1. Package Contents
You should have received the following items inside of package:
-
UPS Unit
-
Startup Manual
-
Communication cable
-
Installation CD for monitoring software
2. Product Overview
Battery backup
receptacles
Status indicators
AC power input
Circuit breaker
Modem/phone/
Network surge
protection
Coaxial surge
protection (option)
USB communication
port
|
Power switch
3. Software Installation
1. Insert the included installation CD into CD-ROM drive and then
follow the on-screen instructions. If there no screen shows when
inserting the CD after 1 minute, please execute setup.exe for
initiating installation software.
2. Enter Serial No label pasted on the UPS unit to install the
software.
3. When your computer restarts, the monitoring software will appear
as a green plug icon located in the system tray, near the clock
4. Installation & Initial Startup
NOTE: Before installation, please inspect the unit. Be
sure that nothing inside the package is damaged.
Connect to Utility and Charging
Plug in the AC input cord to the wall
outlet. For the best results, suggest to
charge the battery at least 4 hours
before initial use. The unit charges its
battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the
rear panel of the UPS. Simply turn on the power
switch of UPS unit, then devices connected to
the UPS will be protected by UPS unit.
CAUTION: NEVER connect a laser printer or
scanner to the UPS unit. This may cause the
damage of the unit.
Connect Modem/Phone/Network to Surge Protection
Connect a single modem/phone/network line into surge-protected
“IN” outlet on the back panel of the UPS unit. Connect from “OUT”
outlet to the computer with phone line cable.
Connect Coax Protected Port
(For the model with coax protected
port only)
This coax protected port will protect your TV antenna, cable, and
network.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the
UPS unit by pressing again the power switch. You may check the
Status Indicators Section for the details.
Cold Start Function
When the UPS is off and there is no power utility, it's still possible to
cold start the UPS unit to power the loads.
5. Status Indicators
Status
Visual Indication
Alarm
AC Mode
Green Power On LED - On
Not applicable
On Battery
Yellow Batt. Mode LED - Flash
Sounding every 10 seconds
Low Battery
Yellow Batt. Mode LED - Flash
Sounding every second
Battery Replacement
Red Fault LED - On
Sounding every 2 seconds
Overload
Green Power On LED on
Sounding every 0.5 seconds
UPS Fault
Red Fault LED - On
Continuously sounding
WARNUNG: Dies ist eine USV der Klasse C2. In Wohnansiedlungen kann dieses Erzeugnis Funkstörungen hervorrufen, dann muss der Benutzer
zusätzliche Maßnahmen ergreifen.
WARNING: This is a UPS Class C2. In residential subdivision the product may cause harmful interference, then the users have to take additional
measures.
EN