background image

Operating Manual

MSA HUB

SCBA Telemetry Version

Order No.: 10204590/02

MSAsafety.com

Summary of Contents for HUB

Page 1: ...Operating Manual MSA HUB SCBA Telemetry Version Order No 10204590 02 MSAsafety com ...

Page 2: ...sit https us msasafety com Trademarks This product incorporates Bluetooth wireless technology The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by MSA is under license Other trademarks and trade names are those of their respective owners MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil Jona Switzerland For your local MSA contacts pl...

Page 3: ...4 3 2 1 Multi Antenna 14 3 2 2 LRR Antenna 15 3 3 Ethernet Kit Installation MSA HUB Fireservice Standard only 17 4 Connectivity 19 5 Operation 21 5 1 LED Status Description 21 5 2 Firmware Update 21 5 3 Error Cases 22 5 4 Factory Reset 22 6 Decommission and Disposal 24 6 1 Decommission 24 6 1 1 MSA HUB Fireservice for Truck Installation with Wall Brackets 24 6 1 2 MSA HUB Fireservice for Truck Ins...

Page 4: ...The product must not be used if the function test is unsuccessful it is damaged a competent servicing maintenance has not been made genuine MSA spare parts have not been used Failure to follow this warning can result in serious personal injury or death Alternative use or use outside this specification will be considered as non compliance This also applies especially to unauthorized alterations to ...

Page 5: ...t LRR antenna for truck installation Antenna cable for LRR antenna 3 m 9 8 ft Quick Start Guide Truck Version MSA HUB Fireservice Standard MSA HUB Fireservice Standard device Industrial power supply Main power cable 5 m 16 4 ft Additional power cable 25 m 82 ft LRR antenna Quick Start Guide Standard Version The A2 Software can be downloaded via the MSA Software Product website at www MSAsafety com...

Page 6: ...ing terminal The device consists of a compact housing with five antenna connectors Wi Fi GPS LRR LTE 1 LTE 2 one Ethernet connector and one power connector A SIM card holder is included inside the housing lid When the device is installed and configured it can connect MSA devices to the Internet or intranet and transfer data The status LEDs show the respective connection status The device is intend...

Page 7: ...erminal 5 Status LEDs The device consists of a compact housing with three antennas and two connections Ethernet and power The Ethernet connector kit is available separately Part Number 10195741 A SIM card holder is included inside the housing lid When the device is installed and configured it can connect MSA devices to the Internet or intranet and transfer data The status LEDs show the respective ...

Page 8: ...vice may be damaged The device contains electrostatically sensitive components Adopt precautionary measures against electrostatic discharge during assembly Otherwise the device may be damaged The device must only be used with approved antennas The device must be disconnected from the power supply prior to assembly The power supply may be activated only after the device is fully assembled and conne...

Page 9: ... 8 Nm 1 3 ft lbf to fasten the wall brackets Part Number 10203364 at the back of the housing 4 Install device at the desired space When installing the device on a solid plain surface use four appropriate screws and apply a torque of 5 Nm 3 ft lbf 5 Close housing lid by tightening the lid screws with a torque of 1 5 Nm 1 ft lbf 6 Close right joints MSA HUB 9 GB 3 Assembly and Installation ...

Page 10: ...n nut with a torque of 1 2 1 5 Nm 0 9 1 ft lbf using a wrench SW14 The device is assembled 3 1 2 MSA HUB Fireservice for Truck Installation without Wall Brackets 1 Open housing by opening the right joints and unscrew the lid screws using a Torx T20 2 Optional Insert SIM card Place the SIM card into the SIM card holder NOTE Do not touch the circuit board assembly Observe electrostatic procedures MS...

Page 11: ...rque of 1 5 Nm 1 ft lbf 5 Close right joints 6 Optional Loosen grounding clamp a Insert grounding cable and re tighten grounding clamp with a torque of 2 Nm 1 5 ft lbf 7 If needed plug in and screw Ethernet plug with a torque of 0 4 Nm 0 3 ft lbf 8 Plug in power plug and screw union nut with a torque of 1 2 1 5 Nm 0 9 1 ft lbf using a wrench SW14 The device is assembled MSA HUB 11 GB 3 Assembly an...

Page 12: ... joints and removing the lid screws 3 Optional Insert SIM card Place the SIM card into the SIM card holder NOTE Do not touch the circuit board assembly Observe electrostatic procedures 4 Optional Use four screws to fasten the wall brackets to the housing MSA HUB 12 GB 3 Assembly and Installation ...

Page 13: ... the surface directly Use four appropriate screws and apply a torque of 5 Nm 3 ft lbf 6 Close housing lid by tightening the lid screws with a torque of 1 5 Nm 1 ft lbf 7 Close right joins 8 Optional Loosen grounding clamp a Insert grounding cable and re tighten grounding clamp with a torque of 2 Nm 1 5 ft lbf MSA HUB 13 GB 3 Assembly and Installation ...

Page 14: ...nto the rooftop a For the Multi antenna drill a hole with 31 mm 1 1 4 in diameter b For the LRR antenna drill a hole with 16 mm 5 8 in diameter NOTE Keep at least 20 cm 8 in distance between the antennas and from other metal parts 2 Clean the relevant surface on the roof from any dirt and dust 3 2 1 Multi Antenna 1 Remove lock nut spring lock washer and flat washer MSA HUB 14 GB 3 Assembly and Ins...

Page 15: ... with a torque of 50 Nm 36 ft lbf 7 Attach antenna cables to the relevant MSA HUB antenna connections NOTE GPS connection is for future use Label Connector 2G 3G 4G MIMO1 LTE 1 2G 3G 4G MIMO2 LTE 2 GPS Glonass GPS 2 4 5 8 GHz Wi Fi The Multi antenna is installed 3 2 2 LRR Antenna 1 Remove any burrs particularly on the roof under the side of the hole 2 Remove any paint in a narrow ring around the h...

Page 16: ...hole NOTE Metal to metal contact between the mounting surface and the mount is essential for best performance of the antenna 5 Re attach flat washer tooth lock washer and lock nut 6 Screw lock nut with a torque of 10 Nm 7 ft lbf 7 Attach the antenna cable to the LRR connection on the MSA HUB The LRR antenna is installed MSA HUB 16 GB 3 Assembly and Installation ...

Page 17: ... Standard only 1 Remove the sealing plug 2 Open housing by opening the right joints and removing the lid screws 3 Unscrew the four cover panel screws 4 Remove cover panel 5 Pass Ethernet plug through the hole MSA HUB 17 GB 3 Assembly and Installation ...

Page 18: ...thernet plug onto mainboard 8 Tighten lower nut with a torque of 0 4 Nm 0 3 ft lbf The cable is fixed within the cable gland 9 Close housing lid by tightening the lid screws with a torque of 1 5 Nm 1 ft lbf 10 Close right joins The Ethernet connector is installed MSA HUB 18 GB 3 Assembly and Installation ...

Page 19: ... for a network connection Connectivity functionality including monitoring configuration and registration is provided through A2 Software Refer to the A2 Software Manual on the Software Product website at www MSAsafety com Upon the initial setup connect the HUB provided network that is active by default The default connection settings are found on the HUB type label Figure 3 MSA HUB Type Label Fact...

Page 20: ... information regarding connectivity functionality including monitoring configuration and registration refer to the A2 Software Manual on the Software Product website at www MSAsafety com MSA HUB 20 GB 4 Connectivity ...

Page 21: ...lished 4 MSA Radio Connection On Off Off no user connected On at least one user connected 1 2 3 4 Error Case Blinking Any module is in error state see 5 3 Error Cases 1 2 3 4 Update process Flashing in repeat The device is loading and installing a software update 5 2 Firmware Update Regularly check for new updates by using the A2 Software Refer to the A2 Software Operating Manual on the MSA Softwa...

Page 22: ...cases in this table If the error persists please contact MSA Customer Support 5 4 Factory Reset If the device access password has been lost and no further access is possible a factory reset can be performed to reset all values to their defaults For default parameters see Table 2 Factory Reset Parameters NOTICE The device contains electrostatically sensitive components Adopt precautionary measures ...

