NEC Group Internal Use Only

 

Express5800/A2040e/A1040e 
Configuration Guide

 

 

 

Introduction 

This document contains product and configuration information that will enable you to configure your system. The 
guide will ensure fast and proper configuration of your NEC Express5800 server. 
The available models depend on sales regions. For details, 

please contact your region’s sales representative. 

June. 2018 
Rev. 1.0 

NEC Corporation

 

Summary of Contents for Express5800/A1040e

Page 1: ...ns product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server The available models depend on sales regions For details please contact your region s sales representative June 2018 Rev 1 0 NEC Corporation ...

Page 2: ...Memory Capacity at Memory Rank Sparing 19 Memory Clock 20 Maximum Memory Capacity 20 4 Internal Disk Drives 21 4 1 RAID Configuration 21 4 2 Internal Drive Configuration 22 5 Optical Drive 24 6 PCI Card 24 6 1 PCI Hot Plug Kit 24 6 2 Network Interface Controller 24 6 3 External Storage Controller 28 7 Other Add in Components 30 7 1 Power Supply Unit 30 7 2 Redundant Fan Kit 32 7 3 Redundant Manage...

Page 3: ...mory 37 Internal Drive 43 Connection to RDX USB by Device Expansion Unit 46 Server Management 47 PCI Slot Available Slots and Installation Limitations 48 PCI Card Priority Order of Installation 53 RAS Feature Matrix per OS 55 Copyright Notice and Liability Disclaimer 58 REVISION HISTORY 59 ...

Page 4: ...atinum hot plug max 4 units AC100V 200V 10 50 60Hz 3Hz 863VA 846W 863VA 846W 863VA 846W 863VA 846W 863VA 846W 2827VA 2771W 2781VA 2725W 2655VA 2602W 2608VA 2556W 2543VA 2492W 2899VA 2841W 2853VA 2796W 2726VA 2672W 2680VA 2626W 2615VA 2563W 859VA 842W 859VA 842W 859VA 842W 859VA 842W 859VA 842W 2813VA 2757W 2767VA 2712W 2641VA 2589W 2595VA 2543W 2531VA 2480W 2885VA 2827W 2838VA 2782W 2713VA 2659W 2...

Page 5: ...842W 859VA 842W 859VA 842W 859VA 842W 859VA 842W 859VA 842W 2595VA 2543W 2531VA 2480W 2531VA 2480W 2251VA 2206W 2337VA 2290W 2337VA 2290W 2666VA 2613W 2602VA 2550W 2602VA 2550W 2323VA 2276W 2409VA 2360W 2409VA 2360W 9454KJ h 9226KJ h 9226KJ h 8236KJ h 8540KJ h 8540KJ h Operating 10 to 40 Non operating 10 to 55 Operating 10 to 40 Non operating 10 to 55 Operating 10 to 40 Non operating 10 to 55 Oper...

Page 6: ... 2641W 2569VA 2517W 2522VA 2471W 2457VA 2408W 2813VA 2757W 2766VA 2711W 2640VA 2588W 2594VA 2542W 2529VA 2478W 798VA 782W 798VA 782W 798VA 782W 798VA 782W 798VA 782W 2728VA 2673W 2681VA 2628W 2556VA 2505W 2509VA 2459W 2445VA 2396W 2799VA 2743W 2753VA 2698W 2627VA 2575W 2581VA 2529W 2516VA 2466W 9924KJ h 9760KJ h 9315KJ h 9151KJ h 8922KJ h Operating 10 to 35 Non operating 10 to 55 Operating 10 to 4...

Page 7: ...2W 798VA 782W 798VA 782W 798VA 782W 2509VA 2459W 2445VA 2396W 2445VA 2396W 2166VA 2122W 2252VA 2206W 2252VA 2206W 2581VA 2529W 2516VA 2466W 2516VA 2466W 2237VA 2192W 2323VA 2276W 2323VA 2276W 9151KJ h 8922KJ h 8922KJ h 7932KJ h 8236KJ h 8236KJ h Operating 10 to 40 Non operating 10 to 55 Operating 10 to 40 Non operating 10 to 55 Operating 10 to 40 Non operating 10 to 55 Operating 20 to 80 Non opera...

Page 8: ...y for A1040e B UID Unit ID Switch L BMC Reset Switch L1 only for for A1040e C Clear Switch M SYSTEM POWER LED D NMI Switch N UID Unit ID LED E BMC Ready LED O SYSTEM STATUS LED F BMC OFF Switch P USB Connector G Control Switch Q 2 5 inch Hard Drive Bay H SYSTEM AC POWER LED R Auxiliary Cooling Fan Module AFM I Control LED S Slide Tag J LAN Connector Maintenance LAN J1 only for A1040e ...

Page 9: ...nt LAN A1 only for A1040e E PCI Card Expansion Slot 2 B USB Connector F Power Supply Unit C SUV Cable Connector 1 G IOB ALARM LED D UID Unit ID LED H Rear Connector Module RCM 1 2x USB Connectors and 1x Serial Port and 1x VGA Connector are available through SUV Cable attachement to the server 2m length 2 For A1040e max 13 slots ...

Page 10: ...CONFIGURATION GUIDE NEC Express5800 A2040e A1040e NEC Corporation Rev 1 0 June 2018 10 Dimensions mm A2040e A1040e The above illustrations includes front bezel and slide rail mount kit ...

Page 11: ...UIDE NEC Express5800 A2040e A1040e NEC Corporation Rev 1 0 June 2018 11 Configuration Diagram A2040e Legend Standard components Minimum required components A1040e Legend Standard components Minimum required components ...

Page 12: ...lot 14 A2040e only PCI Express 3 0 x8 lane x8 socket Slot 15 PCI Express 3 0 x16 lane x16 socket Slot 16 PCI Express 3 0 x16 lane x16 socket NOTE For all PCI slots Low Profile 167 65mm in length For A2040e Slot 1 to 8 are available in case of 2CPU configuration Slot 1 to 12 are available in case of 3CPU configuration All slots Slot 1 to 16 are available in case of 4CPU configuration For A1040e Slo...

Page 13: ...ailable PCI Slots and Maximum No of Memory No of CPU Max No of DIMM Available PCI Slots 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 24 Y Y Y Y Y Y Y Y 3 36 Y Y Y Y Y Y Y Y Y Y Y Y 4 48 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 1 2 A1040e Product Name Description Part Number NEC Express5800 A1040e No processor no RAM no HDD no ODD no Power Supply Unit no OS NE3300 301F NOTE The base models must be ordered with ...

Page 14: ...e required software license as appropriate In case of using socket license based software please enable CPU core at the CPU socket on which the software is operating Software license is required for the socket with at least one enabled CPU core Depending on the OS the server may need to be rebooted to enable CPU cores Remarks to use COPT under Linux environment When using Fibre Channel Controller ...

Page 15: ... 5115 2 40 GHz 10C 20T 13 75MB TDP 85W NE3301 H109F CPU Board 4C Platinum 8156 Slot1 2 1 x Intel Xeon Processor Platinum 8156 3 60 GHz 4C 8T 16 50MB TDP 105W NE3301 H110F CPU Board 4C Gold 5122 Slot1 2 1 x Intel Xeon Processor Gold 5122 3 60 GHz 4C 8T 16 50MB TDP 105W NE3301 H111F CPU Board for Slot 3 and 4 for 3rd and 4th processor CPU Board 28C Platinum 8180M Slot3 4 CTO 1 x Intel Xeon Processor...

Page 16: ...consumption by adjusting voltage clock per CPU workload Power Saving Intel SpeedShift Technology Technology to decrease power consumption by adjusting CPU clock Performance Intel Turbo Boost Technology Technology to boost clock frequency Performance Intel Hyper Threading Technology Technology to use one core as two threads Virtualization Intel Virtualization Technology Technology to provide hardwa...

Page 17: ...B 64GB RDIMM 3DS 192GB 8GB RDIMM 384GB 16GB RDIMM 1152GB 768GB 32GB RDIMM 2688GB 2304GB 1920GB 1536GB 64GB RDIMM 3DS 192GB 8GB RDIMM 384GB 16GB RDIMM 768GB 32GB RDIMM Data Correction ECC SDDC ADDDC Notes RDIMM and LRDIMM cannot be mixed Need to order memory for sparing Need to order memory for mirroring 1 6 memory channels per CPU 2 All DIMMs have the same capacity Customized Configuration Service...

Page 18: ...M 2x64GB R 3DS QR CTO 2x 64GB Registered DIMM 3DS DDR4 2666 PC4 2666 ECC NOTE This is CTO categorized item lead time for delivery is longer than other regular items NE3302 H104F 256GB MEM 2x128GB R 3DS 8R CTO 2x 128GB Registered DIMM 3DS DDR4 2666 PC4 2666 ECC NOTE To be released in Sep 2018 This is CTO categorized item lead time for delivery is longer than other regular items In case of installin...

Page 19: ...NOTE Not preinstalled Need to order at least 1 set 4x DIMM Different Memory cannot be mixed in a server 1 spare rank available with 8GB 16GB RDIMM 1 or 2 spare ranks available with 32GB RDIMM 1 2 3 or 4 spare ranks available with 64GB RDIMM 3DS Logical Memory Capacity at Memory Rank Sparing The following table shows logical memory capacity at memory rank sparing showing the capacity per CPU No of ...

Page 20: ... maximum clock Please refer to Memory of Reference section for the details too CPU Memory No of DIMM per CPU Memory Clock 1 2V Xeon Platinum 8180M Platinum 8180 Platinum 8176M Platinum 8176 Platinum 8160 Platinum 8156 Gold 6150 Gold 6136 Gold 6144 Gold 5115 RDIMM 8 16 32GB Up to 12 2666 MHz RDIMM 3DS 64 128GB Up to 12 2666 MHz Xeon Gold 5122 RDIMM 8 16 32GB Up to 12 2400 MHz RDIMM 3DS 64 128GB Up ...

Page 21: ... RAID 50 RAID5 RAID0 6 8 Drive Capacity x No of Drive 2 Y RAID 60 RAID6 RAID0 6 8 Drive Capacity x No of Drive 4 Y NOTE Needs to order RAID Controller to configure internal drives For RAID Configuration same type of internal drives need to be ordered within one RAID group pack Multiple RAID group can be configured by one RAID Controller In case of RAID1 4 groups at maximum Different capacity rotat...

Page 22: ...port 4x 2connectors PCIe 3 0 x8 SAS 12Gb s NE3303 178 Flash Back up optional Flash Back up Unit LSI MegaRAID SAS 9362 8i 300mm Flash Back up Unit Cable attached NE3303 H101 Cable SAS Cable 1 x mini SAS to 1 x mini SAS x2 included HDD Cage 2 5 inch HDD Cage 8x 2 5 inch Drive Bay Hot Plug supported included Internal Drives Max 8 SAS HDD 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sec...

Page 23: ...Drive Bay Hot Plug supported included Internal Drives Max 8 SAS HDD 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 479A 600GB HDD 1x 600 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 481A 900GB HDD 1x 900 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 482A 1 2TB HDD 1x1 2TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483A 300GB HDD 1x 300 G...

Page 24: ...quired for PCI Card hot plug replace add for A2040e Product Name Description Part Number PCI Hot Plug Kit NE3415 H102 NOTE A1040e does not support PCI Hot Plug 6 2 Network Interface Controller Category Product Name Description Part Number 1GbE 1000 BASE T Adapter 2ch Broadcom BCM5718 PCIe 2 0 x4 Performance PCIe 2 0 x1 Low Profile NOTE PXE Boot by IPv6 not supported NE3304 151M 1000 BASE TAdapter ...

Page 25: ...R 1 x SFP Module for NE3304 149 NOTE This item is not built in configured at the delivery shipped separtely NE3304 129 QSFP Module 1 x QSFP Module for NE3304 159 NOTE This item is not built in configured at the delivery shipped separtely NE3304 161 NOTE Network Interface Controller not pre installed and this server does not have LAN interface port at the base module Needs to order at least 1 card ...

Page 26: ...ultiple cards Up to 2 ports per one team Up to 8 teams per one system NE3304 157 10GBASE T 2 ports in one card 2 ports among multiple cards Up to 2 ports per one team Up to 8 teams per one system NOTE Teaming with one port shared among multiple teams Not supported Network interface for teaming should be all the same Teaming of the port using iSCSI Not supported Linux Bonding Network Interface Oper...

Page 27: ...configuration See the table below for supported network interface and OS combinations Network Interface Operating System 1GbE NE3304 151M 152M 152L Windows Server 2016 VMware 10GbE 10GBASE SR NE3304 158 158L Windows Server 2016 VMware NE3304 159 VMWare 10GbE 10GBASE T NE3304 157 157L Windows Server 2016 VMware NOTE NIC Teaming Bonding features are not supported on iSCSI interfaces Redundant paths ...

Page 28: ...uring the RAID rebuilding process It is recommended to set RAID array configuration drives less than 8 in order to minimize the risk of becoming multiple hard drives failure 6 3 2 Fibre Channel SAS Controller Categor y Product Name Description Part Number Fibre Channel Fibre Channel Controller 16G 1ch Broadcom LightPulse LPe16000B M6 Host Bus Adapter 16Gb s Optical PCIe 3 0 x8 Low Profile NE3390 1...

Page 29: ...d When requiring to connect to Device 2 right side of the Unit in front view connector 2 of the left side from rear view please consult with NEC through the sales representative for the details before ordering As 2m cables are used to connect SAS Controller and LTO rack mount type the following remarks should be noted when using the LTO rack mount type LTO 1U N8160 95 100 Cannot be mounted on top ...

Page 30: ...2 2 3 4 2 3 4 1000W 1 2 2 3 4 3 4 3 4 Not Available 6136 8160 6144 1600W 1 1 2 2 2 3 4 2 3 4 1000W 1 2 2 3 4 3 4 3 4 Not Available 5122 8156 1600W 1 1 2 2 2 3 4 2 3 4 1000W 1 2 3 2 3 4 4 3 4 Not Available 5115 1600W 1 1 2 2 2 3 4 2 3 4 1000W 1 2 3 2 3 4 4 3 4 Not Available AC100V 8180M 8180 1600W 1 2 3 4 2 3 3 4 Not Available 4 4 Not Available Not Available 1000W 1 2 3 4 2 3 3 4 Not Available 4 4 ...

Page 31: ... 2N 1 N 1 When one Power Supply Unit fails the operation can continue 2 2N Configuring 2 power supply groups each consisting of 1 or 2 power supply unit When one group fails the operation can continue with another group In this case power supply is redundant between PSU 1 and PSU 2 or PSU 3 and 4 Please configure power supply path appropriately Hot plug supported Can replace Power Supply Unit with...

Page 32: ... Drive Encryption feature Supported OS Windows Server 2016 NE3315 H102 NOTE This is to be shipped only at the delivery of the server cannot be add on later When installed in the server cannot be removed later Need to enable TMP Support in BIOS Set up Menu to use this item Need to save recovery password for Windows BilLocker Drive Encription as the password is necessary to recover the data when rep...

Page 33: ...nsole Unit 1U 17 inch LCD US 83 keys Keyboard Optical mouse 1U height 4 pin USB B to 4 pin USB A cable 2 m PS 2 Y splitter cable 2m 15 pin mini D sub VGA cable 2 m BLACK N8143 105F 17inch LCD Console Drawer 1port 17 inch LCD US 103 keys Keyboard with 10 key Touch pad with 3 button 1U height 4 pin USB B to 4 pin USB A cable 1 8m Two PS 2 cable 1 8 m 15 pin mini D sub VGA cable 1 8 m N8143 108F Keyp...

Page 34: ...s up to 8 server There is one USB connector on the front side of the server For the rear side one VGA connector can be available by connectinig the cable to SUV cable connector Please refer to the Rack Mount Configuration Guide for the details 8 3 Server Management License The server integrates the Baseboard Management Controller to provide server management features Refer to Server Management sec...

Page 35: ...B NE3343 H101 NOTE This makes server depth longer as shown in the Dimensions For calculation LAN UTP without shield is regarded as φ5mm in diameter at average then 1x FC cable corresponds to 1x LAN cable 1x SAS cable corresponds to 2x LAN cables 1x SUV cable corresponds to 4x LAN cables and 1 x USB Cable corresponds to 1 x LAN cable Table for quick reference Model A2040e A1040e Max cable capacity ...

Page 36: ...JRE 8 9 For Windows terminal 32bit version J2SE Runtime Environment for JRE 8 64bit version for JRE 9 Client OS Windows Windows Vista SP2 Windows 7 Windows 8 1 Windows 10 Windows Server 2008 Windows Server 2008 R2 SP1 Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 with IPv6 Windows 7 Windows 8 1 Windows 10 Windows Server 2012 Windows Server 2012 R2 Windows Server 2016 Linux Red Hat...

Page 37: ...hen mixing different capacity of memory larger capacity memory is installed first Differenct capacity of DIMM cannot be mixed when using memory sparing or mirroring Cannot use both memory sparing and memory mirroring RDIMM and RDIMM 3DS cannot be mixed 5 sets 10x DIMM per CPU Board is not allowed to configure in order to avoid performance decrease risk due to unbalanced memory Different rules are ...

Page 38: ...h 24 or less DIMMs CPU1 DIMM1 2 CPU2 DIMM1 2 CPU3 DIMM1 2 CPU4 DIMM1 2 CPU1 DIMM4 5 CPU2 DIMM4 5 CPU3 DIMM4 5 CPU4 DIMM4 5 CPU1 DIMM3 6 CPU2 DIMM3 6 CPU3 DIMM3 6 CPU4 DIMM3 6 8 or more DIMM per CPU configuration 1CPUs with 7 or more DIMMs 2CPUs with 13 or more DIMMs 3CPUs with 19 or more DIMMs 4CPUs with 25 or more DIMMs CPU1 DIMM1 2 CPU2 DIMM1 2 CPU3 DIMM1 2 CPU4 DIMM1 2 CPU1 DIMM4 5 CPU2 DIMM4 5...

Page 39: ...IMM4 5 CPU3 DIMM3 6 CPU4 DIMM1 2 CPU4 DIMM4 5 CPU4 DIMM3 6 8 or more DIMM per CPU configuration 1CPUs with 7 or more DIMMs 2CPUs with 13 or more DIMMs 3CPUs with 19 or more DIMMs 4CPUs with 25 or more DIMMs CPU1 DIMM1 2 CPU1 DIMM4 5 CPU1 DIMM7 8 CPU1 DIMM10 11 CPU1 DIMM3 6 CPU1 DIMM9 12 CPU2 DIMM1 2 CPU2 DIMM4 5 CPU2 DIMM7 8 1 CPU2 DIMM10 11 CPU2 DIMM3 6 CPU2 DIMM9 12 CPU3 DIMM1 2 CPU3 DIMM4 5 CPU...

Page 40: ...3 DIMM7 8 10 11 CPU4 DIMM7 8 10 11 CPU1 DIMM3 9 6 12 CPU2 DIMM3 9 6 12 CPU3 DIMM3 9 6 12 CPU4 DIMM3 9 6 12 At 1 2 3CPU configuration please skip blank CPU in the installation order A2040e COPT Decentraliz ed For 32GB MEM for Memory Rank Sparing 4x8GB and 64GB MEM for Memory Rank Sparing 4x16GB Sparing is only supported by 8x DIMM or 12 x DIMM configuration Sparing with 4x DIMM is NOT supported CPU...

Page 41: ...less DIMMs CPU1 DIMM1 2 3 CPU2 DIMM1 2 3 CPU3 DIMM1 2 3 CPU4 DIMM1 2 3 CPU1 DIMM4 5 6 CPU2 DIMM4 5 6 CPU3 DIMM4 5 6 CPU4 DIMM4 5 6 8 or more DIMM per CPU configuration 1CPUs with 7 or more DIMMs 2CPUs with 13 or more DIMMs 3CPUs with 19 or more DIMMs 4CPUs with 25 or more DIMMs CPU1 DIMM1 2 3 CPU2 DIMM1 2 3 CPU3 DIMM1 2 3 CPU4 DIMM1 2 3 CPU1 DIMM4 5 6 CPU2 DIMM4 5 6 CPU3 DIMM4 5 6 CPU4 DIMM4 5 6 C...

Page 42: ...DIMM1 2 3 CPU3 DIMM4 5 6 CPU4 DIMM1 2 3 CPU4 DIMM4 5 6 8 or more DIMM per CPU configuration 1CPUs with 7 or more DIMMs 2CPUs with 13 or more DIMMs 3CPUs with 19 or more DIMMs 4CPUs with 25 or more DIMMs CPU1 DIMM1 2 3 CPU1 DIMM4 5 6 CPU1 DIMM7 8 9 CPU1 DIMM10 11 12 CPU2 DIMM1 2 3 CPU2 DIMM4 5 6 CPU2 DIMM7 8 9 CPU2 DIMM10 11 12 CPU3 DIMM1 2 3 CPU3 DIMM4 5 6 CPU3 DIMM7 8 9 CPU3 DIMM10 11 12 CPU4 DIM...

Page 43: ...in the BTO configuration Mixing HDDs with different rotation speed and mixing HDD and SSD is NOT supported in the BTO configuration Cannot mix the different drives within a RAID group pack When defining hot spare disk under mixed drive configuration need to set Dedicated Hot Spare per RAID group Global Hot Spare is not available Please refer to the following for further details With different inte...

Page 44: ...CONFIGURATION GUIDE NEC Express5800 A2040e A1040e NEC Corporation Rev 1 0 June 2018 44 ...

Page 45: ...D Configuration NE3303 178 or NE3303 177 4 2 1 4 2 2 up to 8 drives 1 RAID 0 Q ty 1 2 RAID 1 Q ty 2 3 8 RAID 1 if the number of drive is odd will set one spare drive NOTE Up to 4 RAID group pack per server Need to order same capacity rotation speed drives in one group disk array for RAID configuration at BTO configuration Initial settings of RAID Controller is Write Through without Flash Back up U...

Page 46: ...or USB3 0 is not available 2m cable is necessary to connect between Device Expansion Unit and USB connector on the rear side of the server Therefore please be aware of the following restrictions about the location of the Device Expansion Unit Device Expansion Unit N8141 69 1U 1 Can locate within 2U from the top or bottom of the server 2 Device 1 on the left side from the front right connecter 1 fr...

Page 47: ...ation only OS shutdown 1 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS ESMPRO SM required 1 Maintenance EXPRESSSCOPE Profile Key Backup restore BIOS BMC setup information Others Set automatic IP address via DNS DHCP LDAP Active Directory verification user control Clock synchronization of m...

Page 48: ...4 4 When installing RAID contoller NE3304 177 NE3304 178 with Flash Backup Unit up to 1 x External RAIC Controller with Flash Backup Unit can be installed to PCIe Slot 2 3 4 5 6 5 Not supporting PXE Boot with 2 x NE3304 159 i e enabling 2 x Option ROM 10GBASE Tadapter 2port Card Perf PCI Express 3 0 x4 For LAN connection 1 WOL Wake On LAN PXE Preboot eXecution Environment boot supported 2 PXE Preb...

Page 49: ...up Unit can be installed to PCIe Slot 2 3 4 5 6 5 Not supporting PXE Boot with 2 x NE3304 159 i e enabling 2 x Option ROM 10GBASE Tadapter 2port Card Perf PCI Express 3 0 x4 For LAN connection 1 WOL Wake On LAN PXE Preboot eXecution Environment boot supported 2 PXE Preboot eXecution Environment boot supported 10GBASE Adapter QSFP 4ch Card Perf PCI Express 3 0 x8 For LAN connection Need to separate...

Page 50: ...E3303 177 NE3303 H004 NE3303 184 NE3390 157A NE3390 158A Max 2 cards per CPU NE3304 151M NE3304 152M NE3304 158 NE3304 159 NE3304 157 1 Max number of slots depends on the number of CPU Max slot A2040e 1CPU 4slots 2CPU 8slots 3CPU 12slots 4CPU 16slots A1040e 1CPU 4slots 2CPU 8slots 3CPU 11slots 4CPU 13slots 10GBASE Tadapter 2port Max 7 cards per server Max of slots 1 16 13 1000BASE T Adapter 4port ...

Page 51: ...Matrix general RAID Controller 1GB RAID 0 1 5 6 External RAID Controller 2GB RAID 0 1 5 6 SAS Controller 12Gb s SAS Same as Available Slots Matrix general Max 2 cards per CPU Fibre Channel Controller 1port 16Gbps Optical Fibre Channel Controller 2port 16Gbps Optical Same as Available Slots Matrix general 1000BASE T Adapter 2port Same as Available Slots Matrix general 1000BASE T Adapter 4port Max 1...

Page 52: ... 157A NE3390 158A NE3304 151M Max 5 cards 2 Max 8 cards 2 2 2 Max 1 card 2 Max 1 card 2 NE3304 152M 2 2 Max 4 card 2 2 2 2 NE3304 158 2 2 2 Max 2 card 2 2 NE3304 159 2 2 Max 2 card 2 2 2 NE3304 157 2 2 2 2 2 2 16 16 13 15 16 16 In addition to the above please also follow Available Slots Matrix general and Installation Limitations due to I O Space 1 Max number of slots depends on the number of CPU ...

Page 53: ... 158 8 12 4 16 7 11 3 15 13 1 9 5 14 2 10 6 16 NE3390 158A 8 12 4 16 7 11 3 15 13 1 9 5 14 2 10 6 15 Low NE3390 157A 8 12 4 16 7 11 3 15 13 1 9 5 14 2 10 6 15 When another card is already installed in a slot the card will be installed to the slot with next priority Note PCI cards with higher priority as shown above high to low are to be installaled first The number in the list shown with shows the...

Page 54: ...ress 3 0 x8 Note PCI cards with higher priority as shown above high to low are to be installaled first The number in the list shown with shows the priority of the slots for each card to be installed shows the card cannot be 10GBASE Adapter QSFP 4ch Card Perf PCI Express 3 0 x8 For LAN connection Need to separately order QSFP Module NE3304 161 when necessary 10GBASE Tadapter 2port Card Perf PCI Exp...

Page 55: ... De allocation RHEL7 Y N 1 WS2016 N N ESXi6 5 N N Dynamic Memory Page De allocation Memory Page Offline RHEL7 Y N 1 WS2016 Y Y 2 ESXi6 5 Y Y PCIe Hot Add PCIe Hot Remove RHEL7 Y N WS2016 N N ESXi6 5 N N Static COPT Reboot Required COPT Model RHEL7 Y COPT N 4 WS2016 Y COPT N 5 ESXi6 5 Y COPT N Dynamic COPT Core Enabling COPT Model RHEL7 Y COPT N 1 WS2016 N N ESXi6 5 N N Dynamic COPT CORE Sparing CO...

Page 56: ...ress Based Memory Mirroring RHEL7 Y N 1 WS2016 N N ESXi6 5 N N Reliable Memory RHEL7 N N WS2016 N N ESXi6 5 Y Y MCA Recovery RHEL7 Y Y WS2016 Y Y ESXi6 5 Y Y Enhanced MCA Recovery Gen 2 BIOS MCA Recovery on Gen2 MCA added by E7v3 gen RHEL7 Y Y WS2016 Y Y ESXi6 5 Y Y PCIe Live Error Recovery RHEL7 Y Y 1 WS2016 N N ESXi6 5 N N Mission Critical I O Failover Windows WS2016 Y Y 6 ...

Page 57: ... the EXPRESSBUILDER With Windows Seamless Install the necessary modules are automatically installed 3 intentionally blanked 4 As an option if you install the necessary module acccording to the documents Machine Check Monitoring Service User s Guide Capacity Optimization COPT User s Guide for Linux core allocation among CPUs can be adjusted 5 As an option if you install the necessary module accordi...

Page 58: ...ntel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for techni...

Page 59: ...CONFIGURATION GUIDE NEC Express5800 A2040e A1040e NEC Corporation Rev 1 0 June 2018 59 Revision History Revision Date Description Rev 1 0 June 2018 Initial Release ...