UTC-3203
www.multispanindia.com
Page - 2
All safety related codifications, symbols and instructions that appear in this operating manual
or on the equipment must be strictly followed to ensure the safety of the operating personnel as
well as the instrument.
If all the equipment is not handled in a manner specified by the manufacturer, it might impair the
protection provided by the equipment .
Product improvement and upgrade is a constant procedure. So for more updated operating information and support,
Please contact our helpline : +91-9978991474/76/82 or Email at marketing@multispanindia.com Ver: 06-2017
=>
Read complete instructions prior to installation and operation of the unit.
WARNING
: Risk of electric shock.
3) Cable used for connection to power source, must have a cross section of 1mm or greater. These wires
should have insulations capacity made of at least 1.5kV.
2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of
equal size shall be made with shortest connection.
4) When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring
for the RTD type, use a wiring material with a small lead resistance (5
Ω
max per line)and no resistance
differentials among three wires should be present.
1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the
wiring arrangement. Do not touch the terminals while power is being supplied.
5) A better anti-noise effect can be expected by using standard power supply cable for
the instrument.
1) This equipment, being built-in-type, normally becomes a part of main control panel and in such case the
terminals do not remain accessible to the end user after installation and internal wiring.
2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product
or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
3) Circuit breaker or mains switch must be installed between power source and supply terminal to
facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be
installed at convenient place normally accessible to the operator.
4) Use and store the instrument within the specified ambient temperature and humidity ranges as
mentioned in this manual.
Warning Guidelines
Installation Guidelines
Mechanical Installation
Maintenance
Safety Precautions
1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source,
caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals.
1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any
other cleaning agent.
3) Fusible resistor must not be replaced by operator.
2
A
B
MODEL
A
96mm
48mm
44mm
92mm
6mm
85mm
B
C
D
E
F
DIMENSIONS
120mm - 4.72 inches
60mm - 2.36 inches
F
E
C
D
°C
ENT
UTC 3203
°C
R1
R2
R3
1 2 3 4
1 2 3 4
www.multispanindia.com
Page - 1
UTC-3203
Connection Diagram
OPERATING MANUAL
UNIVERSAL TEMPERATURE CONTROLLER
UTC-3203
Note:
1)
If sensor connection is reversed, display will show “
SRE
” message.
2) If sensor is not connected, display will show
Open
message.
3) Every time the instrument is turned ON, following pattern will be displayed
POWER ON
j
0 1 2 3
0 1 2 3
I N P t
8 8 88
8
8
8
8
All digit segment will be turned ON for 3 sec
Previous or default sensor input will be displayed for 2 sec
Process Value
Set Value
J: 0 to 600°C / K: 0 to 1200°C /
PT-100: -99 to 400ºC, PT.1: -99.0 to 400.0°C
TP/PID/ ON-OFF (selectable)
Output
Power Supply
Operating
Temperature
Relative
Humidity
100 to 250V AC,50/60 Hz, Approx 4VA
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size (mm)
Panel Cutout
Input
Temperature
Range
Control Action
96 (H) X 48 (W) X 85 (D) mm
92 X 44 mm
UTC-3203
J, K, PT-100
3Relay, 1C/O Contact, 5A,230V AC,
Technical Specification
Protection
Level
(As per request)
IS/IEC 60529 : 2001
IP-65 (Front side) As per
UPPER:- 4 Digit 7 seg 0.39”, red LED Display
LOWER:- 4 Digit 7 seg 0.28”, green LED Display
°C
ENT
UTC 3203
°C
R1
R2
R3
1 2 3 4
1 2 3 4
NO
C
R3
NC
!
L
N
RTD
100
250V AC
~
50/60 Hz,4VA
NO
NO
C
C
R1
R2
NC
NC
T/C
-
-
-