Page 23: ...th a torque of 1 5 Nm 1 ft lbf 6 Close right joints The device is reset Table 2 Factory Reset Parameters Parameters Value Default Ethernet dhcp true disabled false Hostname ccimx6sbc WLAN configuration Client Hotspot disabled Hotspot WiFi client configuration previous connections to WLAN networks are deleted WiFi hotspot configuration ssid MSA HUB serial number key random on name plate MSA HUB 23 ...

Page 24: ...stallation with Wall Brackets 1 Unplug the power plug and remove Ethernet cable if present 2 Remove antenna cables 3 If a grounding terminal is used loosen grounding clamp and remove grounding cable 4 Reattach grounding clamp 5 Remove the wall bracket screws from the surface 6 Take the device off the installed place The device is decommissioned MSA HUB 24 GB 6 Decommission and Disposal ...

Page 25: ...T20 8 Remove the four screws and the wall brackets at the back of the housing 9 Close housing lid 10 Close right joints 6 1 2 MSA HUB Fireservice for Truck Installation without Wall Brackets 1 Unplug the power plug and remove Ethernet cable if present MSA HUB 25 GB 6 Decommission and Disposal ...

Page 26: ...ding clamp and remove grounding cable 4 Reattach grounding clamp 5 Open housing by opening the right joints and unscrew the lid screws using a Torx T20 6 Remove the screws from the surface 7 Take the device off the installed place MSA HUB 26 GB 6 Decommission and Disposal ...

Page 27: ...plug the power plug and remove Ethernet cable if present 2 If a grounding terminal is used loosen grounding clamp and remove grounding cable 3 Reattach grounding clamp 4 Remove the wall bracket screws from the surface 5 Take the device off the installed place The device is decommissioned MSA HUB 27 GB 6 Decommission and Disposal ...

Page 28: ... a Torx T20 7 Remove the four screws and the wall brackets at the back of the housing 8 Close housing lid 9 Close right joints 6 1 4 MSA HUB Fireservice Standard without Wall Brackets 1 Unplug the power plug and remove Ethernet cable if present MSA HUB 28 GB 6 Decommission and Disposal ...

Page 29: ...he right joints and unscrew the lid screws using a Torx T20 5 Remove the screws from the surface 6 Take the device off the installed place 7 Close housing lid 8 Close right joints The device is decommissioned 6 2 Disposal For disposal of the device and batteries local regulations are to be observed MSA HUB 29 GB 6 Decommission and Disposal ...

Page 30: ...vice firmware regularly see 5 2 Firmware Update Be aware of the Procedures for Handling Electrostatically Sensitive Electronic The device contains electrostatically sensitive components Do not open the device without using appropriate electrostatic discharge ESD protection The warranty does not cover damage caused by electrostatic discharges 7 1 Cleaning NOTICE Do not rub the device and never clea...

Page 31: ...8 Certification The Declaration of Conformity can be found under the following link https MSAsafety com DoC MSA HUB 31 GB 8 Certification ...

Page 32: ...range 20 C to 60 C Storage temperature range 20 C to 60 C Humidity 10 to 95 r H non condensing Degree of protection IP67 Power dissipation continuously PD 5 W peak PD 12 W Power supply Connector type Fireservice for Truck Installation M12 4 Pin A coded Fireservice Ethernet kit optional with cable bushing included Minimal input voltage 12 V DC Nominal input voltage 24 V DC Maximal input voltage 30 ...

Page 33: ...ft 10201801 SP LRR antenna for truck installation UK version 10213771 SP LRR antenna for truck installation EU US AUS version 10201944 SP Antenna cable for LRR antenna 3 m 9 8 ft 10205446 SP MSA HUB Fireservice Standard Description Part Number Industrial power supply 10202199 SP Power cable 25 m 82 ft 10203365 SP Main power cable 5 m 16 4 ft 10203573 SP LRR antenna EU 10202197 SP LRR antenna US 10...

Page 34: ...For local MSA contacts please visit us at MSAsafety com ...