The ISC-178x are high-performance smart cameras powered by a 1.58 GHz dual-core Intel
Celeron processor. The combination of the onboard processor with a CMOS image sensor
provides an easily distributed all-in-one system.

In addition to high-performance image acquisition and processing, you can use built-in digital
I/O and industrial communication options for dynamic, real-time communication and
integration with industrial automation devices including programmable logic controllers
(PLCs), human machine interfaces (HMIs), robotics, sensors, and industrial machinery.

Safety Guidelines

Caution

 

Observe all instructions and cautions in the user documentation. Using

the ISC-178x in a manner not specified can damage the model and compromise the
built-in safety protection. Return damaged models to NI for repair.

Caution

 

The case of the ISC-178x can become hot and should not be touched

while operating. Always allow hot surfaces to cool before touching the ISC-178x.

Caution

 

The ISC-178x must be mounted to a support using the provided mounting

holes before operating. Refer to the 

ISC-178x User Manual

 for mounting

information.

Caution

 

There are no serviceable parts inside the ISC-178x.

Caution

 

 The ISC-178x can only be powered using a 24 VDC power source.

Caution

 

Do not use at altitudes exceeding 2000 meters.

Caution

 

To maintain IP67 conformity, all unused connectors on the ISC-178x

must be capped and the IP lens cover must be screwed firmly into place.

Caution

 

For indoor use only.

Summary of Contents for ISC-178 Series

Page 1: ...uctions and cautions in the user documentation Using the ISC 178x in a manner not specified can damage the model and compromise the built in safety protection Return damaged models to NI for repair Caution The case of the ISC 178x can become hot and should not be touched while operating Always allow hot surfaces to cool before touching the ISC 178x Caution The ISC 178x must be mounted to a support...

Page 2: ...ent Operate the device only at or below the pollution degree stated in the specifications Pollution consists of any foreign matter solid liquid or gas that may reduce dielectric strength or surface resistivity The following is a description of pollution degrees Pollution Degree 1 No pollution or only dry nonconductive pollution occurs The pollution has no effect Pollution Degree 2 Normally only no...

Page 3: ...ter Kit for ISC 178x Smart Cameras NI part number 785830 02 X Code M12 to RJ45 Network Cable 5 m NI part number 145230A 05 A Code M12 to A Code M12 Power and I O Cable 3 m NI part number 145232A 03 M12 to VGA USB Splitter Cable 1 m NI part number 782022 01 Power and I O Accessory for ISC 178x Smart Camera NI part number 145227A 01 Power Supply PS 10 100 VAC to 240 VAC 24 VDC 5A NI part number 7826...

Page 4: ...mage sensor 3 C mount lens mount 4 Varioptic liquid lens connector Figure 2 ISC 178x Connectors Power Status User 100 1G 1 2 3 4 1 LED indicators 2 Power and I O connector 3 VGA and USB connector 4 Network connector 4 ni com ISC 178x Getting Started Guide ...

Page 5: ... for isolated inputs 7 Iso In 2 General purpose isolated input 8 Iso In 3 NI Linux Real Time Reserved for safe mode Windows General purpose isolated input 9 Iso In 1 General purpose isolated input 10 Iso Out 0 General purpose isolated output positive 11 C System power and analog reference common 12 Iso Out 1 General purpose isolated output positive The following NI power and I O cables are availab...

Page 6: ...Power and I O Accessory for ISC 178x Smart Cameras User Manual for more information 1 Verify the power source is turned off 2 Connect and secure the M12 connector of the terminal block cable to the Power and I O connector on the smart camera 3 Connect and secure the other end of the terminal block cable to the terminal block 4 Connect any additional I O signals necessary for your application to th...

Page 7: ... liquid lens connector on the ISC 178x Once the connector is in place use the tweezers to press firmly on either side of the wires to ensure a good connection 8 Slide the lens cover over the lens and screw it into the ISC 178x housing until it is firmly in place The lens cover must be in place for IP67 conformity 9 Reconnect the power to the ISC 178x When the ISC 178x powers on with a compatible l...

Page 8: ...network 1 Verify the development computer is powered on and connected to the network 2 Connect one end of an M12 Ethernet cable to the network connector on the ISC 178x 3 Connect the free end of the Ethernet cable to an Ethernet switch or network device 4 Verify the 100 1G LED on the smart camera is on or blinking The device negotiates an IP address when connected to a network with a DHCP server o...

Page 9: ... c Click Add Remove Software on the MAX toolbar to launch the LabVIEW Real Time Software Wizard d Enter admin as the username and leave the password field blank e Select Vision Software under the version of LabVIEW Real Time you are using f Click Next g Select any additional add ons you would like to install to the ISC 178x h Click Next Review the list of software to install i Click Next to begin ...

Page 10: ...ra is on or blinking Note By default the operating system automatically attempts to connect to the network using DHCP If it is unable to initiate a DHCP connection it connects to the network with a link local IP address 169 254 x x Installing NI IMAQdx Driver Software Before using the ISC 178x install other National Instruments software such as application development environments and then install...

Page 11: ...th the ISC 178x and the development computer are properly connected to the network The Power LED should be lit green the Status LED should be lit orange or green and the 100 1G LED should flash green when refreshing the list of devices in MAX Ensure you are connecting to the ISC 178x from a Windows development computer with NI IMAQdx installed The ISC 178x may have been configured on another netwo...

Page 12: ...DP Ports Used by the ISC 178x Port Type Details 3580 TCP UDP Reserved as nati svrloc NATI ServiceLocator Used by MAX to locate remote targets 7749 TCP Used for remote image display not reserved 7750 TCP Used for NI IMAQdx remote configuration not reserved 3363 TCP UDP Reserved as nati vi server NATI VI Server Used by Vision Builder AI to configure a remote target If your firewall is controlled rem...

Page 13: ...ate Limit attribute Related Information Installing NI IMAQdx on page 9 LED Indications The ISC 178x indicates specific error conditions by flashing the Power Status and User LEDs Table 4 LED Indications Power LED Status LED User LED Indication Off Off Off The ISC 178x does not have power Red Red Red The ISC 178x is powered but is not responding Red Orange Initialization error Orange Orange Red bli...

Page 14: ...he Power and I O Accessory for ISC 178x Smart Cameras ISC 178x User Manual Contains detailed electrical and mechanical information about the ISC 178x ISC 1780 Specifications Contains detailed specifications for the ISC 1780 ISC 1781 Specifications Contains detailed specifications for the ISC 1781 ISC 1782 Specifications Contains detailed specifications for the ISC 1782 ISC 1783 Specifications Cont...

Page 15: ...For support in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For support outside the United States visit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information ISC 178x Getting Started Guide National Instruments 15 ...

Page 16: ...nts EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY E...

Reviews: