SPECIFICATIONS 

Model number i101 

Capacity 100g 

Division 0.005g 

    Platter / Tray 

φ

100mm 

    Net/gross weight 

510/620g 

Standard carton: 29

×

22

×

14(cm

3

 

       

Package 

12 Units in one box: 60

×

45

×

45(cm

3

Operating Temperature 

0-40c (32-104

)) 

6

×

AA Size Batteries or AC/AC 

 

     

Power source 

Adapter 11V/150mA (optional) 

 

**SPECIAL WARNING** 

Cell-Phones, Cordless-Phones, and any radio-frequency device can 

cause temporary interference and cause the scale to temporarily not 

work properly.    Please do not use any electronic device near the i101.   

Just like in an Airplane, do not use your cell-phone near the scale 

when it is in use.    While there is NO risk of permanent damage to 

the scale, interference can cause an incorrect calibration or incorrect 

weight readings.   

 

 

 

 

 

 

 

 

 

 

 

 

 

i101 COMPACT SCALE 

 My Weigh iBalance SERIES 

i101 Generation 3 

 

INSTRUCTION MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This Document is Hosted by: www.oldwillknottscales.com

Summary of Contents for i101

Page 1: ...es and any radio frequency device can cause temporary interference and cause the scale to temporarily not work properly Please do not use any electronic device near the i101 Just like in an Airplane do not use your cell phone near the scale when it is in use While there is NO risk of permanent damage to the scale interference can cause an incorrect calibration or incorrect weight readings i101 COM...

Page 2: ...ight of these samples will show on the display 4 Press the UNIT key several times to put the scale in PCS mode the indicator should be on pcs 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary to put it in the correct sample size the sample size is the same as in step three 10 20 50or100 6 Press the UNIT key the display will show pass t...

Page 3: ...alibration is still incorrect repeat calibration but try it more slowly If calibration is repeatedly incorrect then 1 Replace the batteries 2 Try a more stable surface or vibration and interference free location 3 Be sure there is no static electricity on the scale use an anti static spray to remove static electricity FEATURES z Auto shut off optional Auto calibration z Auto zero tracking Auto bac...

Page 4: ...re is no cell or cordless phone interference and no vibrations 3 WEIGHING Before weighing Whenever possible please allow the scale to warm up for 30 seconds after first turning the power on so that the scale will function properly and accurately Error messages EEEE Overload Low battery Calibration may be required before weighing Calibration is rarely needed Read CALIBRATION first and if necessary ...

Reviews: