background image

 

Using Your GEM-P400 Security System 

 AR

MED

STA

TU S

1    2    3    4      

Summary of Contents for GEMINI-P400

Page 1: ...1 Using Your GEM P400 Security System AR MED STATUS H 1 2 3 4 ...

Page 2: ...2 This page left blank intentionally ...

Page 3: ... and it is open the 1 on the keypad display will be lit If zone 2 is a motion detector and there is movement in that area 2 will light Depending upon the actual layout your security professional has chosen to properly protect your premises each zone may function a little differently The zone protecting your front door may be programmed as an Exit Entry zone to allow you time to enter the premises ...

Page 4: ... siren by pressing A followed by 1 The bell or siren will sound for 2 seconds and the battery will also be tested 2 Zone Test Walk throughout the premises opening each protected door or window and activating each motion sensor Check the keypad to see that each respective zone number displays in the window 3 Central Station Communication Test This test should only be performed on weekends or at a t...

Page 5: ...zone press B and the zone number to be bypassed and then Arm system Press C to reset Fire Zone clear miss entered codes reset Alarm Memory etc Numerical Keys 1 9 0 Used to enter User Codes Zone n u m b e r s etc Emergency Keys Press simultaneously to signal an emergency condition Press 8 G for Auxiliary Emergency or 9 G for Police Emergency Programmable Zone Lights 1 through 4 will light to indica...

Page 6: ...e optional Easy Arm feature allows the system to be armed by simply pressing D This will allow the easy arming of the system by someone who is not a regular system user Bypassing Zones If an open zone cannot be immediately fixed it can be left unprotected or bypassed while the rest of the system is Armed To bypass a zone 1 Press B followed by the number of the zone to be bypassed The bypassed zone...

Page 7: ...ning when all family members are home for the night Instant Mode can be activated at any time after the system has been armed The red Armed light will flash rapidly while in the Instant Mode Easy Exit optional Your System may have been programmed to allow Easy Exit which allows a user to exit the premises with the system armed By pressing A followed by 0 the protection is removed from the Exit Ent...

Page 8: ...nstaller Police Emergency Simultaneously press9 G to sound a police emergency alarm and to alert the central station of a Police emergency if so programmed Emergency Conditions Ambush Alarm In the event that you are forced by an intruder to disarm your system the ambush alarm can be activated Disarming the system with the Ambush Code will cause the system to disarm and simultaneously send a silent...

Page 9: ...ion If the Red Armed light is flashing rapidly an alarm occurred while you were away Proceed with caution For your own protection leave immediately and call authorities from a neighbor s phone Silencing an Alarm In the event that the system goes into alarm due to a violated burglary zone the siren and the keypad sounder will activate and the number of the zone in alarm will flash in the display To...

Page 10: ...st very 24 hours Access Output If programmed pressing A followed by 3 will activate the Access Output which may be configured to open a door strike turn on lighting or activate some other special feature your installer has provided Display System Trouble Pressing A followed by 4 when TROUBLE H is lit will cause the system to display any current system troubles Pressing E will exit the Display Syst...

Page 11: ...ight ON System Trouble Condition Action 1 Beep 1 AC Power Failure This trouble will occur if AC power is not present Make sure system transformer is plugged into AC receptacle and check the circuit breaker otherwise call installing company for service 1 Beep 2 Low Battery If there has been a recent power failure the battery may be partially depleted and must be recharged by the control panel If th...

Page 12: ...o the number of the lit zone light The replacement battery for the GEM Trans2 door window transmitter GEM PIR motion detector and GEM GB glass break detector is the Duracell DL123A 3 volt lithium 2 required for the GEM PIR and GEM GB The GEM DT Dual Technology Sensor requires 4 C cell alkaline batteries Warning Replace batteries only with the same type as specified above Use of another battery may...

Page 13: ... the User 2 code The keypad will beep 2 times and the corresponding Zone will flash to indicate the user number you are about to program 2 Press in the 4 digits of the new User 2 code the keypad will beep 4 times 3 If there are more user codes to be programmed return to step 1 above otherwise go to Exiting the User Program Mode below Erasing a User Code 1 Press the User number to be erased The key...

Page 14: ...n opened while the system is disarmed Easy Exit Allows an occupant to leave the premises without disarming the system Pressing A and then 0 while the system is armed will permit exit by removing the protection on the Exit Entry door for 3 minutes Exit Entry Delay The amount of time you are allowed to enter and leave the premises when the system is armed Exit Entry Zone A zone which will allow you ...

Page 15: ...15 Notes ...

Page 16: ...d and insured to NAPCO After repair or replacement NAPCO assumes the cost of returning products under warranty NAPCO shall have no obligation under this warranty or otherwise if the product has been repaired by others improperly installed improperly used abused altered damaged subjected to accident nuisance flood fire or acts of God or on which any serial numbers have been altered defaced or remov...