Summary of Contents for HP Fire Service

Page 1: ...UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC H P F I R E S E R V I C E T U R B I N E I N S TA L L AT I O N A N D M A I N T E N A N C E G U I D E HP Fire Service Turbine Installation and Maintenance G...

Page 2: ...HP Fire Service Turbine Installation and Maintenance Guide ARB UTILITY MANAGEMENT SYSTEMS WATER GAS ELECTRIC...

Page 3: ...ntains the trade secrets and confidential information of Neptune Technology Group Inc which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part in any for...

Page 4: ...CONTENTS OVERVIEW Contacting Technical Support 1 1 INSTALLATION INSTRUCTIONS Installation Instructions 2 1 Recommended Installation 2 1 Before Operation 2 2 MAINTENANCE Maintenance Instructions 3 1 Tu...

Page 5: ...iv HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...

Page 6: ...ine that serves both fire and domestic use where flow rates are moderate to high In order to achieve maximum performance in actual service it is essential that these installation and maintenance instr...

Page 7: ...1 2 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...

Page 8: ...eptune meters with a strainer a minimum of two 2 to four 4 pipe diameters of straight run pipe can include components that are fully open in their normal operating position is required upstream and do...

Page 9: ...3 Slowly open inlet side gate valve to pressurize meter 4 Close air bleed screw clockwise when air is completely vented and no spitting occurs 5 Slowly open outlet side gate valve until downstream li...

Page 10: ...e cover bolts from the turbine 3 Remove cover and turbine measuring element from maincase 4 Install factory calibrated UME into maincase 5 Replace cover bolts 6 Tighten cover bolts 7 Follow steps 2 th...

Page 11: ...pproximately one percent change in registration The full range of the calibration vane is 180 STRAINER For maximum efficiency determine length of time it takes for baskets to become approximately one...

Page 12: ...HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE 3 3 NOTES...

Page 13: ...3 4 HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE NOTES...

Page 14: ...allassee AL 36078 USA Tel 800 645 1892 Fax 334 283 7299 Neptune Technology Group Canada Ltd 7275 West Credit Avenue Mississauga Ontario L5N 5M9 Canada Tel 905 858 4211 Fax 905 858 0428 Neptune Technol...