background image

GETTING STARTED GUIDE

NI PXIe-4610

Power Amplifier

This document explains how to install, configure, and set up the NI PXIe-4610 power amplifier. 
NI-DAQmx 9.8 has added support for the NI PXIe-4610 device. To download the NI-DAQmx 
driver, visit 

ni.com/info

 and enter the Info Code 

daqmx

.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for 
electromagnetic compatibility (EMC) as stated in the product specifications. These requirements 
and limits are designed to provide reasonable protection against harmful interference when the 
product is operated in its intended operational electromagnetic environment. 

This product is intended for use in industrial locations. There is no guarantee that harmful 
interference will not occur in a particular installation, when the product is connected to a test 
object, or if the product is used in residential areas. To minimize the potential for the product to 
cause interference to radio and television reception or to experience unacceptable performance 
degradation, install and use this product in strict accordance with the instructions in the product 
documentation.

Furthermore, any changes or modifications to the product not expressly approved by National 
Instruments could void your authority to operate it under your local regulatory rules.

Caution

This product may become more sensitive to electromagnetic disturbances 

in the operational environment when test leads are attached or when connected to a 
test object.

Caution

To ensure the specified EMC performance, operate this product only with 

shielded cables and accessories.

Caution

To ensure the specified EMC performance, the length of all I/O cables 

must be no longer than 3 m (10 ft).

Caution

Using the NI PXIe-4610 in a manner not described in this document may 

impair the protection the NI PXIe-4610 provides. 

ni.com/manuals

Deutsch

Français

Summary of Contents for PXIe-4610

Page 1: ...d to a test object or if the product is used in residential areas To minimize the potential for the product to cause interference to radio and television reception or to experience unacceptable perfor...

Page 2: ...device for loose components or any other sign of damage Notify NI if the device appears damaged in any way Do not install a damaged module into your system Store the module in the antistatic package w...

Page 3: ...on 4 When installation completes select Restart in the dialog box that asks if you want to restart shut down or restart later Install the Hardware You must install the software before using the hardwa...

Page 4: ...sis 11 Power on the chassis Configure the Hardware in MAX Use Measurement Automation Explorer MAX to configure your National Instruments hardware MAX informs other programs about which devices reside...

Page 5: ...fied 10X option button for each channel you want to enable Connect a Signal Source to the NI PXIe 4610 Input You can connect ground referenced and floating signal sources to the NI PXIe 4610 inputs Re...

Page 6: ...ground referenced You can connect floating loads and balanced ground referenced loads to the NI PXIe 4610 outputs Refer to Figure 8 for the NI PXIe 4610 front panel Note Refer to the NI PXIe 4610 Spec...

Page 7: ...NI PXIe 4610 outputs Note Connecting an unbalanced ground referenced load to an NI PXIe 4610 output introduces an unbalanced ground loop that may degrade the dynamic performance of the amplifier Caut...

Page 8: ...8 ni com NI PXIe 4610 Power Amplifier Getting Started Guide Figure 8 NI PXIe 4610 Front Panel...

Page 9: ...with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You ca...

Page 10: ...ruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can find...

Reviews: