background image

APPLICATION

XR luminaires are designed for use indoors, outdoors, wet locations, areas containing moisture, dirt, 

corrosion, vibration and rough usage.  The XR luminaire has been certified for use on marine vessels inside, 

outside, and in other severely wet saltwater environments. 

Certified to:   

UL 844, UL 1598, UL 1598A, and UL 8750;

 

 

 

CSA C22.2 No. 137, CSA C22.2 No. 250.0 and CSA C22.2 No. 250.13

   Hazardous 

Location 

Certication:

 

 

 

Class I, Division 2, Groups ABCD;

 

 

 

Class II, Division 2, Groups FG;

   Class 

III;

 

 

 

Class I, Zone 2, Group IIC;

   Zone 

22

   

Housing:  

 

Copper-free Cast Aluminium with Polycarbonate lens

Input Voltage:   

Based on luminaire suffix in table below: Suffix - AC: 120-277 VAC | Suffix - HV: 347-480 VAC  

Electrical Ratings: 

Connections:   

3 x 3/4” NPT Conduit | Black: Line | White: Neutral | Green: Ground

   

Optional:   Violet: 0-10V Dimming (+)  |  Grey: 0-10V Dimming (-)

  

 

 

For connections use wire rated to a minimum of 90°C.  Class 1 Wiring only.

 

 

 

All supply field wiring must be rated 300V minimum for luminaires with suffix AC, 

 

 

 

600V minimum for luminaires with suffix HV.

Ambient

Temperature Range:       Class I Division 2 | Class I Zone 2                   Class II Division 2 | Zone 22

    

XR8: -50°C to +75°C         T3C     

     All models -50°C to +50°C     T3C

                                                 

XR10: -50°C to +74°C      T3C

                                                 

XR15: -50°C to +74°C      T3C

                                                 

XR20: -50°C to +67°C      T3

Ingress Protection: 

IP66  | Suitable For Wet Locations. Marine Outside Type (Salt Water)

SURFACE/CEILING 

MOUNTING INSTALLATION

LUMINANCE

XR8 

XR10 

XR15 

XR20 

RATED VOLTAGE

[Volts]

RATED WATTAGE

[Watts]

INPUT

VOLTAGE

AC

HV

AC

HV

AC

HV

AC

HV

120-277
347-480
120-277
347-480
120-277
347-480
120-277
347-480

Flood: 47 Optic: 60
Flood: 49 Optic: 64
Flood: 55 Optic: 75
Flood: 58 Optic: 77

Flood: 84 Optic: 103
Flood: 91 Optic: 107

Flood: 141 Optic: 156
Flood: 148 Optic: 160

FREQUENCY

[Hz]

50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60

TM

Nemalux

I N D U S T R I A L

XR-HAZ

rev. A-13

E477829

1-14

www.nemalux.com  |   sales@nemalux.com  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

E477829

*PENDING*

*PENDING*

Summary of Contents for XR-HAZ

Page 1: ...ed to a minimum of 90 C Class 1 Wiring only All supply field wiring must be rated 300V minimum for luminaires with suffix AC 600V minimum for luminaires with suffix HV Ambient Temperature Range Class...

Page 2: ...xterior lens surface with damp cloth only SURFACE CEILING MOUNT INSTALLATION Refer to alternate instructions if using Conduit Hook Wall Pole or Yoke Mount Step 2 Step 3A Step 3B TM Nemalux I N D U S T...

Page 3: ...assification of the area of installation Connect Violet and Gray driver lead wires to 0 10VDC control wiring LED Drivers will source a combined maximum of 200 A for control needs 0 10V Controller must...

Page 4: ...ot to be used WIRING DIAGRAM PS 1 GROUND Factory BLACK LINE WHITE NEUTRAL GREEN GROUND VIOLET DIM GREY DIM BLACK WHITE GREEN VIOLET GREY TM Nemalux I N D U S T R I A L XR HAZ rev A 13 4 14 www nemalux...

Page 5: ...stallation instructions provided with luminaire STEP 4 in XR Installation Instructions from the Surface Ceiling Mount installation provided with Luminaire SET SCREW This XR PM kit is intended for use...

Page 6: ...to mount main body Torque to 1 7 N m 15 in lbs STEP 6 Mount luminaire assembly to desired location using 4x 1 4 20 OR M6 Screws or Bolts Not Provided STEP 7 Resume installation instructions provided w...

Page 7: ...sses on the XR cheek plates should register inside of the large circular holes on the XR high vibration yoke mount arms Rotate luminaire to aim in the desired direction and fasten in place using 2x M6...

Page 8: ...nt yoke assembly to luminaire using 4x M6 Socket Head Cap Screws and Washers Provided Torque fasteners to 5 Nm 45 in lbs STEP 5 Mount luminaire assembly to desired location using 4x 1 4 20 OR M6 Screw...

Page 9: ...ly and provide protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrit...

Page 10: ...ate steel cable or chain through the outer band of the unit and fastening a closed loop Secondary safety hardware must be rated for a minimum of 110lbs Install remaining loop of secondary safety chain...

Page 11: ...dy near AC input Secure the surge protector and driver lead wires together as close to the origin of the driver lead wires as possible using the provided zip tie STEP 4 Wire according to wiring instru...

Page 12: ...s from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case PS 1 GROUND Factory BLACK WHITE WH...

Page 13: ...provided zip tie STEP 4 Wire according to wiring instructions on Page 14 14 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close XR Wiring Cover Ensure the retention cable is...

Page 14: ...conductor and White leads from LED Drivers 3 Connect Green wire from surge protector to splice or terminal connected to Grounding branch circuit conductor and green lead from luminaire case TM Nemalux...

Reviews: