Page 1: ...USERGUIDE HARDWARE MTX xG JAVA IoT SMART SOLUTIONS FOR A CHANGING WORLD WeAreConnectivity www mtxm2m com ...

Page 2: ...1 Key features at a glance 15 The MTX 4G Java is a LTE bands mobile station with the characteristics shown in the table below 17 7 2 Operating modes 21 7 3 Power consumption 23 7 4 RF antenna interface description 25 7 5 SIM card 34 8 Precautions 35 9 Block Diagram 36 9 1 Models with Power Relay 220VAC 6A 36 9 2 Models with RJ11 connector and or analog audio 37 9 3 Models with 5 way terminal block...

Page 3: ...ating Temperatures 51 3 Storage Conditions 52 INTERFACE DESCRIPTION 53 1 Power Supply Connector 54 1 1 Models with Power Relay 220V 6A 5 way plug in 5 00mm pitch terminal block 54 1 2 Models with RJ11 connector 55 1 3 All other models 5 way plug in 5 00mm pitch terminal block 56 2 Micro USB Connector 57 3 DB9 Connector 8 wire RS232 58 4 DB15 HD Connector I O expansion port 60 4 1 Connector pinout ...

Page 4: ...PERATION 81 1 Switching on the modem New Automatic restart after shutdown feature 81 2 Power Modes 82 2 1 Ultra Low Power mode 82 2 2 Low Power mode 82 3 Status LEDs 83 EMBEDDED APPLICATIONS 85 1 MTX Tunnel Software Application 87 SAFETY AND PRODUCT CARE 89 1 Safety Instructions 89 2 General Precautions 90 3 SIM Card Precautions 91 4 Antenna Precautions 92 5 Radio Frequency RF Exposure and SAR 93 ...

Page 5: ...CONFORMITY ASSESSMENT 99 1 RED Declaration of Conformity 99 2 FCC Compliant 100 2 1 SAR information 100 DECLARACIÓN DE CONFORMIDAD 102 1 Declaración de conformidad RED 102 2 Conformidad FCC 103 2 1 Tasa de absorción específica SAR 103 REGULATORY AND TYPE APPROVAL INFORMATION 105 1 Directives and Standards 105 2 SAR Requirements Specific to Portable Mobiles 108 3 SELV Requirements 109 ROHS STATEMEN...

Page 6: ...based not be liable for any consequential incidental direct indirect punitive or other damages whatsoever including without limitation damages for loss of business profits business interruption loss of business information or data or other pecuniary loss arising out the use of or inability to use the documentation and or product even if Matrix Electronica S L U has been advised of the possibility ...

Page 7: ...ATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com REVISION INFORMATION REVISION DATE AUTHOR CHANGES 1 0 2016 01 AEM Initial release 1 1 2017 05 JS Approvals RED 1 2 2017 07 SJ Added LTE versions ...

Page 8: ...rially featured the unit can be used in industrial environments due to its extended operating temperature range It also features an automatic restart after shutdown function in case of power glitches or faulty conditions The MTX Java IoT are a self contained modems with its own SIM card holder USB 2 0 High Speed and RS232 485 interfaces among others which minimize the need for further hardware dev...

Page 9: ...ions Wireless xG 3G module 3G 2G 4G module 4G 3G 2G Wireless Modules BT Bluetooth 2 1 BLE Bluetooth low energy WC868 wavecard 25mW 868MHz WC868 LR wavecard 500mW 868MHz WC915 wavecard 25mW 915MHz WC915 LR wavecard 500mW 915MHz WMBUS WMBUS module TBD GPS GPS Glonass 165dBm ACCEL 3 axis accelerometer Note if using 2 modules the RS232 8 wire port DB9 will not be available anymore Options N no options...

Page 10: ...oT STANDARD VERSIONS CUSTOM VERSIONS by request only STD LC DB15 DB9 GPS RS232 8 wire X X RS232 4 wire X X RS485 X X X X USB X X X X ADC x2 x2 Optoisolated IO x4 x4 Counter input x3 x3 Analog Audio A 1 1 1 1 Li Po battery B 1 1 1 1 SuperCap S 1 1 1 1 Very Low Power V 1 1 1 1 Internal wireless module 1 1 1 1 Optional 1 option See incompatibility table ...

Page 11: ...32 4 wire DB15 RS485 A Analog audio B Li Po battery G GPS internal EHS8 S SuperCap V Very Low Power Wireless module GPS module 3G 3G 2G 4G 4G 3G 2G RS232 8 wire DB9 1 RS232 4 wire DB15 1 RS485 1 A Analog audio B Li Po battery G GPS internal EHS8 S SuperCap V Very Low Power Wireless module 1 1 1 GPS module 1 all serial ports not available at the same time Compatible Non compatible ...

Page 12: ...2 EDGE E2 power class for 8PSK GPRS class 12 mobile station class B PBCCH support CSD CSD data transmission up to 9 6 kbps V 110 non transparent SMS SMS text and PDU mode support SMS point to point MO and MT text and PDU mode General Features SIM application toolkit 3GPP release 99 _ Control and TCP IP stacks access via AT commands Internet services TCP UDP HTTP FTP SMTP POP3 Internal 1650mAh Li P...

Page 13: ...32 Real Time Clock with alarm functionality Multiplexer according 3GPP TS 27 010 RLS monitoring and informal network scan Java Features Oracle Java ME embedded 3 2 Compliant to CLDC 1 1 HI and IMP NG standards Capable of running multiple MIDIets in parallel with inter MIDIet communication Java standard APIs JSR75 FileConnection JSR177 CRYPTO JSR280 XML Accessible periphery for Java applications Me...

Page 14: ...56789 MTX MODEL NAME HR 0 00 FW 0 000 containsFCC ID XX 18xx IMEI 012345678912345 1 2 3 4 5 6 7 8 9 10 11 12 1 MTX logo 2 Part number ordering code 3 Product name model 4 Hardware and firmware versions 5 FCC ID 6 Year week of fabrication 7 Barcode code 128 IMEI 8 CE logo 9 RoHS symbol 10 WEEE symbol 11 Pb free symbol 12 PTCRB certification logo ...

Page 15: ...class Small MS Output power Class 4 33dBm 2dB for EGSM850 Class 4 33dBm 2dB for EGSM900 Class 1 30dBm 2dB for GSM1800 Class 1 30dBm 2dB for GSM1900 Class E2 27dBm 3dB for GSM 850 8 PSK Class E2 27dBm 3dB for GSM 900 8 PSK Class E2 27dBm 3dB 4dB for GSM 1800 8 PSK Class E2 27dBm 3 4dB for GSM 1900 8 PSK Class E2 26dBm 3 4dB for GSM 1800 8 PSK Class 3 24dBm 1 3dB for UMTS 2100 WCDMA FDD BdI Class 3 ...

Page 16: ...Class 12 Full PBCCH support Mobile Station Class B Coding Scheme 1 4 EGPRS Multislot Class 12 EDGE E2 power class for 8 PSK Downlink coding schemes CS 1 4 MCS 1 9 Uplink coding schemes CS 1 4 MCS 1 9 SRB loopback and test mode B 8 bit 11 bit RACH PBCCH support 1 phase 2 phase access procedures Link adaptation and IR NACC extended UL TBF Mobile Station Class B CSD V 110 RLP non transparent 9 6kbps ...

Page 17: ...mpatibility RIL for Pocket PC and Smartphone SIM Application Toolkit SAT Release 99 Firmware update Firmware update from host application over USB The MTX 4G Java is a LTE bands mobile station with the characteristics shown in the table below FEATURE IMPLEMENTATION General Frequency bands GSM GPRS EDGE Dual band 900 1800MHz LTE 800 Bd20 900 Bd8 1800 Bd3 2100 MHz Bd1 GSM class Small MS Output power...

Page 18: ...Class 12 Full PBCCH support Mobile Station Class B Coding Scheme 1 4 EGPRS Multislot Class 12 EDGE E2 power class for 8 PSK Downlink coding schemes CS 1 4 MCS 1 9 Uplink coding schemes CS 1 4 MCS 1 9 SRB loopback and test mode B 8 bit 11 bit RACH PBCCH support 1 phase 2 phase access procedures Link adaptation and IR NACC extended UL TBF Mobile Station Class B SMS Point to point MT and MO Cell broa...

Page 19: ...C and Smartphone SIM Application Toolkit SAT letter classes b c e with BIP Firmware update Generic update from host application over ASC0 or USB modem The following characteristics are common to MTX 3G Java and MTX 4G Java Interfaces depending on models USB Supports a USB 2 0 High Speed 480Mbit s device interface Full Speed 12Mbit s compliant RS232 8 wire Adjustable baud rates 1200bps to 921600bps...

Page 20: ...rface Supported chip cards UICC SIM USIM 3V 1 8V Antenna 50 Ohms GSM UMTS main antenna Power on off Reset Power on off Automatic switch on at power supply Switch off by AT command Switch off by hardware signal TURN_OFF Automatic switch off in case of high temperature or voltage conditions Software Reset Orderly shutdown and reset by AT command Hardware Reset Emergency reset by hardware signal TURN...

Page 21: ... network settings e g power control level uplink downlink data rates and GPRS configuration e g used multislot settings EGPRS DATA EGPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates and EGPRS configuration e g used multislot settings UMTS TALK UMTS DATA UMTS data transfer in progress Power consumption depends on network ...

Page 22: ...in TALK_GSM mode DTX off FR and no frequency hopping GPRS DATA GPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates and GPRS configuration e g used multislot settings EGPRS DATA EGPRS data transfer in progress Power consumption depends on network settings e g power control level uplink downlink data rates and EGPRS configur...

Page 23: ...S Data transfer GSM850 900 PCL 5 1Tx 4Rx ROPR 4 max reduction 67mA ROPR 0 no reduction GPRS Data transfer GSM850 900 PCL 5 2Tx 3Rx ROPR 4 max reduction 84 5mA ROPR 0 no reduction 115mA GPRS Data transfer GSM850 900 PCL 5 4Tx 1Rx ROPR 4 max reduction 90mA ROPR 0 no reduction 205mA EDGE Data transfer GSM850 900 PCL 5 1Tx 4Rx ROPR 4 max reduction 50mA ROPR 0 no reduction EDGE Data transfer GSM850 900...

Page 24: ...r GSM1800 1900 PCL 0 2Tx 3Rx ROPR 4 max reduction 62mA ROPR 0 no reduction 70mA EDGE Data transfer GSM1800 1900 PCL 0 4Tx 1Rx ROPR 4 max reduction 95mA ROPR 0 no reduction 115mA Average WCDMA supply current supply current IDLE UART activated but no communication DRX 6 USB disconnected 10mA USB active 16mA UMTS Data transfer Band I 23dBm 132mA UMTS Data transfer Band II 23dBm 150mA UMTS Data transf...

Page 25: ...NS TYP MAX ULP mode supply current TA 25ºC 25µA 35µA TA 85ºC 70µA 85µA 7 4 RF antenna interface description The table below briefly summarizes the RF Antenna interface GSM UMTS dBm PARAMETER CONDITIONS MIN TYP UMTS HSPA Connectivity Band I II V VI VIII Receiver Input Sensitivity ARP UMTS 800 850 Band VI V 104 7 106 7 110 UMTS 900 Band VIII 103 7 110 UMTS 1900 Band II 104 7 109 UMTS 2100 Band I 106...

Page 26: ... 1800 GSM 1900 30 RF Power ARP with 50Ohm Load ROPR 0 i e no reduction GPRS 1 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 1 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 2 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 2 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 3 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 3 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 4 TX GSM 850...

Page 27: ...M 900 33 GSM 1800 GSM 1900 30 EDGE 2 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 3 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 3 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 4 TX GSM 850 E GSM 900 31 GSM 1800 GSM 1900 28 EDGE 4 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 RF Power ARP with 50Ohm Load ROPR 2 GPRS 1 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 1 TX GSM 850 E GS...

Page 28: ...GSM 1900 26 GPRS 4 TX GSM 850 E GSM 900 29 GSM 1800 GSM 1900 26 EDGE 4 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 RF Power ARP with 50Ohm Load ROPR 3 GPRS 1 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 1 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 2 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 2 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 3 TX GSM 850 E GSM 900 33 GSM 1800 ...

Page 29: ...ROPR 4 i e maximum reduction GPRS 1 TX GSM 850 E GSM 900 33 GSM 1800 GSM 1900 30 EDGE 1 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 26 GPRS 2 TX GSM 850 E GSM 900 30 GSM 1800 GSM 1900 27 EDGE 2 TX GSM 850 E GSM 900 24 GSM 1800 GSM 1900 23 GPRS 3 TX GSM 850 E GSM 900 28 2 GSM 1800 GSM 1900 25 2 EDGE 3 TX GSM 850 E GSM 900 22 2 GSM 1800 GSM 1900 21 2 GPRS 4 TX GSM 850 E GSM 900 27 GSM 1800 GSM 1900 24...

Page 30: ...ivity ARP ch bandwidth 5MHz LTE 800 Band 20 97 LTE 900 Band 8 97 LTE 1800 Band 3 97 LTE 2100 Band 1 100 RF Power ARP with 50Ω Load Dual Antenna power supply 3 8V temperature 25 C LTE 800 Band 20 23 LTE 900 Band 8 23 LTE 1800 Band 3 23 LTE 2100 Band 1 23 GPRS Coding Schemes Class 12 CS1 to CS4 EGPRS Class 12 MCS1 to MCS9 GSM Class Small MS Static Receiver Input Sensitivity ARP GSM 900 102 109 GSM 1...

Page 31: ...M 1800 29 5 EDGE 1 TX GSM 900 27 GSM 1800 26 GPRS 2 TX GSM 900 32 5 GSM 1800 29 5 EDGE 2 TX GSM 900 27 GSM 1800 26 GPRS 3 TX GSM 900 32 5 GSM 1800 29 5 EDGE 3 TX GSM 900 27 GSM 1800 26 GPRS 4 TX GSM 900 32 5 GSM 1800 29 5 EDGE 4 TX GSM 900 27 GSM 1800 26 RF Power ARP with 50Ω Load ROPR 1 GPRS 1 TX GSM 900 32 5 GSM 1800 29 5 EDGE 1 TX GSM 900 27 GSM 1800 26 GPRS 2 TX GSM 900 32 5 GSM 1800 29 5 ...

Page 32: ...00 31 5 GSM 1800 28 5 EDGE 3 TX GSM 900 27 GSM 1800 26 GPRS 4 TX GSM 900 30 5 GSM 1800 27 5 EDGE 4 TX GSM 900 27 GSM 1800 26 RF Power ARP with 50Ω Load ROPR 2 GPRS 1 TX GSM 900 32 5 GSM 1800 29 5 EDGE 1 TX GSM 900 27 GSM 1800 26 GPRS 2 TX GSM 900 30 5 GSM 1800 27 5 EDGE 2 TX GSM 900 27 GSM 1800 26 GPRS 3 TX GSM 900 29 5 GSM 1800 26 5 EDGE 3 TX GSM 900 27 GSM 1800 26 ...

Page 33: ...25 5 EDGE 4 TX GSM 900 27 GSM 1800 26 RF Power ARP with 50Ω Load ROPR 3 GPRS 1 TX GSM 900 32 5 GSM 1800 29 5 EDGE 1 TX GSM 900 27 GSM 1800 26 GPRS 2 TX GSM 900 29 5 GSM 1800 26 5 EDGE 2 TX GSM 900 27 GSM 1800 26 GPRS 3 TX GSM 900 27 5 GSM 1800 24 5 EDGE 3 TX GSM 900 27 GSM 1800 26 GPRS 4 TX GSM 900 26 5 GSM 1800 23 5 EDGE 4 TX GSM 900 27 GSM 1800 26 ...

Page 34: ...1 TX GSM 900 27 GSM 1800 26 GPRS 2 TX GSM 900 29 5 GSM 1800 26 5 EDGE 2 TX GSM 900 24 GSM 1800 23 GPRS 3 TX GSM 900 27 5 GSM 1800 24 5 EDGE 3 TX GSM 900 22 GSM 1800 21 GPRS 4 TX GSM 900 26 5 GSM 1800 23 5 EDGE 4 TX GSM 900 21 GSM 1800 20 7 5 SIM card The MTX Java IoT supports an external SIM card through the integrated SIM holder Both 3V and 1 8V SIM technology is supported Older 5V SIM technology...

Page 35: ...mtxm2m com SALES info mtxm2m com mtxm2m com 8 Precautions MTX Java IoT as a standalone item is designed for indoor use only For outdoor use it must be integrated into a weatherproof enclosure Do not exceed the environmental and electrical limits as specified in Technical Data ...

Page 36: ...rocessor Cinterio Cellular M2M module 220 VAC 6A Relay Mini USB DB9 1 Internal Wireless module GPIO ADC DB15 I O expansion port 2 SIM Card Reader External Power Opto I O Analog IN I2C VREF Count input RS232 4 Wire RS232 8 Wire USB 2 0 High Speed ASC1 ASC0 GPS Antenna SMA F UMTS GSM Antenna FME M LED signaling Note 1 DB9 connector only available in STD and DB9 variants See section Introduction 2 Or...

Page 37: ...sor Cinterio Cellular M2M module Mini USB DB9 1 Internal Wireless module GPIO ADC DB15 I O expansion port 2 SIM Card Reader External Power Opto I O Analog IN I2C VREF Count input RS232 4 Wire RS232 8 Wire USB 2 0 High Speed ASC1 ASC0 GPS Antenna SMA F UMTS GSM Antenna FME M LED signaling RJ11 Audio Note 1 DB9 connector only available in STD and DB9 variants See section Introduction 2 Ordering Info...

Page 38: ...essor Cinterio Cellular M2M module Mini USB DB9 1 Internal Wireless module GPIO ADC DB15 I O expansion port 2 SIM Card Reader External Power Opto I O Analog IN I2C VREF Count input RS232 4 Wire USB 2 0 High Speed ASC1 ASC0 GPS Antenna SMA F UMTS GSM Antenna FME M LED signaling RS485 Note 1 DB9 connector only available in STD and DB9 variants See section Introduction 2 Ordering Information Note 2 D...

Page 39: ...ava IoT 2018 2 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 10 Hardware Revisions HARDWAREREVISION STARTING PRODUCTION DATE CHANGES 1 03 2016 02 Initial version ...

Page 40: ...tch terminal block The pictures below show the mechanical design of the unit along with the positions of the different connectors and mounting holes The device case is made of durable PC ABS plastic FME antenna 3G SMA antenna 4G Tri color LED indicator DB9 DB15 SIM card reader DIP switches and battery jumper Optional GPS 3G Micro USB 5 way plug in 5 00mm pitch terminal block Mounting holes ...

Page 41: ...S info mtxm2m com mtxm2m com 1 2 Models with RJ11 connector The pictures below show the mechanical design of the unit along with the positions of the different connectors and mounting holes The modem case is made of durable PC ABS plastic Mini USB Power supply Audio connector Mounting holes ...

Page 42: ...LECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 2 Dimensions mm 78 1 37 2 66 8 71 5 11 3 5 Packaging Box 15 units 37cm x 32cm x 4cm 1 211Kg Box 150 units contains 10 boxes of 15 units 38cm x 33cm x 48cm 20Kg ...

Page 43: ...CS 1 Electrical specifications 1 1 Power supply ABSOLUTE MAXIMUM RATINGS Symbol Parameter Conditions Min Max Unit VIN Supply voltage 0 3 65 V CHARACTERISTICS Symbol Parameter Conditions Min Typ Max Unit VIN Supply voltage 7 50 V IIN Supply current A η Efficiency VIN 24V IOUT 1 5A 87 fo Switching frequency 500 kHz See section Introduction 7 3 Power Consumption ...

Page 44: ...ivers 0 3 5 V Electrostatic discharge Human body model 2 kV CHARACTERISTICS Symbol Parameter Conditions Min Typ Max Unit VOH Driver high level output voltage RL 3kΩ to GND 5 5 4 V VOL Driver low level output voltage RL 3kΩ to GND 5 5 4 V ro Driver output resistance VIN 0V 300 10M Ω VIT Receiver positive going input threshold voltage 1 5 2 4 V VIT Receiver negative going input threshold voltage 0 6...

Page 45: ...model 16 kV Charged device model 1 kV CHARACTERISTICS Sym Parameter Conditions Min Typ Max Ut VOD Driver differential output voltage IO 0 2 3 V RL 54kΩ 5 5 4 V C OD Driver differential output capacitance VOD 0 4sin 4Eπt 0 5V 16 pF IOS Driver short circuit output current 250 mA VIT Receiver positive going input threshold voltage IO 8mA 0 065 0 01 V VIT Receiver negative going input threshold voltag...

Page 46: ...ymbol Parameter Conditions Min Typ Max Unit VIH High level input voltage 2 0 V VIL Low level input voltage 0 9 V 1 5 Optoisolated input output ABSOLUTE MAXIMUM RATINGS TCMD4000 OPTOCOUPLER Symbol Parameter Conditions Mn Max Unit Input VR Reverse voltage 6 V IF Forward current 60 mA IFSM Forward surge current 1 5 A Pdiss Power dissipation 100 mW Output VCEO Collector emitter voltage 35 V VECO Emitt...

Page 47: ...TCMD4000 OPTOCOUPLER Symbol Parameter Conditions Min Typ Max Unit Input VF Forward voltage IF 50mA 1 25 1 6 V Cj Junction capacitance VR 0V f 1MHz 50 pF Output VCEO Collector emitter voltage IC 100µA 35 V VECO Emitter collector voltage IE 100µA 7 V ICEO Collector dark current VCE 10V IF 0 100 nA Coupler VCEsat Collector emitter saturation voltage IF 50V IC 5mA 1 V fc Cut off frequency IF 10mA VCE ...

Page 48: ...tions in each case 1 6 Analog input output ABSOLUTE MAXIMUM RATINGS Symbol Parameter Conditions Min Max Unit VI Input voltag Voltage mode 12 5 85 V II Input current Current mode 6 42 mA Electrostatic discharge Human body model 2000 V Charge device model 500 V CHARACTERISTICS Symbol Parameter Conditions Min Max Unit Voa Analog output voltage range No resistive load 0 3 V RL 10kΩ 0 2 7 V Internal Re...

Page 49: ...LUTE MAXIMUM RATINGS Symbol Parameter Conditions Min Max Unit VI Input voltage 0 5 6 V Transient pulse 100 100 V CHARACTERISTICS Symbol Parameter Conditions Min Typ Max Unit VIH1 Input High 1 9 V VIL1 Input Low 0 9 V RWPU Weak pullup resistor 1000 1675 Ω VOL1 Output Low At 4mA load 0 4 V 1 8 Power relay CHARACTERISTICS Sym Parameter Conditions Typ Max Unit Contact rating DC 6 30 A V AC 6 250 A V R...

Page 50: ...cycles Mechanical endurance 107 cycles RI Insulation resistance At 500VDC 1000 MΩ 1 9 Latch relay CHARACTERISTICS Sym Parameter Conditions Typ Max Unit Contact rating DC 1 30 A V AC 0 5 125 A V RC Contact resistance At 10mA 30mVDC 100 mΩ ISW Switching current 2 A VSW Switching voltage DC 110 V AC 125 V Electrical endurance Resistive load at 70ºC 1s on 9s off 0 5A 125VAC 105 cycles Mechanical endur...

Page 51: ... operation allows normal mode speech calls or data transmissions for a limited time until the automatic thermal shutdown mode takes effect Within the extended temperature range outside the operating temperature range the specified electrical characteristics may be increased or decreased 2 Due to uncertainty in temperature measurement a tolerance of 3ºC on the stated shutdown thresholds may occur N...

Page 52: ...0068 2 1 Ab ETS 300 019 2 1 T1 2 IEC 60068 2 2 Db Relative humidity Low High Cond 10 90 at 30ºC 90 100 at 30ºC ETS 300 019 2 1 T1 2 IEC 60068 2 56 Cb ETS 300 019 2 1 T1 2 IEC 60068 2 30 Db Air pressure Low High 70 106 kPa IEC TR 60271 3 1 1K4 IEC TR 60271 3 1 1K4 Movement of air 1 0 m s IEC TR 60271 3 1 1K4 Water rain dripping icing and frosting Not allowed Radiation Solar Heat 1120 600 W m2 ETS 3...

Page 53: ...ir and contact Electrostatic Discharge ESD The modem family uses the following industry standard connectors USB mini connector DB9 female main RS232 port DB15 HD female I O expansion connector RJ11 6 way power supply connector 5 way plug in 5 00mm pitch terminal block power supply RS485 bus and relay SIM card reader FME male coaxial jack antenna connector SMA female coaxial jack GPS GNSS antenna c...

Page 54: ...s the D C power to the modem The supply voltage VCC required by the modem is in the range of 7 to 50VDC We recommend a 12VDC power supply The power supply has to be a single voltage source capable of providing a peak during an active transmission The uplink burst causes strong ripples drop on the power lines By default the MTX Java IoT will automatically switch on when power supply is applied betw...

Page 55: ...ltage source capable of providing a current peak during an active transmission The uplink burst causes strong ripples drop on the power lines MTX Java IoT devices are shipped to automatically switch on only with supply between PIN 1 and PIN 6 1 2 3 4 5 6 PIN SIGNAL DIRECTION LIMITS DESCRIPTION 1 VIN Input 6 5 40VDC Positive power input 2 TAMP Output Vmax VIN ULP negative wake up input see section ...

Page 56: ...ower supply The power supply has to be a single voltage source capable of providing a peak during an active transmission The uplink burst causes strong ripples drop on the power lines By default the MTX Java IoT will automatically switch on when power supply is applied between PIN 2 and PIN 1 1 2 3 4 5 PIN SIGNAL DIRECTION LIMITS DESCRIPTION 1 RxB I O RS485 B signal see section Interface Descripti...

Page 57: ...face is available as a command and data interface and for downloading firmware To properly connect the module s USB interface to the host a USB 2 0 compatible connector is required Furthermore the USB modem driver which is delivered with MTX Java IoT must be installed as described below The USB host is responsible for supplying power across the VUSB_IN line to the module s USB interface This is be...

Page 58: ... choice 1 2 3 4 5 6 7 8 9 The MTX Java IoT modem is designed to be used as a DCE data circuit terminating equipment Based on the conventions for DCE DTE connections it communicates with the customer application DTE data terminating equipment using the following signals Port TxD application sends data to TXD of MTX Java IoT Terminal Port RxD application receives data from RXD of MTX Java IoT Termin...

Page 59: ...D and fax services only available on the first logical channel The DTR0 signal will only be polled once per second from the internal firmware of MTX Java IoT The default configuration is 8 data bits no parity and 1 stop bit The setting can be changed using the AT command AT ICF and if required AT STPB Can be operated at fixed bit rates from 1200bps to 921600bps Autobauding supports bit rates from ...

Page 60: ...h signal are shown in figure below 1 5 6 15 10 11 PIN SIGNAL DIRECTION DESCRIPTION 1 NC Not connected 2 RD 1 Output RS232_1 signal Received data 3 TD 1 Input RS232_1 signal Transmitted data 4 IN 1 Input Opto isolated input 1 active low 5 OUT 3 Output Opto isolated output 3 open collector 6 NC Not connected 7 RTS 1 Input RS232_1 signal Request to send 8 CTS 1 Output RS232_1 signal Clear to send 9 I...

Page 61: ... S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 12 OUT 4 Output Opto isolated output 4 open collector 13 ADC 2 Input Analog to Digital converter input 2 14 GND Ground connection 15 ADC 1 Input Analog to Digital converter input 1 ...

Page 62: ...he following signals Port TxD application sends data to MTX 3G Java Terminal s TD Port RxD application receives data from MTX 3G Java Terminal s RD The RS232 interface is implemented as a serial asynchronous transmitter and receiver conforming to ITU T V 24 Interchange Circuits DCE It is configured for 8 data bits no parity and 1 stop bit and can be operated at fixed bit rates from 300bps to 460 8...

Page 63: ...e successive approximation conversion technique The maximum A D conversion rate is 5 samples per second To know how to read the analog inputs values please read the MTX Java IoT Family Software Manual 4 4 Optoisolated I O The STD and DB15 models have two optoisolated inputs and two optoisolated outputs located in the DB15 HD expansion port Please refer to section Interface Description 4 1 Connecto...

Page 64: ...t located in the DB15 HD expansion port Please refer to section Interface Description 4 1 Connector pinout to view the exact location of the signal I O The electrical equivalent circuits of the counter input is shown in following figure Internal coprocessor COUNT_IN VDD 100K 56VDC 100K Qp1 BC846B To know how to use this counter please read the MTX Java IoT Family Software Manual ...

Page 65: ...or selects which of those ports are connected to the GSM engine s UARTs ASC0 and ASC1 Users can select the ports configuring the decice s DIP switches Please read section Interface Description 7 DIP Switches to learn how to configure DIP switches in order to select the port of your choice It meets or exceeds the requirements of ANSI TIA EIA 485 A 1 2 3 4 5 PIN SIGNAL DIRECTION LIMITS DESCRIPTION 1...

Page 66: ...erial interfaces are enabled SW1 SW2 OFF RS232 DB9 enabled RS232 DB15 enabled RS485 disabled SW1 OFF SW2 ON default RS232 DB9 enabled RS232 DB15 disabled RS485 enabled SW1 ON SW2 OFF RS232 DB9 disabled RS232 DB15 enabled RS485 enabled SW1 ON SW2 ON Reserved for future uses 3 Periodic reset This switch enables the periodic reset OFF default disabled ON device will be restarted periodically Please r...

Page 67: ...5 way plug in 5 0mm pitch terminal block where the relay contacts Common Normally Close and Normally Open are available shared with the Power Supply The Power Relay contacts can handle 220VAC 6A 1 2 3 4 5 PIN SIGNAL DIRECTION LIMITS DESCRIPTION 1 GND Input Negative power ground 2 VIN Input 7 50VDC Positive power input 3 RL_NC 220VAC 6A relay Normally Close contact 4 RL_COM 220VAC 6A relay Common c...

Page 68: ...face provides one analog input for a microphone and one analog output for an earpiece The microphone input and the earpiece output are balanced For electret microphones a supply source is implemented The MTX Java IoT is pre configured to work with a range of handsets the audio interface is flexible and its performance can be configured using AT commands to match a particular handset or audio subsy...

Page 69: ...e 1 This is the default configuration optimized for the Votronic HH SI 30 3 V1 1 0 handset and used for type approving the MTX Terminals reference configuration Audio mode 1 has fixed parameters which cannot be modified To adjust the settings of the Votronic handset simply change to another audio mode Audio mode AT SNFS 1 not adjust 2 3 4 5 9 10 Name Default Handset Basic Handsfree Deadset User Ha...

Page 70: ...5mV 635mV Sidetone gain 15dB 96dB 17dB 20dB 12dB 96dB 1 In audio modes with noise reduction the microphone input signal for 0dBm0 shall be measured with a sine burst signal for a tone duration of 5 seconds and a pause of 2 sec The sine signal appears as noise and after aprox 12 sec is attenuated by the noise reduction 2 Signal for 5dBm0 due to attenuation of uplink filter at 1kHz ...

Page 71: ...ntenna connector allows radio frequency RF transmission signals between the modem and an external customer supplied antenna The modem is fitted with a 50Ω FME male coaxial jack RF signal GND The external antenna must be matched properly to achieve the best performance regarding radiated power DC power consumption modulation accuracy and harmonic suppression ...

Page 72: ...nel as shown below The card holder is a five wire interface according to GSM 11 11 It has a SIM card detector switch to detect whether or not the SIM card drawer is inserted Removing and inserting the SIM card during operation requires the software to be reinitialized Therefore after reinserting the SIM card it is necessary to restart the MTX 3G Java modem The full operation of the MTX Java IoT re...

Page 73: ...to the device for around 5 hours to fully charge the battery The battery level can be known using the AT command AT SBV The command result is given in mV When charging the previous value is increased by 200mV We do not guarantee fully working features for battery voltages below 3 6V We strongly recommend that you switch the modem off completely when this occurs The duration of discharge depends on...

Page 74: ...ar GPRS network The blue colored circle shows when the battery is being charged When it reaches 4 40V to be checked using the AT SBV command the battery is fully charged green colored circle In the above example charging time is 6 hours 30 minutes If the charger is disconnected the battery starts to discharge The duration of the battery is very dependent upon the applications used in the example a...

Page 75: ...so the more often you connect to GPRS the shorter the battery will last Keep GPRS connections short and infrequent where possible to extend battery life if you require longer periods of use without charging External power connected from 0 00 to 7 00 and only battery powered from 7 00 to 20 00 Java application running and storing the GPS position on the flash storage every five minutes and transmit...

Page 76: ...TC is supplied by a separate voltage regulator which is also active when the MTX Java IoT is in power down mode and the power supply VIN is available An alarm function is provided that allows the MTX Java IoT to wake up in Airplane mode without logging onto the GSM UMTS network The MTX Java IoT modems also accommodate an independent super cap inside to maintain the date and time of the RTC when th...

Page 77: ...l satellites in view thus providing accurate satellite positioning data The GPS receiver supports the NMEA protocol via serial port RS232 RS485 and USB interface It is able to recognize input messages from any of these protocols e g GGA RMC GSA GSV and respond to them accordingly Input messages can be arbitrarily mixed The NMEA protocol is an industry standard protocol developed for marine electro...

Page 78: ... CONDITIONS MIN TYP MAX UNIT Frequency 1575 1575 42 1585 MHz Tracking Sensitivity Open sky Active antenna or LNA Passive antenna 167 162 dBm Acquisition Sensitivity Open sky Active antenna or LNA Passive antenna 150 145 dBm Time to First Fix TTFF Hot average at 140dBm 2 S Warm average at 140dBm 35 S Cold average at 140dBm 46 S ...

Page 79: ...and Bluetooth RS232 with MTX Tunnel software It includes an antenna with a 300 meters reach Temperature range 40ºC to 85ºC 14 2 Bluetooth Low Energy 4 0 This option allows to make a Bluetooth IP connection with MTX Tunnel with 128 bit encryption sensors or BLE peripheral in a range up to 50 meters The antenna is built in in the pcb itself with a sensitivity up to 92 dbm Temperature range 40ºC to 8...

Page 80: ...rt mtxm2m com SALES info mtxm2m com mtxm2m com 15 Firmware Updates It is possible and sometimes necessary to update the MTX Java IoT firmware Updates must be carried out by an approved technician Please contact gsmsupport matrix es for details regarding Service Programming ...

Page 81: ...iption 1 Power Supply Connector The modem will be fully operational after 4 to 9 seconds Logging onto a network may take longer than this and is out of the modem s control The Automatic Restart after Shutdown feature is enabled as part of the default factory settings and can t be disabled This means that if when the modem has to be switched off due to a critical power supply the modem will restart...

Page 82: ...t allowing the modem to power up again By the RTC alarm please read the MTX Java IoT Family Software Manual to configure the RTC alarms It is possible to know if the modem has been woken up by inputs or the RTC alarm by reading the status latches Devices ordered with Ultra Low Power Controller option U also can enter in Low Power Mode which is explained in section Operation 2 2 Low Power Mode To l...

Page 83: ...ogress Permanently ON 10ms ON 990ms OFF flash ms ON 990 ms OFF GSM PS data transfer UMTS data transfer Permanently ON 10ms ON 1990ms OFF flash ms ON 1990 ms OFF ME registered to a network No call no data transfer Permanently ON 10ms ON 1990ms OFF flash ms ON 3990 ms OFF Limited Network Service e g no SIM no PIN or during network search 500ms ON 500ms OFF 10ms ON 990ms OFF flash ms ON 990 ms OFF Th...

Page 84: ...IoT i e for entering AT commands receiving URCs or sending and receiving short messages It cannot be used as a data interface for UMTS or GPRS Please note that URCs are normally indicated only on this interface no matter whether the Modem interface or the Application interface was used to send the AT commands to activate their presentation This URC management scheme is the default configuration re...

Page 85: ...e used by the customer This solution saves the external intelligence with all the associate costs and also saves space and power consumption Old solution The customer application was distributed across 2 µC external µC and internal µC on the module GSM Module Customer SW µC ROM RAM Customes Application New solution The customer application exists only on the module Customes Application GSM Module ...

Page 86: ...ins I2C Interface SPI interface DAC ADC Serial interfaces API ASC0 ASC1 USB can be used to connect external devices Memory space for Java programs Flash File System around 8 MB RAM around 6MB Just in Time Compiler execution optimization Over the air update Application SW OTAP Firmware FOTA OMA compliant Ask gsmsupport matrix es for application notes and a free SDK Software Development Kit we will ...

Page 87: ... EHS6 module which is designed for communicating with remote devices that have RS232 ports Frequently remote meters network switches routers or other devices need to connect to the network but they only have an RS232 port and the only possible way to reach them is using the GSM GPRS Network MTX Tunnel is ready to go solution for such cases INTERNET ADSL 2G 3G 4G RS232 485 device DATA Digital input...

Page 88: ... calls authorized or blocked phone numbers Change on an input digital level An analog input is out of the selected level window MIN MAX Serial data present on RS232 RS485 port Scheduled date hour timing WebServer Telnet SMS Alarms and Output control IPs dynamic resolution DynDNS Private DNS SMS SSL Security Firewall IP User API Telemetry GPIOs and GPS Serial RS232 485 HTTP Tunnel Serial RS232 485 ...

Page 89: ...odem must not be used in hospitals airports or planes Never use the modem at a gas station refueling point blasting area or in any other environment where explosives may be present Operating the modem close to other electronic devices such as antennas television sets and radios may cause electromagnetic interference This product is intended to be used with the antenna or other radiating element at...

Page 90: ... may invalidate the warranty The MTX Java IoT modem must not be installed nor located in areas where the surface temperature of the plastic case could exceed 85 C In order to provide strain relief and to avoid transmitting excessive vibration to the modem during installation all cables connected to the MTX Java IoT modem must be secured or clamped immediately adjacent to the modem s connectors To ...

Page 91: ...rostatic discharges When the SIM card hatch is opened the SIM card connectors lie exposed under the SIM card holder Caution Do not touch these connectors If you do you may release an electrical discharge that could damage the modem or the SIM card When designing your application the SIM card s accessibility should be taken into account We always recommend that you have the SIM card protected by a ...

Page 92: ...bile station the antenna of the modem emits radio frequency energy To avoid EMI electromagnetic interference you must determine whether the application itself or equipment in the application s proximity needs further protection against radio emission and the disturbances it might cause Protection is secured either by shielding the surrounding electronics or by moving the antenna away from the elec...

Page 93: ...f all persons regardless of age and health and to account for any variations in measurements Specific Absorption Rate SAR is the unit of measurement for the amount of radio frequency energy absorbed by the body when using a transceiver The SAR value is determined at the highest certified power level in laboratory conditions but the actual SAR level of the transceiver while operating can be well be...

Page 94: ...tion of cardiac pacemakers hearing aids and certain other implanted equipment If a minimum distance of 15 cm 6 inches is maintained between the MTX Java IoT modem radiating antenna and a pacemaker the risk of interference is limited If the user s application is likely to be situated in the vicinity of personnel a suitable warning should be contained in the equipment manual to this effect ...

Page 95: ...adation in signal strength can be the result of disturbance from another source for example an electronic device in the immediate vicinity More information about possible communication disturbances can be found in section Operation 3 5 Possible communications disturbances When an application is completed you can verify the signal strength by issuing the AT command AT CSQ Tip Before installing the ...

Page 96: ...wered from a battery or a high current supply connect a fast 1 25A fuse in line with the positive supply This protects the power cabling and modem 2 2 Securing the modem Before securing the modem take into account the amount of additional space required for the mating connectors and cables that will be used in the application Where access is restricted it may be easier to connect all the cables to...

Page 97: ...tenna suitable for your application 3 2 Antenna type Make sure that you choose the right type of antenna for the modem Consider the following requirements The antenna must be designed for one of the frequency bands in use please ask your network provider for more information UMTS 800 850 900 1900 2100 MHz GSM 850 900 1800 1900 MHz The impedance of the antenna and antenna cable must be 50Ω The ante...

Page 98: ...ible communication disturbances include the following Noise can be caused by electronic devices and radio transmitters Path loss occurs as the strength of the received signal steadily decreases in proportion to the distance from the transmitter Shadowing is a form of environmental attenuation of radio signals caused by hills buildings trees or even vehicles This can be a particular problem inside ...

Page 99: ...960 N2900 A300 object of the declaration described above is in conformity with the relevant Union harmonization Legislation RED Directive 2014 53 EU and R TTE Directive 99 5 EC The following harmonized standards and or other normative documents were applied and are labeled with the CE conformity mark EMC art 3 1 b EN 301 489 1 V2 2 0 EN 301 489 52 V1 1 0 EN 301 489 3 V2 1 1 RADIO SPECTRUM art 3 2 ...

Page 100: ... Wireless Modules models EHS6 is marketed without a defined antenna The Maximum Antenna Gain when using indoor antennas depends on the distance from the antenna to any nearby persons when in normal operation It should not exceed the values shown on the table below According to the limit in 47 CFR 1 1310 we get the value of the maximum antenna gain as follows The maximum measured power output in th...

Page 101: ...ATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com Solving for G the maximum antenna gain is BAND DISTANCE MAX GAIN dBi 850MHz 20cm 1 7669 850MHz 50cm 9 7257 1900MHz 20cm 7 1227 1900MHz 50cm 15 0815 ...

Page 102: ...94 que contienen un módulo celular EHS6 tipo L30960 N2950 A100 al cual se refiere esta declaración están conformes con Directiva RED 2014 53 EU y R TTE 99 5 EC Estos estándares armonizados permiten etiquetar al producto con el marcado CE EMC art 3 1 b EN 301 489 1 V2 2 0 EN 301 489 52 V1 1 0 EN 301 489 3 V2 1 1 RADIO SPECTRUM art 3 2 EN 301 511 V12 5 1 EN 301 908 1 V11 1 1 EN 301 908 2 V11 1 1 EN ...

Page 103: ...nd GSM GPRS Modem 2 1 Tasa de absorción específica SAR El modulo EHS6 es comercializado sin una antena definida La ganancia máxima de antena usando antenas de interior depende de la distancia de esta a las personas cercanas y en condiciones normales no debe sobrepasar los límites mostrados en la tabla siguiente La máxima potencia de salida medida en la banda de 850MHz es 1866 38 mW 32 71 dBm ver e...

Page 104: ...IX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com Despejando G la máxima ganancia de antena es BANDA DISTANCIA GANANCIA MÁX dBi 850MHz 20cm 17669 850MHz 50cm 97257 1900MHz 20cm 71227 1900MHz 50cm 150815 ...

Page 105: ...rmity mark ECE R 10 Economic Commission for Europe ECE Regulation No 10 Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility 2002 95 EC RoHS 1 2011 65 EC RoHS 2 Directive of the European Parliament and of the Council of 27 January 2003 and revised on 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic...

Page 106: ...illary equipment of digital cellular radio telecommunications systems GSM and DCS ETSI EN 301 489 24 V1 5 1 Electromagnetic Compatibility and Radio spectrum Matters ERM Electromagnetic Compatibility EMC standard for radio equipment and services Part 24 Specific conditions for IMT 2000 CDMA Direct Spread UTRA for Mobile and portable UE radio and ancillary equipment EN 301 908 01 V5 2 1 Electromagne...

Page 107: ...f Pollution Caused by Electronic Information Products 2006 06 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the product is operated within the operating limits descr...

Page 108: ... EN 59005 ANSI C95 1 Considerations for evaluation of human exposure to Electromagnetic Fields EMFs from Mobile Telecommunication Equipment MTE in the frequency range 30MHz 6GHz Products intended for sale in European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields 300MHz 3GHz Please not...

Page 109: ... MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 3 SELV Requirements ThepowersupplyconnectedtotheMTX Java IoTmodemshallbeincompliancewiththeSELVrequirements defined in EN 60950 1 ...

Page 110: ...m com ROHS STATEMENT The MTX Java IoT modem is compliant with the 2002 95 EC RoHS 1 and 2011 65 EC RoHS 2 directives of the European Parliament and of the Council of 27 January 2003 and revised on 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS ...

Page 111: ...r to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed informat...

Page 112: ...nce Point ASC0 ASC1 Asynchronous Controller Abbreviations used for first and second serial interface of EHS6 B Thermistor Constant VER Bit Error Rate BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene European Conformity CHAP Challenge Handshake Authentication Protocol CPU Central Processing Unit CS Coding Scheme CSD Circuit Switched Data CTS Clear to Send DAC Di...

Page 113: ...al Signal Processor DSR Data Set Ready DTE Data Terminal Equipment typically a computer terminal printer or for example a GSM application DTR Data Terminal Ready DTX Discontinuous Transmission EDGE Enhanced Data rates for GSM Evolution EFR Enhanced Full Rate EGSM Enhanced GSM EIRP Equivalent Isotropic Radiated Power EMC Electromagnetic Compatibility ERP Effective Radiated Power ESD Electrostatic D...

Page 114: ...Service GSM Global Standard for Mobile Communications HiZ High Impedance HR Half Rate HSDPA High Speed Downlink Packet Access I O Input Output IC Integrated Circuit IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Li Ion Li Lithium Ion Li battery Rechargeable Lithium Ion o...

Page 115: ...vel MT Mobile Terminated nc Not connected NTC Negative Temperature Coefficient OEM Original Equipment Manufacturer PA Power Amplifier PAP Password Authentication Protocol PBCCH Packet Switched Broadcast Control Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCN Personal Communications Network also referred to as DCS 1800 PCS Personal Communication System also r...

Page 116: ... R TTE Radio and Telecommunication Terminal Equipment RAM Random Access Memory RF Radio Frequency RLS Radio Link Stability RMS Root Mean Square value RoHS Restriction of the use of certain hazardous substances in electrical and electronic equipment ROM Read only Memory RTC Real Time Clock RTS Request to Send Rx Receive Direction SAR Specific Absorption Rate SAW Surface Acoustic Wave SELV Safety Ex...

Page 117: ...ltiple Access TE Terminal Equipment also referred to as DTE TLS Transport Layer Security TPC Transmit Power Control TS Technical Specification Tx Transmit Direction UART Universal asynchronous receiver transmitter UICC USIM Integrated Circuit Card UL Upload UMTS Universal Mobile Telecommunications System URC Unsolicited Result Code USB Universal Serial Bus USIM UMTS Subscriber Identification Modul...

Page 118: ... manual can be downloaded from the MTX Java IoT web page at www mtxm2m com AT COMMAND DESCRIPTION Switch from data mode or PPP online mode to command mode A Repeat Previous Command Line AT C Set Data Carrier Detect DCD Line Mode AT D Set Data Terminal Ready DTR Line Mode AT F Reset AT Command Settings to Factory Default Values AT S Set Data Set Ready DSR Line Mode AT V Display current configuratio...

Page 119: ...r PDP context activation AT CGCMOD PDP Context Modify AT CGDATA Enter data state AT CGDCONT Define PDP Context AT CGEQMIN Rel 99 Quality of Service Profile Minimum acceptable AT CGEQREQ Rel 99 Quality of Service Profile Requested AT CGEREP GPRS event reporting AT CGMI Request manufacturer identification AT CGMM Request model identification AT CGMR Request revision identification of software status...

Page 120: ...y lock AT CLIP Calling Line Identification Presentation AT CLIR Calling Line Identification Restriction AT CMEE Error Message Format AT CMGC Send SMS Command AT CMGD Delete short message AT CMGF Select SMS message format AT CMGL List SMS messages from preferred store AT CMGR Read SMS messages AT CMGS Send SMS AT CMGW Write Short Messages to Memory AT CMMS More Messages to Send AT CMSS Send short m...

Page 121: ...tries AT CPBR Read from Phonebook AT CPBS Select phonebook memory storage AT CPBW Write into Phonebook AT CPIN PIN Authentication AT CPIN2 PIN2 Authentication AT CPLS Select Preferred Operator List AT CPMS Preferred SMS message storage AT CPOL Preferred Operator List AT CPUC Price per unit and currency table AT CPWD Change Password AT CR Service reporting control AT CRC Incoming Call Indication Fo...

Page 122: ...t Message Service AT CSQ Signal quality AT CSSN Supplementary service notifications AT CSTA Select type of address AT CSVM Set voice mail number AT CTZR Time Zone Reporting AT CTZU Automatic Time Zone Update AT CUSD Unstructured Supplementary Service Data AT GSN Request International Mobile Equipment Identity IMEI AT IPR Bit Rate AT STKCC USAT Call Control Notification AT STKCNF USAT Proactive Ses...

Page 123: ...ring AT SFDL Firmware Download AT SFSA Flash File System Access AT SGAUTH Set Type of Authentication for PDP IP Connections AT SGIO Get IO state of a specified pin or port AT SHUP Hang up call s indicating a specific 3GPP TS 24 008 release cause AT SICI Internet Connection Information AT SICS Internet Connection Setup Profile AT SIND Extended Indicator Control AT SIPS Internet Profile Storage AT S...

Page 124: ...Midlet Security AT SJNET Set Dialup Network Access Parameters AT SJOTAP Over The Air Application Provisioning AT SJRA Run Java Application AT SLED LED Feature AT SMGL List Short Messages from preferred store without setting status to REC READ AT SMGR Read short message without setting status to REC READ AT SMONI Monitoring Serving Cell AT SMONP Monitoring Neighbour Cells AT SMSO Switch Off EHS6 AT...

Page 125: ...al Protocol Interface AT SSTA Remote SAT Interface Activation AT SWDAC PWM Signal Configuration for DAC AT SXCALLSTAT Set Reporting Call Status AT SXEONS Display Eons names AT SXRAT Selection of Radio Access Technology ATA Connect to Incoming Call ATA Manual acceptance of a network request for PDP context activation ATD Mobile originated call to specified number ATD 99 Request Packet Domain Servic...

Page 126: ...ine mode ATQ Result Code Presentation Mode ATS0 Set number of rings before automatically answering a call ATS10 Set disconnect delay after indicating the absence of data carrier ATS3 Command Line Termination ATS4 Response Formatting ATS5 Command Line Editing ATS6 Set pause before blind dialing ATS7 Set number of seconds to wait for connection completion ATS8 Comma Dial Pause Time ATV Result code f...

Page 127: ...S The MTX Java IoT has a wide range of available accessories including Power supplies All type of antennas indoor outdoor high gain etc Cables and DIN adapters The MTX Java IoT is shipped without any accessories Please visit the following web sites to see the full range of accessories mtxm2m com en modem router gateway accesories ...

Page 128: ...4 Sant Cugat del Vallés Barcelona Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX DURANGO Matrix Electrónica S L Pol Aliendalde 11 oficina 2G 48200 Durango Vizcaya Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX VALENCIA Matrix Electrónica S L Valencia Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX SEVILLA Matrix Electrónica S L Sevilla Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX LISBOA L...