Use the AC power cords supplied with the product. 

If you use other AC power cords, they should have 

a wire gauge of at least 22 and a 230VAC 5A rating. 

Be sure to use three-prong cords and connect them 

to sockets with good earth grounds.

To connect input power:

1. Connect the ground stud near the bottom middle 

of the rear panel to a good earth ground. Usually 

this will be the same as the equipment rack ground.

2. Connect the AC power cords  to the power supplies 

and plug them into independent power sources.

3. Push the “1” side of the power supplies’ switches 

to activate power. The LEDs on the power supplies 

illuminate to indicate that power is active.

4. If you power up only a single supply, an alarm 

tone sounds. Press the red power supply alarm 

reset button just to the right of the power supplies 

to turn off the alarm sound. 

With DC models of the product, you must supply 

your own DC power cables. They should have a wire 

gauge of at least 16 and a 72VDC 4A rating. Always 

connect the earth grounds first, and keep the earth 

grounds connected whenever you are working on 

the device. When disconnecting the device from DC 

power, remove the earth ground connections last.

Connect to the Network and Tools

Tap the links you want to monitor (using external 

fiber or copper taps) and plug the outputs of the taps 

into any Director xStream ports that have SFP+ or 

SFP modules installed. You can also plug in switch 

Span ports that you want to monitor.

Plug tools into any Director xStream ports that have 

SFP+ or SFP modules installed.

Quick Install Guide 

Director xStream Pro™ 

Network Controller Switch 

Unpacking and Inspection

Carefully unpack Director xStream Pro

TM

 and retain 

materials for later use. Check the packing slip 

and parts list against parts received. If any part is 

missing or damaged, contact Net Optics Customer 

Service. (Note: SFP+ and SFP modules are 

ordered and shipped separately.)

Install SFP+ and SFP modules

Install SFP+ and SFP transceiver modules as 

desired in the SFP+ cages in the front of the 

chassis. The 8 ProPorts support only 10G SFP+ 

modules, while the 16 standard ports support 10G 

SFP+ and 1G SFP modules. For each module, 

remove the temporary plug from the SFP+ cage and 

insert the module until it clicks into place. Unused 

ports do not need to be populated with transceiver 

modules. 

Rack Mount the Chassis

Director xStream Pro is designed for mounting in a 

19-inch rack, occupying two rack units of height. 

To mount the Director xStream Pro device:

1. Expand the mounting rails to fit the depth of your 

rack.

2. Attach the mounting rails to the font and rear pillars 

of the rack using the supplied screws. The tabs 

that Director xStream Pro will sit on should be 

located toward the bottom.

3. Slide the Director xStream Pro chassis into the 

rack so it rests on the rail tabs.

4. Make sure the rack is properly grounded.

Connect Power

Director xStream Pro’s two redundant power 

supplies can be found at the rear of the unit on the 

right side. Either power supply can power the unit 

by itself, or you can connect both power supplies for 

high availability. If you use both supplies, be sure to 

connect them to independent power sources.

Power LED

16 SFP+ Standard Ports (10G or 1G)

8 SFP+ ProPorts (10G only, filtering, load balancoing, DPI)

© 2010 by Net Optics, Inc. Net Optics® is a registered trademark of Net Optics, Inc. Director xStream Pro

TM

 is a trademark   

  of Net Optics, Inc. 

800-0166-001 Rev C PUBDIRXPQ 12/10 

Management

ProPush

GPS

COM A

COM B

0

1  

0

1  

0

SERIAL

NUMBER

XXXXXX

Ground Stud

Management Port

GPS   Console Port (COM A)

Redundant Hot-swappable

Power Supplies

ProPush Port

Power Supply Alarm Reset Button