NAUSICAA WEIGHING 

SYSTEM

ACCURACY : 100 g

WEIGHT CAPACITY : 300 kg

v03.04/17

User Manual : NAUSICAA WEIGHING SYSTEM

Distributed by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)

www.nausicaa-medical.eu

Summary of Contents for Weighing System

Page 1: ...IGHING SYSTEM ACCURACY 100 g WEIGHT CAPACITY 300 kg v03 04 17 User Manual NAUSICAA WEIGHING SYSTEM Distributed by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer www nausicaa...

Page 2: ...ning Maintenance Troubleshooting Guide Battery Change Warranty 1 3 4 7 8 9 10 11 12 13 Manufacturer EXPONDO GmbH An den Treptowers 1 D 12435 BERLIN ALLEMAGNE Distributed by NAUSICAA M dical S A S User...

Page 3: ...LING Step 1 Disassemble the spreader bar and its vertical axis 1 1 User Manual NAUSICAA WEIGHING SYSTEM Distributed by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer Step 2B...

Page 4: ...on the lower part of the weighing system with the vertical axis and its fixation 3 Step 4 Close the spreader bar protection 4 2 User Manual NAUSICAA WEIGHING SYSTEM Distributed by NAUSICAA M dical S...

Page 5: ...an be raised by the weighing system Do not force the controls and features of the weighing system they are all easy to use and do not require strength The weighing system must be handled with care whe...

Page 6: ...of 30 kg Step 2 POWER OFF Press _ for 1 second to power off scale Display shows power off message 1 2 8 8 8 8 8 0 0 oFF STB ZERO TARE HOLD STB ZERO STB 4 Instructions for Use The weighing system must...

Page 7: ...weight resumes in gross mode 3 100 6 100 6 0 0 STB STB STB TARE Step 4 HOLD Press _ to lock the display HOLD shows and display is frozen Press _ again to resume display HOLD hides and display resume...

Page 8: ...rns zero If weight is tared or not stable or held zero is not allowed This operation is available for a load inferior to 6 kg 5 6 10 0 22 0 98 0 STB STB STB 100 6 0 0 STB STB TARE ZERO HOLD UNIT 6 Use...

Page 9: ...or not Push to exit the setting mode Step 7 SETTING 1 AUTO OFF oFF Press _ and _ simultaneously and hold two buttons for 1 second to enter Setting Mode Press _ to enter Auto Off option and press _ to...

Page 10: ...er medical and non medical devices check that the combination of these products is allowed and can be used together safely 5 Assembly commissioning maintenance and repair of the Weighing System should...

Page 11: ...in one operation Respecting the following operation Cleaning is carried out by means of a cloth impregnated with a disinfectant solution surface MONTHLY MAINTENANCE Check that the device does not pre...

Page 12: ...damped Dust on PCB board Stabilize the load and scale Dry the scale Clean PCB board Reading is not zero without load Unstable system power Load cell stressed too much or too long Longer warm up time...

Page 13: ...y compartment trapdoor and remove it b Change the 3 batteries with the correct polarity c Close the trapdoor and carry out a test a a b 11 User Manual NAUSICAA WEIGHING SYSTEM Distributed by NAUSICAA...

Page 14: ...Article 2 The warranty entitles the free labor and the free replacement of defective parts Article 3 The original out going shipping costs of the device and all associated costs are the responsibility...

Page 15: ...device under warranty has been modified without the approval of NAUSICAA M dical S A S Article 6 During the repair of any defective equipment no loan will be made Article 7 All warranty claims must b...

Page 16: ...Phone 33 0 466 717 184 Fax 33 0 466 532 305 Mail export nausicaa medical com Web www nausicaa medical eu Distributed by NAUSICAA Medical S A S 12 all e du Piot ZA P le Actif 30660 GALLARGUES LE MONTU...