background image

 

 

 

Summary of Contents for UM018

Page 1: ......

Page 2: ... Device 8 z Preview 11 z App Icon Definitions 12 z Change Password 13 z Setup Date Time 14 z Delete a Microscope 15 Install the microscope to Stand 16 How to get focus 19 Install Software on PC 20 Start Microscope 21 Software functions 22 z Capture Photo 22 z Capture Video 22 z Timer 23 Calibration and Measurement 24 z Calibration 24 z Measurement 28 z Change Calibration 28 z Draw and text 32 Soft...

Page 3: ...er currency plants insects skin fabrics rocks and minerals and so much more We recommend reading this manual first to get the best out of this unit 1 Precaution Before using the Wifi Digital Microscope please ensure that you read and understand the safety precautions described below Always ensure that the Wifi Digital Microscope is operated correctly z The Microscope is not waterproof so keep it d...

Page 4: ...e Powerful light may hurt the light sensitive electronics z Avoid touching the lens z The white LEDs which illuminate the Microscope target field are very bright Do not stare directly into these LEDs as it may damage your eyes z The clear plastic distance shell sometimes picks up dirt or toxic material from a microscopically observed surface Be careful that this doesn t get in contact with the hum...

Page 5: ...4 2 Preparation Standard accessories Microscope Stand AC adaptor USB cable QSG AC adaptor Calibration Ruler Cleaning Fabric ...

Page 6: ... Part Meaning 1 Off Wifi USB 7 Wheel Fixing the movement 2 LED Dimmer 8 Wheel for up down 3 Charging Indicator 9 Wheel fixing on the pole 4 USB PC and Charge 10 Wheel fixing on the stage 5 LED 11 Wheel fixing the microscope 6 Focus Wheel ...

Page 7: ... Mega Pixels true resolution Still capture resolution 1280x720 720P 640x480 VGA Video capture resolution 1280x720 720P 640x480 VGA Magnification Ratio 10x 200x Focus Range Manual focus from 0mm to 150mm Video format H 264 Photo format JPEG Light source 6 LED adjustable by control wheel Power source Rechargeable Li ion battery Working time 90mins Charging time 100mins Charging power 5V DC iOS Andro...

Page 8: ...Deutsch Spanish Russian Italian French Portuguese Dutch Polish Japanese Korean PC Software OS Supported Windows XP Vista Win7 Win8 Size Microscope 154mm L x 44mm R Professional Stand 165mm L x118mm W x12mm H 3 Use the Wifi Microscope on iOS Android Device 1 Download App iOS Search and install WifiCapture from App Store Android Search WifiCapture from play google com store download and install it O...

Page 9: ...wer on the microscope by sliding the Par1 1 to WIFI position 2 Turn on the Wifi of your iOS Android Device search the Wifi Digital Microscope from the Wifi Device list The Wifi Microscope name is WIFICAMxxxx xxxx stand for four digit random number as follows The password to connect the device is 123456789 ...

Page 10: ...9 3 Start the installed App as follows 4 Add Camera Click Add new camera then click Search ...

Page 11: ...searched Wifi Camera will be shown on the Search result list Click the Device name for example WIFICAM OBJ 002864 STBZD 5 User name is admin default password is 123456 and then the online Wifi Camera is listed ...

Page 12: ...11 3 Preview Click the listed Wifi Camera it starts preview as follows The preview can be vertical or horizontal ...

Page 13: ... App Interface Icon Definition IQ Still Image Capture Flip Left Right Video Capture Flip Up Down Change resolution 720P VGA QCGA Brightness Screen Rotation Vertical Horizontal Contrast Exit Back to Default ...

Page 14: ...3 Main Interface Captured Still Image Captured Video Version info 5 Change Password From the camera list click choose User and then input new password Click Done on the right corner to confirm the setup ...

Page 15: ...14 6 Setup Date Time From the camera list click choose Time and then click use the phone time calibrate device s clock ...

Page 16: ...Camera You can delete an existing Wifi Camera Press Edit at the right corner 1 For iOS by sliding left or right a target Camera then confirm to delete it 2 For Android tick to select a target camera and then choose Delete ...

Page 17: ...roscope to the Stand 1 Take the microscope out from gift box gently put the carriage stage on a flat surface 2 Follow the below steps Put the metal pole through Wheel 10 Put the metal pole into the female part of the stage ...

Page 18: ...17 Rotate Wheel 10 to fix the pole on the stage Put the microscope into the ring of the stand ...

Page 19: ...18 Rotate Wheel 11 clockwise to fix the microscope on the ring 1 Adjust the upper part of the stand to get a proper height 2 Rotate Wheel 9 clockwise to fix the upper part ...

Page 20: ...19 4 How to get focus Rotate Wheel 8 to get a rough focus Rotate Wheel 6 to get a fine focus Rotate Wheel 7 to lock or release the movement ...

Page 21: ...to CD ROM Drive and this will automatically display the following interface 1 Install PortableCaptureHD Click Install PortableCaptureHD and the installation wizard will guide you through the whole process 2 Full user s manual can be viewed by clicking User s Manual ...

Page 22: ...ope to your PC USB port start the software by clicking the icon generated on the desktop after installation and you will see the following screen pop up When the Microscope is disconnected from your PC USB port the following message will pop up ...

Page 23: ...22 7 Software Functions Capture Photo a Click Photo shortcut icon in the main menu bar b Click Capture Photo Capture Video a Click Video shortcut icon in the main menu bar b Click Capture Video ...

Page 24: ...ideo Click Timer shortcut icon in the main menu bar Under Timer photo you can set the start time interval time and total picture number Under Timer video you can set the start time interval time and total video number ...

Page 25: ...libration and Measurement Please make calibration before measurement Calibration Display Crossing from Options Crossing Microscope default at crossing on It s used to check the dial on the calibration ruler ...

Page 26: ...calibration ruler and then adjust the magnification till the picture is clear Take a picture for the selected area when the dial is parallel to the crossing as below 2 Double click on the picture to enter into measurement interface as below ...

Page 27: ...value Now a dialog will popup as below and you need to enter the exact value of the measurement sample into Actual dimension Then the software will automatically calibrate the magnification rate Click OK and the adjusted magnification rate will show in the upper right corner Remark The measured line should be paralleled ...

Page 28: ...27 4 Now you can use Any angle Line under Measurement icon to measure the value again If the value you measure by software is nearly the same as the exact value of the dial means the calibration finish ...

Page 29: ...sure any continuous desired length Simply click and drag from one point to other desired points and then release the click 3 Radius Circle Measurement Simply click and extend out to the desired radius the radius circumference and area of the circle will show up accordingly 4 Diameter Circle Measurement Simply click and extend out to the desired diameter the diameter circumference and area of the c...

Page 30: ...n rate and adjust focus to capture picture please calibrate the magnification rate again 1 Double click to open the picture Click Reset magnification Reset picture magnification as below And then start calibration again Calibration details please refer to page37 ...

Page 31: ...e and capture several pictures click on the picture to enter into measurement interface And click Set magnification Set picture magnification now a dialog will show up as below enter the magnification rate into the dialog and click OK ...

Page 32: ...ou want to use the same magnification rate to capture pictures just click Set magnification Set capture magnification Now all pictures will use the same magnification rate and you can start measurement directly ...

Page 33: ...u can draw or add a text on the picture and save for later analysis 1 Click icon to choose any kinds of drawing under the pull down manual as below 2 Click icon and set the font for the text in the popup dialogue as below ...

Page 34: ...ons Main Interface Icons Capture photo It s used to capture photo one by one Start Stop record video Timer for photo video Set the start time interval time and total photo video number Full screen mode Press ESC or double click to exit ...

Page 35: ...34 Main Menu File Photos Directory set the directory to store photos taken Videos Directory set the directory to store video taken ...

Page 36: ...e preview size Date Time set to display system date time on preview window Language choose different OSD language Crossing display cross on preview window Full screen mode enter into full screen Click ESC or double click to exit ...

Page 37: ...36 Capture Photo take a photo Video record a video clip ...

Page 38: ...37 Measurement Interface Instructions Save as Redo Copy to clipboard Draw Copy file Text note Previous Measurement Next Calibration Undo ...

Page 39: ...rical and electronic equipment should be disposed at the end of its life separately from your household waste There are separate collection systems for recycling in the EU For more information please contact the local authority or your retailer where you purchased the product ...

Page 40: ...t the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to ...

Reviews: