background image

GETTING STARTED GUIDE

NI 9265

4-Channel, 0 mA to 20 mA, 16-Bit Analog
Output Module

This document explains how to connect to the NI 9265.

Summary of Contents for NI 9265

Page 1: ...GETTING STARTED GUIDE NI 9265 4 Channel 0 mA to 20 mA 16 Bit Analog Output Module This document explains how to connect to the NI 9265...

Page 2: ...for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9265 only as described in this document Caution Do not operate the NI 92...

Page 3: ...earth ground Vsup to earth ground or COM to earth ground Continuous up to 2 000 m altitude 250 Vrms Measurement Category II up to 5 000 m altitude 60 VDC Measurement Category I 1 The maximum voltage t...

Page 4: ...equipment This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment...

Page 5: ...ified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Ensure that devices and circuits connected...

Page 6: ...hese guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not r...

Page 7: ...I 9265 is marked II 3G and is suitable for use in Zone 2 hazardous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9265 in Gas Group IIC hazardous locations you must use the...

Page 8: ...ents and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in indu...

Page 9: ...ister certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for ma...

Page 10: ...IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Note Refer to the device datasheet on ni com manu...

Page 11: ...COM2 AO3 COM3 Vsup Power Supply COM 0 1 2 3 4 5 6 7 8 9 Note You must use 2 wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9265 NI 9265...

Page 12: ...internally connected to the isolated ground reference of the module The NI 9265 also has a terminal for an external power supply Vsup and an external power supply common terminal Power Supply COM Con...

Page 13: ...Supply COM Load Protection DC DC External Power Supply Connecting an External Power Supply You must connect an external power supply to the NI 9265 This power supply provides the current for the devic...

Page 14: ...to high vibration NI recommends that you follow these guidelines to protect connections to the NI 9265 Use ferrules to terminate wires to the detachable connector Use the NI 9927 backshell kit with th...

Page 15: ...ompactRIO NI CompactDAQ RELATED INFORMATION NI 9265 Datasheet NI RIO Help LabVIEW FPGA Help NI 9265 Datasheet NI DAQmx Help LabVIEW Help C Series Documentation Resources ni com info cseriesdoc Service...

Page 16: ...National Instruments product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of comp...

Page 17: ...in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglob...

Page 18: ...d third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance pol...