NI SCXI -1366 Installation Guide

Terminal Block for the NI SCXI-1166

This guide describes how to install and connect signals to the 
National Instruments SCXI-1366 terminal block. Refer to the 

NI Switches 

Getting Started Guide

 to determine when to install the terminal block.

Introduction 

The SCXI-1366 terminal block installs in front of the SCXI-1166 switch 
module and has screw terminals that provide access to each of the 32 relays. 
Connections for the trigger output and trigger input signals also are 
available. 

Caution

This terminal block is rated for Measurement Category I and intended to carry 

signal voltages no greater than 150 V. This module can withstand up to 800 V impulse 
voltage. Do not use this module for connection to signals or for measurements within 
Categories II, III, or IV. Do not connect to MAINS supply circuits (e.g., wall outlets) of 
115 or 230 VAC. Refer to the 

NI Switches Getting Started Guide

 for more information on 

measurement categories.

When hazardous voltages (>42.4 V

pk

/60 VDC) are present on any relay terminal, safety 

low-voltage (

42.4 V

pk

/60 VDC) cannot be connected to any other relay terminal.

Conventions

The following conventions are used in this guide:

This icon denotes a note, which alerts you to important information.

This icon denotes a caution, which advises you of precautions to take to 
avoid injury, data loss, or a system crash.

italic

Italic text denotes variables, emphasis, a cross reference, or an introduction 
to a key concept. This font also denotes text that is a placeholder for a word 
or value that you must supply.

ni.com

Summary of Contents for NI SCXI -1366

Page 1: ...utput and trigger input signals also are available Caution This terminal block is rated for Measurement Category I and intended to carry signal voltages no greater than 150 V This module can withstand...

Page 2: ...antistatic package to a metal part of the chassis before you remove the terminal block from the package Remove the terminal block from the package and inspect the terminal block for loose components...

Page 3: ...leaving plenty of space for the signal cables 4 Pull the signal cables at least one foot through the strain relief opening shown in Figure 1 5 Connect the safety earth ground to the safety ground lug...

Page 4: ...i com Figure 1 SCXI 1366 Terminal Block 1 Strain Relief Opening 2 Safety Ground Lug 3 Strain Relief Bar 4 Terminal Block Top Cover 5 Screw Terminals 6 Rear Connector 7 Thumbscrews 8 10 32 3 4 Inch Scr...

Page 5: ...H 23 N O 150 VDC 125 VRMS MAX 5 A MAX 150 VDC 125 VRMS MAX 5 A MAX 150 VDC 125 VRMS MAX 5 A MAX N C CH 15 CH 25 CH 26 CH 27 CH 28 CH 29 CH 30 CH 24 O C M CH 19 M O C CH 11 C M O CH 9 C N C N N CH 8 M...

Page 6: ...e following steps 1 Connect the terminal block front connectors to its mating connectors on the terminal block 2 Tighten the top and bottom thumbscrews on the back of the terminal block rear panel to...

Page 7: ...55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity EN 61326 1997 A2 2001 Table 1 EMC EMI CE C Tick and FCC Part 15 Class A Compliant Note For EMC compliance you must operate this device with shi...

Reviews: