Page 1: ...NI 9795...

Page 2: ...9795 WSN C Series Gateway This guide describes how to install configure and verify the National Instruments 9795 Wireless Sensor Network WSN C Series gateway NI WSN nodes and NI software Figure 1 NI 9...

Page 3: ...unning Windows and NI software a NI WSN gateway NI WSN 32xx node s a NI CompactRIO chassis as shown in Figure 2 and an Ethernet network 1 NI WSN 32xx Nodes Running Application Software 2 NI CompactRIO...

Page 4: ...Wireless Sensor Network Module Optional Includes NI WSN driver software NI RIO driver software NI WSN driver software which contains NI Measurement Automation Explorer MAX NI CompactRIO controller an...

Page 5: ...ted to NI WSN refer to ni com info and enter rdwsnrd In addition to this guide the following documents may be useful when configuring your NI WSN system Documentation for your NI CompactRIO controller...

Page 6: ...tion to ensure compliance with safety EMC and environmental regulations Step 1 Unpack and Install the Device Remove the device from the packaging and inspect it Contact NI if the device appears damage...

Page 7: ...in the NI CompactRIO chassis Figure 3 Inserting the NI 9795 into the C Series Chassis Step 2 Install NI WSN Software on the Host PC For information about which software version supports your device go...

Page 8: ...nstall NI WSN Software on NI CompactRIO Controller Complete the following steps to install NI WSN software on the NI CompactRIO controller for NI 9795 WSN C Series gateway 1 Launch MAX 2 Expand Remote...

Page 9: ...s d Click Next 7 Click Next on the Review Selections dialog box The software then installs to the target and the target reboots Step 4 Configuring the NI WSN System You must configure the NI WSN devic...

Page 10: ...Node 5 In the Add Node dialog box a Select the Type b Enter the NI WSN 32xx device serial number which is listed on the sticker on the underside of the device and an ID Number number between 1 and 50...

Page 11: ...0 ni com 7 After the nodes are added in MAX the nodes connect automatically when they are in range of a gateway Note If your node does not connect automatically refer to ni com info and enter exxhqv f...

Page 12: ...e documentation Step 6 Start Using the NI WSN System To start using the NI WSN system complete the following steps 1 Open a new LabVIEW project If the NI CompactRIO controller is on the local subnet c...

Page 13: ...gateway can only be used in a NI CompactRIO chassis that supports the RIO Scan Interface RSI For more information go to ni com info and enter rdsoftwareversion To use RSI and FPGA at the same time wit...

Page 14: ...ou want to use Click OK and then select Scan Interface as the Programming Mode of the NI CompactRIO chassis and click Continue Note The NI 9795 WSN C Series gateway can only be used in a NI CompactRIO...

Page 15: ...9795 Getting Started Guide 14 ni com 4 Expand the listing for the Wireless Sensor Network in the NI LabVIEW project to see the NI WSN 32xx nodes connected to it Expand each node to view the I O variab...

Page 16: ...configuring the NI WSN system in NI LabVIEW select Help LabVIEW Help and enter WSN Programming Examples NI LabVIEW includes example programs to help you develop an application To locate NI LabVIEW exa...

Page 17: ...e at ni com patents Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs...