background image

USER GUIDE

NI PXIe-1062Q Power Supply 
Shuttle

The NI PXIe-1062Q power supply shuttle is a replacement part for the 
NI PXIe-1062Q chassis.

Caution

This power supply is not compatible with any other National Instruments chassis.

Introduction

To minimize downtime caused by a power-supply failure, the 
NI PXIe-1062Q chassis has a modular power supply shuttle. This power 
supply shuttle includes the chassis power supply, cooling fans, and 
fan-control circuitry. Key features of the power supply shuttle include:

Universal AC input with automatic voltage and frequency ranging

Over-current protection via push-reset circuit breaker

Remote power monitoring and inhibit via a rear-panel connector

Temperature-sensing module that can adjust fan speed based on 
air-intake temperature to minimize audible noise

Circuitry to control a front-panel LED that indicates power supply 
failure

Unpacking

Carefully inspect the shipping container and the power supply shuttle for 
damage. Check for visible damage to the metal work. Check to make sure 
all handles, hardware, and switches are undamaged. Visually inspect the 
inside of the shuttle for any possible damage, debris, or detached 
components. If damage appears to have been caused during shipment, file 
a claim with the carrier. Retain the packing material for possible inspection 
and/or reshipment.

Summary of Contents for NI PXIe-1062Q

Page 1: ...ging Over current protection via push reset circuit breaker Remote power monitoring and inhibit via a rear panel connector Temperature sensing module that can adjust fan speed based on air intake temp...

Page 2: ...nit being repaired NI PXIe 1062Q power supply shuttle Read Me First Safety and Radio Frequency Interference NI PXIe 1062Q User Manual provided with the chassis also available at ni com support 1 Phill...

Page 3: ...ree environment Observe standard handling precautions for static sensitive devices while servicing the chassis Always wear a grounded wrist strap or equivalent while servicing the chassis Caution Alwa...

Page 4: ...on the back of the chassis Identify the eight mounting screws that attach the power supply shuttle to the chassis Refer to Figure 1 for the mounting screw locations Using a Phillips screwdriver remove...

Page 5: ...g screw Refer to Figure 1 to locate the chassis grounding screw To connect the safety ground complete the following steps 1 Connect a 16 AWG 1 3 mm wire to the chassis grounding screw using a groundin...

Page 6: ...ply to provide DC power to the CompactPCI PXI backplane DC Output DC current capacity IMP Notes Maximum combined 3 3 V 5 V and 12 V power is 345 W Maximum total power is 353 6 W The maximum power diss...

Page 7: ...V Clamped at 26 to 29 V difference between 12 and 12 V outputs Power supply shuttle MTTR Replacement in under 5 minutes Slot 5 V V I O 3 3 V 12 V 12 V 5 VAUX System Controller Slot 9 A 0 A 9 A 11 A 0...

Page 8: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: