background image

 

 

 

W410 DISPLAY UNIT 

 

MANUAL 

 

Models: W410/D, W410XB/D, W410XW/D, W410XL/D 

PREFACE  

Thank you for purchasing the Navis anemometer. This manual provides information for the best performance and safe application of 
the anemometer display unit. This manual does not cover the anemometer sensors for which the manuals will come separately.  
Read this manual carefully before starting the installation. Keep this manual after installation for future reference. 
 

INTRODUCTION 

W410 models are long-range display units which receive data from NAVIS wind sensors, display various wind data and use internal 
and external alarms for warnings about excess wind speed. Smartphone compatibility (W410XB/D, W410XL/D models) allows real-time 
wind data monitoring on smartphones or tablets. Wi-Fi compatibility (W410XW/D, W410XL/D models) allows real-time wind data 
monitoring on 

“Navis Live Data” web interface. 4-20 mA output (W410XB/D, W410XW/D and W410XL/D models) allows connection to 

external devices. Various wind data can be stored on SD card (W410XL/D model). 
 

 

 

 

 

 

 

 

 

 

 

 

 

1. Display 

 

 

 

 

 

 

 

 

 

2. Red and Yellow alarm lights 

 

 

 

 

 

 

 

 

 

3. Keys 

 

 

 

 

 

 

 

 

 

4. Relays signal lights 

 

 

 

 

 

   

 

 

 

5. Buzzer 

 

 

 

 

 

 

 

 

 

6. SMA antenna connector 

 

 

 

 

 

 

 

 

 

7. SD card insertion 

 

 

 

 

 

 Figure 1. (W410 display unit 

– front panel)

 

 
The W410 display is compatible with NAVIS sensors: WS 010-1 (wind speed sensor, standard range), WS 011-1 (wind speed sensor, 
extended range), WSD 010-1 (wind speed/direction sensor, standard range), WSD 011-1 (wind speed/direction sensor, extended 
range), WS 011-1-EX (wind speed sensor for explosive environments), WSD 011-1-EX (wind speed/direction sensor for explosive 
environments). 
 

MOUNTING  

Select the position where the signal reception is strong enough under all conditions. Use remote antenna if necessary.  
Display unit can be mounted onto the ferrous surface with four mounting magnets (optional accessories) or with mounting screws (not 
enclosed) to any flat surface. 

 

Mounting the display unit with screws:  
Unscrew all 4 plastic screws and remove the front panel. Note that the screws can be pulled out only at the correct angle. Place the 
rear panel of the display unit to the final mounting position and mark the position for the bores. Remove the casing and drill holes for 
the mounting screws. Place the rear panel of the display unit in position and tighten the mounting screws. Attach the front panel of the 
display unit with 4 plastic screws. 
 

ANTENNA CONNECTION 

Connect the enclosed antenna to the SMA connector on the display unit only when the power supply is switched OFF. 
 

OPERATION 

If the display unit is delivered as a set, with the sensor included, the correct sensor address is already set.  
Otherwise please set the correspondent sensor address first. Check the address settings procedure in the 

chapter “SETTINGS”. 

Turn the sensor ON by rotating the sensor cups (see sensor user manual). 
Fresh wind data are received every two seconds. If data are not received for more than 30 seconds, 

the “No data” notification appears 

on the display. 

 

 

Reviews: