Summary of Contents for MULTISTATION 1000

Page 1: ...Multistation Single phase Line interactive UPS 1000VA INSTRUCTION MANUAL Uninterruptible Power Systems ...

Page 2: ...e manual in which you will find all the safety installation and commissioning instructions as they will serve for the UPS to last and work as long as possible This manual describes the operating principle and the associated protection functions This manual also contains information on the use of the equipment Follow the instructions and all warnings in this manual or on the product Do not connect ...

Page 3: ...nt different than above mentioned please refer to your reseller or to call Naicon Service assistance for information Don t cover device s air inlet avoid direct exposure to direct sunlight or install it close to heating sources in order to avoid any overheating of the unit Before cleaning the UPS disconnect it from the Mains To clean external surface please use only a dry cloth Don t use any liqui...

Page 4: ...n characteristics Microprocessor control for a higher reliability AVR FUNCTION Automatic Voltage Regulation Green Power function for energy saving Cold Start Autorestart function upon returning of Mains Light and compact Overload protection 2 1 Multifunction view 1 ON OFF switch 2 LED indicator A Green LED on normal operation electrical network is present B Yellow LED flashing operating from batte...

Page 5: ...nd the unit 3 To place the UPS at least 20cm far from any monitor or screen in order to avoid interference 3 3 Battery recharge The unit is shipped from the factory with a fully charged internal battery however it could be discharged during transportation so it has to be recharged before use To do this connect the unit to an appropriate power outlet and let the battery recharge for at least 6 hour...

Page 6: ... on front panel Continuous beep when Mains is present Overload on UPS Verify that load doesn t exceed the rating of the UPS Battery autonomy time in back up mode is short Overload on UPS Partially remove the load Battery voltage is very low Recharge the battery for at least 8hr Battery failure due to high ambient temperature or improper operation of the battery Replace the battery with the same ty...

Page 7: ...ree Recharge time 6 8 hours at 90 after deep discharge VISUAL INDICATORS AC Mode Green LED On Battery Mode Yellow LED flashing Failure Red LED On ACOUSTIC ALARMS Backup Mode A Beep every 10s Low Battery A Beep every 1s Overload A Beep every 0 5s Failure Continuous beep USB CHARGER Typical 5 0V 1 0A Max SWITCHING TIME Typical 2 6 ms PROTECTIONS Complete Against discharge overcharging overload input...

Page 8: ...aintenance and repair or replacement of parts subject to normal wear and tear Any modification or modification to the product without prior written permission from ELSIST to enhance performance than those described in the User and Maintenance Manual All costs of technical staff support and any transport from the customer s adress to Assistance Center and vice versa as well as all the risks involve...