background image

MSD Dual Delay Timer

PN 7563

 

Parts Included:

 

1 - Dual Timer Delay

WARNING: Before installing the MSD Timer, disconnect the battery cables. When dis-

connecting the battery cables, always remove the Negative (-) cable first 
and install it last.

The Dual Delay Timer allows you to activate two different circuits based on time (Channel 1 

and Channel 2). Each Channel can be used to activate (supply a ground source) or deactivate 

(remove  the  ground)  at  a  programmed  time.  The  time  is  adjustable  down  to  0.01-second 

increments. 

Note:  To  control  devices  that  require  over  2  amps,  a  relay  will  be  required.  MSD  offers  a 

SPDT 30 Amp/12 Volt DC as PN 8961 or a DPDT 30 Amp/12 Volt DC as PN 8960. 

Figure 4 Activating a Launch Retard and a 

Nitrous Solenoid. 

WIRING

RED

This is the On/Off wire. Connects to switched 12 volts.

BLACK

Connects to a good ground source.

LIGHT BLUE

Resets the timer to zero when switched to 12 volts.

DARK BLUE

Starts the timer when removed from 12 volts.

Channel 1 Output, switches ground, 2 amps max

Channel 2 Output, switches ground, 2 amps max

GRAY

YELLOW

MSD IGNITION

 • 1490 HENRY BRENNAN DR., EL PASO, TEXAS 79936 • (915) 857-5200 • FAX (915) 857-3344

SWITCHED

12 VOLTS

RED

12 VOLTS

12 VOLTS

RESET

SWITCH

TRANS

BRAKE OR

CLUTCH SWITCH

BLACK

LIGHT BLUE

DARK BLUE

GRAY

YELLOW

CHANNEL 2

OUTPUT

CHANNEL 1

OUTPUT

Figure 1 Basic Wiring of the Dual Delay Timer.

 

1 - Parts Bag 

Summary of Contents for 7563

Page 1: ... over 2 amps a relay will be required MSD offers a SPDT 30 Amp 12 Volt DC as PN 8961 or a DPDT 30 Amp 12 Volt DC as PN 8960 WIRING RED This is the On Off wire Connects to switched 12 volts BLACK Connects to a good ground source LIGHT BLUE Resets the timer to zero when switched to 12 volts DARK BLUE Starts the timer when removed from 12 volts Channel 1 Output switches ground 2 amps max Channel 2 Ou...

Page 2: ... you to the time setting which can be set from 0 01 9 99 seconds Also notice the mode indicators on the monitor Figure 2 Each of these LEDs will be illuminated while being programmed Also the LED will either be On when the Channel is activated or Off when the Channel is Off Once programmed the Light Blue wire must be momentarily connected to 12 volts This resets the Timer to zero When 12 volts are...

Page 3: ... GROUND 12V 12V 30 87a 87 85 86 TO GROUND 12V 12V Figure 4 Wiring High Current Applications Switching to Ground SWITCHED 12 VOLTS RED 12 VOLTS 12 VOLTS RESET SWITCH TRANS BRAKE OR CLUTCH SWITCH BLACK LIGHT BLUE DARK BLUE GRAY YELLOW 30 87a 87 85 86 TO GROUND TO GROUND 12V 30 87a 87 85 86 12V 12V 12V OR MSD RETARD UNIT CHANNEL 2 SWITCH TO GROUND CHANNEL 1 SWITCH TO GROUND TO ACTIVATE NITROUS TRANSM...

Page 4: ...se noted For more information call the MSD Customer Service Line 915 855 7123 MSD technicians are available from 7 00 a m to 6 00 p m Monday Friday mountain time TECH NOTES _________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________...

Reviews: