INSTALLATION GUIDE

SCXI -1314T TEDS Bridge Sensor 
Terminal Block

This guide describes how to install and use the SCXI-1314T terminal block 
with the SCXI-1520 module and hardware Transducer Electronic Data 
Sheet (TEDS)-enabled bridge sensors (IEEE-P1451.4 Class 2).

The SCXI-1314T terminal block works with the SCXI-1520 universal 
strain/bridge sensor module to conveniently connect hardware TEDS smart 
sensors using RJ-50 10 position/10 conductor (10p10c) modular plugs. 
There are 10 pins arranged in eight modular jacks. Each jack corresponds 
to one of the eight channels available on the SCXI-1520. For a complete 
description of the use and operation of the SCXI-1520 module, refer to the 

SCXI-1520 User Manual

.

Conventions

The following conventions are used in this manual:

»

The 

»

 symbol leads you through nested menu items and dialog box options 

to a final action. The sequence 

File»Page Setup»Options

 directs you to 

pull down the 

File

 menu, select the 

Page Setup

 item, and select 

Options

 

from the last dialog box.

This icon denotes a note, which alerts you to important information.

When this icon is marked on the product, refer to the 

Read Me First: Safety 

and Radio-Frequency Interference

 document, shipped with the product, for 

precautions to take.

When symbol is marked on a product, it denotes a warning advising you to 
take precautions to avoid electrical shock.

When symbol is marked on a product, it denotes a component that may be 
hot. Touching this component may result in bodily injury.

Summary of Contents for SCXI-1314T

Page 1: ...ration of the SCXI 1520 module refer to the SCXI 1520 User Manual Conventions The following conventions are used in this manual The symbol leads you through nested menu items and dialog box options to...

Page 2: ...ming examples and syntax examples This font is also used for the proper names of disk drives paths directories programs subprograms subroutines device names functions operations variables filenames an...

Page 3: ...he Read Me First Safety and Radio Frequency Interference document before removing equipment covers or connecting or disconnecting any signal wires Each channel input contains pins that connect to the...

Page 4: ...ure 1 SCXI 1314T Parts Locator Diagram 2 Use long nose pliers to carefully remove the socketed 100 k precision resistors Note To avoid damaging the precision resistors pull the leads directly alternat...

Page 5: ...e sockets indicated in Figure 2 Figure 2 SCXI 1314T Shunt Resistor Sockets 5 Reinstall the top cover and tighten the top cover screws 6 Refer to the SCXI Quick Start Guide to finish installing the SCX...

Page 6: ...alf and full bridge TEDS sensor bridge configurations available for use with the SCXI 1314T Table 1 Channel Signal Names RJ 50 10p10c Modular Plug and SCXI 1314T Receptacle Pin Numbers Pin Signal Name...

Page 7: ...re 3 Quarter Bridge Circuit Diagram The following symbols apply to the circuit diagram and equations R1 and R2 are half bridge completion resistors R3 is the quarter bridge completion resistor dummy r...

Page 8: ...the lead resistance VAI is the measured voltage VRS is the remote sense measured excitation voltage T is the TEDS data transmission line T is the TEDS ground reference Note For greatest calibration a...

Page 9: ...al for more information Figure 4 Half Bridge Circuit Diagram The following symbols apply to the circuit diagram and equations R1 and R2 are half bridge completion resistors R3 and R4 are the active me...

Page 10: ...stance VAI is the measured voltage VRS is the remote sense measured excitation voltage T is the TEDS data transmission line T is the TEDS ground reference Note For greatest calibration accuracy use se...

Page 11: ...R4 are active measuring elements VEX is the excitation voltage RL is the lead resistance VAI is the measured voltage VRS is the remote sense measured excitation voltage T is the TEDS data transmissio...

Page 12: ...or your application The recommended twisted pairs are as follows AI AI RS RS EX EX T T SCA SCA 3 Expose 12 7 to 15 9 mm 0 500 to 0 625 in of signal wires without stripping the insulation as shown in F...

Page 13: ...gure 7 Inserting Signal Wires into RJ 50 10p10c Modular Plug 7 Crimp the terminal using an RJ 50 terminal crimper as shown in Figure 8 Figure 8 Crimping the RJ 50 10p10c Modular Plug 1 Insulation 2 Sh...

Page 14: ...application Attach the cable shielding to the TEDS sensor as shown in Figure 9 Figure 9 Attach the Shielding to the TEDS Sensor Connect the cable shielding to the metal grounding portion of the RJ 50...

Page 15: ...ter you have grounded your application insert the RJ 50 10p10c modular plugs into the SCXI 1314T Note Improperly grounding the shielding causes signal noise 10 Refer to the SCXI Quick Start Guide to p...

Page 16: ...rdted6 rdrscl Specifications All specifications are typical at 25 C unless otherwise specified Electrical Shunt calibration resistors RN 55 style 1 4 W Accuracy of resistors 100 k shunt calibration re...

Page 17: ...another Installation Category I Digital signals Channel to earth 0 to 5 V of one another Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing...

Page 18: ...iance The SCXI 1317 terminal block meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic Compat...

Page 19: ...s mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the pa...