s work and surrounding mechanisms The System includes helmets with throat microphones allowing for communication in means of respiratory protection The System includes the following external com...

Page 19: ...aling d relay unit type RBWSB that switches voltage to signaling units power circuits by control signals from telephone ommutator telephone It ensures call signaling in the following modes configure a...

Page 20: ...re auto matic load switching to standby power in case of main power failure 2 1 7 Metal cabinet Metal cabinet protects the SC installed on open deck against atmospheric precipi tation water wind low t...

Page 21: ...ator telephones and telephones controls Control element Description SC Call button To initiate a call if power mains available ommutator telephones and tele phones Reset call button To reset incoming...

Page 22: ...C2 SC provides for mixing and distribution of power voltage and voice signal communication device telephone receiver headset and intercom helmet AP and EG inductor For the functional diagram of ommuta...

Page 23: ...the same time it is supplied to USU and switches on light signaling of user line Once user line toggle switch is actuated on USU energy from user line is supplied to inputs VC1 and VC2 then power is s...

Page 24: ...Version 0 1 24 Batteryless telephone system with public address mode BLTS 1006 Figure 7 Functional diagram of ommutator telephone...

Page 25: ...ted in series with signaling unit in a line break or relay unit RBWSB During incoming call telephone ommutator telephone independently actuates signaling unit by CUESU signal or via relay unit RBWSB c...

Page 26: ...ree modes 2 1 4 Settings of call mode are carried out using jumpers JP1 and JP2 on the device board according to Table 5 Table 5 Settings of relay unit modes Jumper Set not set Function JP1 set call s...

Page 27: ...cation device and telephone ommuta tor telephone in two other positions closes the circuits at the same time in one extreme position toggle switch may be fixed and in another is shall be held during c...

Page 28: ...djustments belts at the top and under the chin regulate the convenient length Fix throat microphone on the neck using neck belt adjust its length Intercom helmets operation does not require any specia...

Page 29: ...lation while testing electrical cir cuits and insulation resistance 3 2 2 Visual check procedure Before switching the SC on the installer shall observe visually the cable integrity and initial positio...

Page 30: ...on device initiate a call and wait for the answer see 3 3 4 On the ommutator telephones prior to that set up a connection with called user switch on a toggle switch see 3 3 1 To initiate a call press...

Page 31: ...and hold it connection to telephone communication circuits Middle neutral position toggle is switched off To finish a call release PTT switch on the receiver and put the receiver down to holder If you...

Page 32: ...eration The S 1 results are registered in log of operation duty log S 2 is performed by the staff on equipment in operation S 2 results are registered to the System certificate 4 2 Safety features Whi...

Page 33: ...rity mechanical damage shall be absent 1 person 5 mins Table 9 CL 2 SC operability check Fault To do Man hours per 1 SC Check operation of telephones and om mutator telephones 1 check operation of Pow...

Page 34: ...ted in section 4 The scope of delivery of the System Certificate 2 check the quality of every SPTA kit item storage time SPTA kit shall be fully recompleted in case of its use according to 4 4 3 recom...

Page 35: ...ned back to the regular place of use a representative of the Manufacturer should be called in to draw up a damage claim Complete portable SPTA kit at regular place of use from basic SPTA kit 5 2 Safet...

Page 36: ...it con tact malfunction Replace the telephone ommutator telephone While rotating handle of electric generator call is not performed but LEDs In ductor on and Call are glowing Contact malfunction con n...

Page 37: ...ule or speaker Replace the telephone receiver Headset helmet malfunction Replace the headset helmet 6 2 Power supply units Control PSU operation by Power switch LED available power supply mains check...

Page 38: ...ternal signaling units do not operate at incoming call see similar problem in Telephones and ommutator telephones Fuse malfunction in signaling unit output circuit Replace the fuse No power mains Supp...

Page 39: ...overed cars multipurpose containers air transportation in sealed and heated compartments sea transportation in dry working areas The System must be transported in compliance with transportation rules...

Page 40: ...uthorities You can also send used up equipment unit to the manufacturer for its further disposal Proper disposal of the System components allows avoiding possible negative en vironmental and health im...

Page 41: ...mm 1 Fuse 2A 5 20 mm 1 Fuse 10A 5 20 mm 1 Bootlace terminal wire 2 5 mm2 100 Bootlace terminal crimper 0 4 4 0 mm2 1 Cross screwdriver PH1 1 Straight blade screwdriver blade width 3 5 mm thickness 0 6...

Page 42: ...ion in battery less communication systems Features operation in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be co...

Page 43: ...lic address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset or intercom helmet may be connected Technical specification...

Page 44: ...ommunication systems Features operation in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset and i...

Page 45: ...ion in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset or intercom helmet may be connected Techn...

Page 46: ...tems Features operation in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset or intercom helmet ma...

Page 47: ...peration in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset or intercom helmet may be connected...

Page 48: ...tem portable Features operation in BTC and public address modes controls backlight incoming call LEDs Inductor on LED external power LED external signaling units may be connected headset or intercom h...

Page 49: ...0 1 Operating manual Socket S BLT Description socket S BLT is designed to connect port able telephone PH2 5C PO Technical specifications operating temperature 40 55 C IP rating IP56 weight 0 8 kg Mou...

Page 50: ...06 Socket PB HS Description remote connection point for headset to telephone Features waterproof type equipped with waterproof connector with protective cover Technical specifications material aluminu...

Page 51: ...protect them against mois ture ingress Features equipped with a door to access to integrated SC and internal mounting panel door is equipped with a lock unlock mechanism and door stopper to keep it o...

Page 52: ...o relay unit RBWSB 24 and tele phones except portable ones RL 220 only to relay unit RBWSB 220 bracket at option Technical specifications power supply voltage for RL 24 24 V DC for RL 220 220 V AC 50...

Page 53: ...colours grey red delivered with cable glands cable is led using a hole knock out blank plug performed by stamping Technical specifications material impact resistant plastic red or grey power supply vo...

Page 54: ...relay unit RBWSB 24 and tele phones except potable L 220 only to relay unit RBWSB 220 cable is led using a hole knock out blank plug performed by stamping Technical specifications material polycarbona...

Page 55: ...amber blue green red yellow equipped with cable glands metal or plastic cable is led using a hole knock out blank plug performed by stamping Technical specifications material plastic impact proof powe...

Page 56: ...cted power 220 V or 24 V call reset button and incoming call LED supplies call signal to alarm units ensures call signaling after call is ended by user in modes continuous until reset with delay 10 se...

Page 57: ...hnical specifications headset type passive monophonic close talking response at frequency 300 3400 Hz idle run 16 dB module of microphone impedance at frequency 1000 Hz 600 120 roughness of close talk...

Page 58: ...ngle plug type connector Technical specifications headset type passive monophonic operating frequency range 150 7000 Hz close talking response at frequency 1000 Hz idle run 0 4 1 1 mV Pa module of mic...

Page 59: ...4M W TH 4M S C TH 4M W C TH 4M S AC TH 4M W AC Description external communication device Features freedom to move PTT switch type may be connected to telephones and ommutator tele phones CE type cord...

Page 60: ...ption external communication device of pub lic address substations to conduct talk back communica tion in environment of normal noise level Features freedom to move PTT switch type may be connected to...

Page 61: ...communication devices Features cable ends CE 1 5 CE 3 CE 5 CE 7 CE 10 plug connector cable ends CE 1 5BE CE 3BE CE 5BE CE 7BE CE 10BE bare crimped cable ends CE 1 5AC CE 3AC CE 5AC CE 7AC CE 10AC ang...

Page 62: ...quipment Features contacts to connect external signaling unit power failure signaling galvanic isolation of output power from power mains integrated automatic load switch to standby power source Techn...

Page 63: ...nect external signaling unit power failure signaling galvanic isolation of output power from power mains integrated automatic load switch to standby power source Technical specifications power supply...

Page 64: ...06 Operating manual Operating manual One per object Battery less communication equipment BTS 1006 Certificate Certificate One per object Battery less communication equipment BTS 1006 SPTA kit list Set...

Page 65: ...65 Version 0 1 Operating manual APPENDIX D SETTINGS OF SC Figure D 1 ommutator telephones PH2 12C PH2 20C Layout and assignment of terminals Controls...

Page 66: ...Version 0 1 66 Batteryless telephone system with public address mode BLTS 1006 Figure D 2 ommutator telephones PH2 5C PH2 10C Layout and assignment of terminals Controls...

Page 67: ...Hz jumper not set short interruptions Jumper set Call frequency 3 Hz jumper set long interruptions JP8 To control relay unit To connect signaling unit type RBWSB set the jumper Table D 2 Settings and...

Page 68: ...rsion 0 1 68 Batteryless telephone system with public address mode BLTS 1006 APPENDIX E CONNECTION OF THE SC Figure 1 Connection of ommutator telephone PH2 2C and portable ommutator telephone PH2 5C P...

Page 69: ...69 Version 0 1 Operating manual Figure E 2 Connection of ommutator telephone PH2 2C and portable ommutator telephone PH2 1...

Page 70: ...hone system with public address mode BLTS 1006 Figure E 3 Connection of external communication devices Table E 1 Description of HS headset wires with bare ends Pos Description Wire colour 1 brown 2 L...

Page 71: ...71 Version 0 1 Operating manual Figure E 4 Connection of socket PB HS...

Page 72: ...006 1 set Operation and technical documents 1 set SPTA kit 1 set ______________ The System s scope of delivery is specified at the stage of project design in the order list or stated in Supply contrac...

Reviews: