background image

Part #C-00170 

Rev. 8/29/17

S82 W18717  Gemini Drive;   Muskego, Wisconsin 53150

Phone:  (877) 622-2694

Fax:  (888) 679-3319

www.nabcoentrances.com

Technical Support:  (866) 622-8325

NABCO hours of Operation:  Monday to Friday  8:00 a.m.- 4:30 p.m. (Central Time) 

Model GT20 

Full Automatic and Low Energy Power Operated Doors

OWNER’S MANUAL

A Founding Member of: AAADM 

(American Association of Automatic Door Manufacturers)

WARNING

• Turn OFF all power to the Automatic Door if a Safety System is not working.

• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO 

trained technician. Failure to follow these practices may result in serious consequences.

• NEVER leave a Door operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: WARNING LABELS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
CHAPTER 3: SCOPE  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

SECTION 3.1: To the Customer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

SECTION 3.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

CHAPTER 4: GETTING STARTED   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

SECTION 4.3: Safety Standard Compliance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.4: Limited Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.5: Information Provided by Door Supplier  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

CHAPTER 5: GENERAL SAFETY   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
CHAPTER 6: OPERATION   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
CHAPTER 7: FULL AUTOMATIC SWING DOOR   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

SECTION 7.1: Sensors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 7.2: Sensor Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SECTION 7.3: Sensor Malfunctions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SECTION 7.4: Daily Safety Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

SECTION 7.5: Safety Decals for Full Automatic Swing Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

CHAPTER 8: LOW ENERGY SWING DOOR   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

Section 8.6: Daily Safety Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Section 8.7: Safety Decals for Low Energy Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Summary of Contents for GT20

Page 1: ...e practices may result in serious consequences NEVER leave a Door operating without all Safety detection systems operational Table of Contents CHAPTER 1 WARNING LABELS 2 CHAPTER 2 GENERAL SAFETY RECOM...

Page 2: ...e different materials are separated and recycled No particular measures are required for the protection of the environment However the relevant legal prescriptions applicable for the installation site...

Page 3: ...BCO ENTRANCES Inc s sole warranty This warranty does not cover loss or damages resulting from causes beyond the manufacturer s control misuse neglect accidents windstorms or other acts of God or acts...

Page 4: ...es are ignored 5 Exit Only an activation on the Interior Sensor Terminal will open the Door Chapter 7 FULL AUTOMATIC SWING DOOR SECTION 7 1 Sensors The Swing Door System can utilize a Sensor that acti...

Page 5: ...floor X X Surface of cart or trolley is not reflective enough to be detected Reflective tape or stickers can help Reflec ve S cker Trolley Bed DN 1568 Sensor is exposed to X X Steam X X Exhaust fume...

Page 6: ...out impact 4 Inspect the floor area It should be clean with no loose parts that might cause user to trip or fall Keep traffic path clear 5 Inspect door s overall condition The appropriate signage shou...

Page 7: ...mounted presence sensor as long as you are in the Safety area of the door it should not open Please see Figure 1 DN 1735 Swing Door Plan with Mo on Detector Ac va on and Overhead Presence Detec on Sa...

Page 8: ...n a different place 7 Repeat steps 2 6 several more times 7 4 5 Mat Activation Check for Safety Side of Swing Door If the Safety Mat is not working the door may swing toward you without stopping The p...

Page 9: ...afety Check is early in the morning while pedestrian traffic is still restricted from Sensor activating zones The purpose of a Daily Sensor Check is to ensure pedestrian safety and Owner protection 1...

Page 10: ...rly visible X X The sign shall be a minimum of 6 inches in diameter Black lettering shall be a minimum 5 8 inch tall on a yellow background White lettering shall be a minimum 1 2 inch tall on a blue b...