background image

RESET

SET
ENT

BC 445

BATCH

TOTAL

BATCH CT





SET
ENT

RESET

BC 2046

TOTAL

BATCH COUNT

R





R

BC 1046D





www.multispanindia.com

Page - 1

BC-1046D,2046,445

Proximity PNP/NPN (Selectable) & Micro Switch

Nonvolatile

 Power Supply

 Protection Level

    Operating

    Relative

 (As per request)

 Temperature

   Humidity

230V AC, 50 Hz, Approx 4VA 

100 To 250V AC, 50/60 Hz, Approx 4VA 

IP-65(Front side) AS per IS/IEC 60529:2001

0°C To 55°C

Up to 95% RH Non Condensing

Model

Display

Size(HXWXD)
Panel Cutout

Output

Sensor

Memory

BC-1046D

96 X 96 X 45 mm

92 X 92  mm

68 X 68 mm

44 X 44 mm

72 X 72 X 60 mm

48 X 48 X 95 mm

UPPER:- 6 Digit 7 seg 0.56”,
red LED Display

UPPER:- 6 Digit 7 seg 0.4”,
red LED Display

UPPER:- 5 Digit 7 seg 0.3”,
red LED Display

LOWER:- 4 Digit 7 seg 0.4”,
green LED Display

LOWER:- 4 Digit 7 seg 0.4”,
green LED Display

LOWER:- 4 Digit 7 seg 0.3”,
green LED Display

BC-2046

BC-445

 1 Relay, 1C/O,230V AC,5A & Buzzer

 1 Relay, 2C/O,230V AC,5A & Buzzer

Technical Specification  

Connection Diagram  

OPERATING MANUAL 

PID TEMPERATURE CONTROLLER                           

UTC-121P,221P & 421P

Technical Specification  

Connection Diagram  

OPERATING MANUAL 
BATCH COUNTER                       

BC-1046D,2046,445

7

8

9

10

5

6

L

N

1

2

3

4

 

230V AC

 

 

50Hz, 4VA

RST

NC

C

NO

RELAY

MICRO SWITCH:-  M/S Connection 7 & 9

+12V

I/P

I/P

NPN

PNP GND

!

12

11

BUZZER

-

+

15

18

16

19

17

20

BUZZER

-

+

 

230V AC

 

 

50Hz,4VA

NC

I/P

NPN

+12V

I/P

PNP

GND

NO

C

L

N

1

2

3

4

5

6

7

8

9

10

11

12

13

14

!

RESET

MICRO SWITCH:- 

                        M/S Connection 9 & 11

!

100  
250V AC
    

~

 

50/60 HZ
4VA

1

2

3

4

5

L

N

7

6

8

9

10

11

12

RELAY

BUZZER

I/P2

NC

C

NO

M/S

I/P1

+12V

GND

+

-

Note:

1. For NPN Proxi Short pin 3 & 4

2. For PNP Proxi Short pin 6 & 5

3. For Microswitch Short pin 6 & 5

 Proxi Connction to 4,6,5

 Proxi Connction to 3,4,5

 Micro switch Connection to 3 & 4

Summary of Contents for BC-1046D

Page 1: ...ED Display LOWER 4 Digit 7 seg 0 4 green LED Display LOWER 4 Digit 7 seg 0 3 green LED Display BC 2046 BC 445 1 Relay 1C O 230V AC 5A Buzzer 1 Relay 2C O 230V AC 5A Buzzer Technical Specification Connection Diagram OPERATING MANUAL PID TEMPERATURE CONTROLLER UTC 121P 221P 421P Technical Specification Connection Diagram OPERATING MANUAL BATCH COUNTER BC 1046D 2046 445 7 8 9 10 5 6 L N 1 2 3 4 230V ...

Page 2: ...ress Key Press Key For Program Press Key Press Key Total Batch Count Batch Count BC 1046D 2046 445 Key Operation 1 Press Key to go next parameter 2 Release the Key to save the set point 3 Press Key for manual reset of total count Press Key To save exit Press Key To save exit ...

Page 3: ...t Set Count 2 Batch setting Always set the value of set 1 less then set 2 When it reaches to set count 1 Relay Buzzer will be ON when it reaches to set count 2 Relay Buzzer will be OFF Batch Count will be zero Note Press key and power on the instrument Display will show parameters SLOW MEDIUM FAST Set Speed Selection by Pressing key SLOW MAX RPM 500 MEDIUM MAX RPM 5000 FAST MAX RPM 15000 Press key...

Page 4: ...nter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains switch must be installed between power source and supply terminal to facilitate power ON or OFF function However this mains switch or circuit breaker must be installed at convenient place normally accessible to the operator 4 Use and store the ...

Reviews: