AUB / GZ600KT Blower Installation Instructions (Side)
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686
• www.napoleonfireplaces.com
W415-1680 / B / 08.09.17
!
WARNING
• Do not touch safety screen until cooled.
• Allow safety screen to cool completely before any maintenance, as it will remain hot after appliance is no longer
operating.
• Ensure the appliance is completely cool before starting installation.
• To avoid danger of suffocation keep the packaging bag away from babies and children. Do not use in cribs, bed,
carriages, or play pens. This bag is not a toy. Knot before throwing away.
BLOWER
MOUNTING TAB
LOCATION
SCREW
LOCATION
H.
Place the control module back into its original position. Ensure the transformer is plugged into the outlet of the
electrical box.
I.
Install the variable speed switch (VSS) mounting bracket into position then reinstall the two previously removed screws,
refer to Figure 3. To install the variable speed switch, the mounting bracket will first need to be installed. Remove the two
screws securing the piezo ignitor switch bracket in place.
J.
The VSS will need to be disassembled to secure to the VSS bracket for installation. Place the VSS through the mounting
bracket using the lock washer to secure it in place. Take the variable speed switch knob and install into position. (Refer to
Figure 3.)
BLOWER
BLOWER
MOUNTING
TAB
REAR VIEW
A.
Remove the screen by lifting it up and off of the appliance.
B.
Remove the door from the appliance by releasing the door latches.
C.
It may be necessary to move the control module aside during blower installation. (Electronic Only)
D.
Attach the two 1/4” connectors (black and white) from the wire harness to the thermodisc.
E.
Attach the two 1/4” connectors (black and red) from the wire harness to the blower.
F.
Install the clear bumpers supplied onto the bottom of the blower to avoid the blower rubbing against the floor of the
appliance.
G.
Pivot the blower into the bottom of the appliance. Ensure the gasket remains in place between the blower and outer shell
while sliding the blower against the left side of outer shell into the blower mounting tab. Secure in place using one screw,
see Figures 1 and 2.
NOTE: WITH THE WIRE CLIP SUPPLIED, ENSURE ALL WIRES REMAIN CLEAR OF THE BLOWER.
K.
Plug the connector from the variable speed switch to the matching connection on the wire harness.
L.
Bend the thermal disc bracket 90 degrees and secure it to the firebox mounting tab using the two screws
supplied, refer to Figure 4. Ensure that the thermal disc is in contact with the firebox base and that the wire
harness is properly attached.
M.
Plug the power cord from the blower into the electrical box.
NOTE: The blower is thermally activated, so when it is turned on, it will automatically start approximately 15 minutes after
lighting the appliance and will run for approximately 30 minutes after the appliance has been turned off.
FIGURE 3
VSS
BRACKET
PIEZO IGNITOR
BRACKET
FIGURE 4
THERMAL DISC
BRACKET
THERMAL DISC
MOUNTING TAB
FIREBOX BASE
BLOWER
BLOWER
MOUNTING
TAB
REAR VIEW
FIGURE 2