INSTRUCTION MANUAL

NAMRON TERMOSTAT

TOUCH Z-WAVE 16A

Summary of Contents for TOUCH Z-WAVE 16A

Page 1: ...INSTRUCTION MANUAL NAMRON TERMOSTAT TOUCH Z WAVE 16A ...

Page 2: ...eter can also be configured through advance config parameter 10 1 Away 2 Auto 3 Manual 4 Drying 5 Off Standard EN 60730 1 2016 A1 EN IEC 60730 2 9 2019 A1 EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 60730 1 2016 A1 2019 EN 60730 2 19 2019 A1 2019 A2 2020 EN 50663 2017 ETSI EN 301 489 1V2 2 3 ETSI EN301 489 3V2 1 1 ETSI EN300 220 1 v3 1 1 ETSI EN300 220 2 V3 2 1 RED 2014 53 EU Certificate Z ...

Page 3: ...o the connection box by tightening the screws Make sure that the thermostat is fixed without deformation Suggested torque is 0 2 0 4Nm 2 0 4 1kgf cm NTC L L N N L N Floor temp sensor SR ZV9092A 4512744 Off mode Manual mode Auto mode Drying mode Floor temperature Away mode Weekdays Time shift button Mode button Set temperature Function button Monitor set Other set Included to a Z Wave network Sched...

Page 4: ...limitation The device will consider the mode as anti freeze mode the recommended temperature setting is 4 10 C 2 Auto Mode the device will control the heating system according to the configured time schedule or Z Wave protocol Energy_Save_Heating Setpoint 2 1 When configuration parameter 8 value set as 1 the device will control the temperature of energy save mode accord ing to the temperature set ...

Page 5: ...d lasts After Mode set the mode after the drying mode ends Remain shows the remaining time of the drying mode For configuration method and modification please refer to Automatic Mode Energy Save Mode Schedule 5 Off Mode this mode only enables the device to turn on the heating system when anti freezing mode is enabled and the device meets all required conditions otherwise the device will not work m...

Page 6: ...button for over 3 seconds or reset power of the device After cancel manually the relay will show heating forbidden icon within 120 seconds but other operations are allowed To prevent the undulation of sensor temperature when the sensor temperature is approaching the set temperature which will cause that the controller may keep switching on off the relay Here hysterersis enables the controller to c...

Page 7: ...rough Advance Config parameter 11 and 12 Other Set Temperature Compensation Device state after reset power of the device If set as last status device will go to the status before power failure after power on again If set as default device will go to default mode after power on again This parameter can also be configured through Advance Config parameter 4 Re power Status To ensure the safety of the...

Page 8: ...l be removed from the Z Wave network Select Reset then short press button the device will start reset Status will show Reset If there is no response from a gateway within 6 seconds or exclusion failed Status will show Fail If reset successfully Status will show Reset OK Note 1 if the device is excluded or reset successfully the Auto Mode Schedule will be reset to default value Note 2 the sent fram...

Page 9: ..._Away_Heating set away temperature ThermostatSetPoint V2 COMMAND_CLASS_SECURITY V1 COMMAND_CLASS_SECURITY_2 V1 COMMAND_CLASS_TRANSPORT_SERVICE V2 COMMAND_CLASS_SUPERVISION V1 YES V3 YES V1 YES V2 YES V2 YES V3 YES V1 YES V3 YES V2 YES V1 YES V1 YES V1 YES V1 YES V8 YES V3 COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STATE COMMAND_CLASS_THERMOSTAT_SETPOINT COMMAND_CLASS_ASSOCIAT...

Page 10: ...CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO V2 V1 V1 V1 V5 YES YES V2 YES V3 YES V1 EndPoint2 floor temperature sensor command list Group ID Description 1 5 NAME Lifeline Profile Max nodes AGI_LIFE_LINE 0x0001 1 Send Command Class DEVICE_RESET_LOCALLY_NOTIFICATION to associated devices of this group when factory reset the device 2 Send Command Class THERMOSTAT_SETPOINT_REPOR...

Page 11: ...evel 2 High Level 0x0A 10 1 1 Other Set Temperature control reference selection 1 room sensor 2 floor sensor 3 room floor sensor 0x04 4 1 1 Other Set Whether to recover to settings before power failure or power reset 0 use default settings 1 recover to settings before power failure or power reset 0x08 8 0 1 None Auto mode Energy save mode temperature schedule 0 use schedule set by user 1 use Energ...

Page 12: ...ld unit is W 0 disable to report 1 100 report when absolute threshold is 1 100 0x13 19 10 1 None When to report current change absolute threshold unit is 0 1A 0 disable to report 1 10 report when absolute threshold is 1 10 0x14 20 2 1 None When to report voltage change absolute threshold unit is 1 V 0 disable to report 1 10 report when absolute threshold is 1 10 0x17 23 0 1 Other Set This paramete...

Page 13: ...Namron AS Nedre kalbakkvei 88B 1081 Oslo Norway post namron com ...