background image

Neomatica. LLC. Tracker ADM50 GLONASS / GPS. Rev.1.2 dated 03.10.2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ADM50

Page 1: ...Neomatica LLC Tracker ADM50 GLONASS GPS Rev 1 2 dated 03 10 2018 1 ...

Page 2: ...cker should be carried out by qualified specialists to ensure its proper functioning For successful application of the tracker it is necessary to familiarize with the working principle of the entire monitoring system and understand the purpose of all its components separately Therefore it is strongly recommended to familiarize with the basics of the functioning of the global navigation satellite s...

Page 3: ...s 6 4 2 Blue LED GSM module status 7 4 3 Red LED battery charge process status 7 4 4 Determining the battery charge level 7 5 Operating Modes 7 5 1 Beacon Mode 8 5 2 Tracker Mode 9 6 Functioning of the SOS Button 10 7 Low Battery Warning 11 8 Updating the terminal software 11 8 1 Updating the terminal software via USB 11 8 2 Updating the terminal software via GPRS 12 8 3 Updating the terminal soft...

Page 4: ...nctions in the automatic mode The SOS alarm button is used to activate a mechanism for sending an SMS message and sending an information packet with the alarm flag to the server After switching on the tracker receives information from the satellites of the GLONASS GPS system determines its location speed time and establishes a connection to the server After establishing the connection tracker tran...

Page 5: ...perating temperature in battery discharge mode 20 60 C Operating temperature in battery charging mode 0 45 C Maximum current consuming in standby mode to 1 A Charger voltage 5 V Dimensions 89х56х25mm Weight not more than 125 g 3 Turning on and off 3 1 Turning on and off with the power button To turn on the tracker press and hold the power button at least for three seconds When the three LEDs begin...

Page 6: ...en so switching on the tracker and the function of determining the battery charge level are still available By default the lock is disabled The configuration performs locally using the configurator via the USB interface or remotely by sending commands via GPRS or SMS POFF X X 0 Power button unlocked X 1 Power button locked To disable the tracker using the button you must disable the Power button l...

Page 7: ...ED flashes once a second charging LED lights permanently charging completed LED flashes more often than once a second the charging process is completed abnormally It is possible if the temperature of the device has exceeded the allowed limits or the device s charging time has been exceeded LED does not lit there is no external power It is possible if the USB cable is not connected or there is no c...

Page 8: ...ll the necessary actions were performed This time allows to wait for an incoming SMS containing the command maximum activity time the time after which the ADM50 will go to sleep even if it didn t not perform all the necessary actions for example determine the coordinates or send data to the server sleep time after successful activity the time for which the ADM50 will be in sleep state if all the n...

Page 9: ...etermining the coordinates has lower accuracy than navigation using GLONASS GPS systems but significantly saves battery power Auto Z 3 selecting the source of coordinates is in automatic mode The priority system is GLONASS GPS In the case if signal strength from satellites is low and the coordinates are not valid the location determines by GSM base stations BWAKEUP The command carries out an extra...

Page 10: ...ep Static mode 0 off 1 on If in the Deep Statics mode the GSM module stay enabled then regardless of the GLONASS GPS module status the tracker will send packets with the last valid coordinate to the server Y the state of the GLONASS GPS module in the Deep Static mode 0 off 1 on The parameter impacts on the navigation data availability speed when leaving the Deep Statics mode 6 Functioning of the S...

Page 11: ...arning Upon reaching the set voltage level on the battery an SMS message with the text device_name battery low will be sent to authorized by command EventListAdd phone numbers The activation of the function and the setting of the critical voltage level is performed using the command BATALARM X Y X 0 alert function disabled X 1 function enabled Y critical battery voltage level mV 8 Updating the ter...

Page 12: ...he server until connection attempts are over The upgrading process will start after the terminal receives UPDATE command via one of the possible channels USB GPRS SMS After having received the UPDATE command the terminal connects to the upgrade server and uploads the relevant firmware After a successful upgrade the terminal passes to the standard operation mode with the access point and server add...

Page 13: ...of transportation storage installation and handling The warranty does not cover a terminal with mechanical damages and defects cracks and chips dents signs of impacts etc caused by consumer as a result of handling storage and transportation rules violation When there are signs of oxidation or other proofs of liquid penetration in the device housing a terminal without housing a terminal with signs ...

Page 14: ... performed according to national and local norms and requirements 13 Scope of supply Name Quantity Terminal ADM50 1 Power Supply Charger 1 Datasheet 1 Manufacturer Neomatica LLC 24а Malkova office 7 Perm 614087 Russia Phone 7 342 2 111 500 ext 42 E mail sales neomatica com Web site http neomatica com ...

Page 15: ... of the memory location to store the number Optional parameter Authorize the phone number from which the SMS was received and write it to the memory cell Y The command is needed only to create a list of numbers for controlling the terminal via SMS 3 PHONES X Example PHONES 1234 PHONES 0 1 2 3 Example PHONES 0 1 79876543210 2 3 X password the default is 0 Request a list of authorized phone numbers ...

Page 16: ...conds after power on 7 PIN0 Example PIN0 1234 PIN0 X Example PIN0 1234 X PIN code Setting PIN code for SIM card 8 PIN1 Example PIN1 1234 PIN1 X Example PIN1 1234 X PIN code Setting PIN code for SIM chip 9 SETGPRS0 X Y Z Example GPRS0 APN X user Y pass Z Example X access point by default X internet beeline ru Y login by default Y beeline Set GPRS parameters for SIM card The command without paramete...

Page 17: ...M card and SIM chip 12 SETHOST0 X Y Example SETHOST0 134 236 21 2 123 00 HOST0 X Y Example HOST0 134 236 21 2 12300 X IP address use commas instead of dots Y server port Setting IP address and server port which the terminal is connected to for data transmission The command without parameters restores to the current server address and port 13 DN0 X Y Example SETHOST0 www test ru 1000 HOST0 X Y Exam...

Page 18: ...g the duration of activity and sleep states in Beacon mode BTIME 30 180 600 300 BTIME 30 180 600 300 Y maximum activity time in seconds Z sleep time after successful activity A sleep time after error in seconds 17 BWAKEUP BWAKEUP OK Extraordinary awakening the tracker in the Beacon mode 18 WHERE Request for a link to Yandex Maps with the last valid coordinates Answer is in text SMS message 19 PERI...

Page 19: ...mmand Changing the parameters of the TRACK command can lead to incorrect work of the tracker 21 TSTIME X Example TSTIME 300 TSTIME X Example TSTIME 300 X the time through which the deep statics mode activates in seconds Setting the time through which the transition to the Deep Statics mode will occur when there is no movement 22 TSMODE X Y Example TSMODE 1 1 TSMODE X Y Example TSMODE 1 1 X status ...

Page 20: ...low battery alarm 27 EventListAdd X Example EventListAdd 79876543210 Number was added to event list Example Number was added to event list X adding phone number in format 7xxxxxxxxxx Add a phone number to the list for sending alarm SMS List is storing no more than 4 phone numbers 28 EventListClear Event list was cleared Erasing all numbers from the list of phone numbers for sending alarm SMS 29 Ev...

Page 21: ...0 X request text Sending a USSD request Note it is necessary to enter space between the command name and its parameter or the command name and its parameters Parameters of commands are separated by comma without spaces except for the DN0 X Y command where between the parameters X and Y it is necessary to enter a colon ...

Page 22: ...ed on using the power button 1 1 2 2 No connection to the server 4 3 8 4 Sign of low battery voltage 16 5 Sign of invalidity of coordinates 32 6 Coordinates were fixed within absence of movement 64 7 External power of the terminal is disconnected 128 8 Button SOS is pressed 256 9 512 10 1024 11 2048 12 4096 13 8192 14 Coordinates are determined using GSM base stations 16384 15 32768 ...

Reviews: