background image

NT-1200

 

 

 

Quick Setup Guide 

 

This is a plug and play model if you use a US keyboard. If you use other type of keyboard, plug the 
USB cable on your device , setup keyboard language before you use it. (refer to below Keyboard 
Language Type) after that the scanner can start to work.

 

 

          

 

 

          

 

 
 

If you want to do other configurations please refer to below programming barcodes.  

 

Barcode Programming  

 

Netum barcode scanners are factory programmed for common terminal and communications 
settings. If you need to change these settings, programming is accomplished by scanning the bar 
codes in this guide. An asterisk (*) next to an option indicates the default setting. 
 
 

Firmware Version 

 Read below command barcode to check scanner firmware version.

 

 

                                                           

                             

                                                                               000A0 
                                                                   

Firmware Version

 

 
Please advise the scanner model number and firmware version when you have any inquiry about 
the scanner. 

 
 
 

Summary of Contents for NT-1200

Page 1: ...efer to below programming barcodes Barcode Programming Netum barcode scanners are factory programmed for common terminal and communications settings If you need to change these settings programming is accomplished by scanning the bar codes in this guide An asterisk next to an option indicates the default setting Firmware Version Read below command barcode to check scanner firmware version 000A0 Fi...

Page 2: ...u use French Keyboard scan below barcode of French keyboard then scanner will upload barcodes according to France keyboard layout American Keyboard is set by default if you use a US keyboard you can skip this step American Keyboard Portugal Keyboard French Keyboard Spanish Keyboard Germany Keyboard Turkey Q Keyboard Italy Keyboard ...

Page 3: ...tinuous mode scanner performs continuous work Reading success or reading time over a single reading time will end the reading More than the specified time will automatically trigger the next reading 013304 Continuous Scanning Terminator configuration The scanner provides a shortcut for setting the terminating character suffix to CR or CRLF and enabling it by scanning the appropriate barcode below ...

Page 4: ...eep Tone OFF Default Configuration If you want to cancel all the configuration that you have done to the scanner Scan below barcodes to the restore factory 000B0 Factory Default Common Function Barcodes EAN 8 00371 00370 Enable EAN 8 Disable EAN 8 ...

Page 5: ...o form a new one In the examples below the part surrounded by blue dotted line is an EAN 8 barcode while the part circled by red dotted line is add on code The default mode opens Disable Add on Code Users can take Add On Code Setting for reference EAN 13 00361 00360 Enable EAN 13 Disable EAN 13 Transmit Check Digit EAN 13 is 13 digits in length with the last one as its check digit used to verify t...

Page 6: ...rt surrounded by blue line is an EAN 8 barcode while the part circled by red line is add on code The default mode opens Disable Add on Code Users can take Add On Code Setting for reference Codabar 00851 00850 Enable Codabar Disable Codabar Code 11 01261 01260 Enable Code 11 Disable Code 11 Code 39 00221 00220 Enable Code 39 Disable Code 39 ...

Page 7: ...able Code 93 Disable Code 93 Code128 00691 00690 Enable Code 128 Disable Code 128 GS1 DataBar Limited RSS Limited 01771 01770 Enable RSS Limited Disable RSS Limited GS1 DataBar Ominidirectional RSS Ominidirectional 01671 01670 Enable RSS Ominidirectional Disable RSS Ominidirectional ...

Page 8: ...smit UPC A Check Digit Users can choose to send it or not 00421 Transmit UPC A Check Digit 00420 Transmit UPC A Check Digit Add On Code A UPC A barcode can be augmented with a two digit or five digit add on code to form a new one In the examples below the part surrounded by blue line is a UPC A barcode while the part circled by red line is add on code Users can take Add On Code Setting for referen...

Page 9: ...351 00350 Enable UPC E Disable UPC E Add On Code Setting In the example below the part surrounded by blue line is a UPC A barcode while the part circled by red line is add on code Users can take Add On Code Setting for reference Interleaved 2 of 5 00961 00960 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ...

Page 10: ...nable Industrial 2 of 5 Disable Industrial 2 of 5 Standard 2 of 5 01871 01870 Enable Standard 2 of 5 Disable Standard 2 of 5 Matrix 2 of 5 01461 01460 Enable Matrix 2 of 5 Disable Matrix 2 of 5 MSI 01151 01150 Enable MSI Disable MSI ...

Page 11: ...sable Plessey Add On Code Setting Users can scan the code below to open or close the setting of UPC EAN JAN 00551 00552 Enable 2 Digit Add On Code Enable 5 Digit Add On Code 00553 00550 Enable2 5 Digit Add On Code Disable Digit Add On Code ...

Page 12: ...process of scanning you can use Code ID prefix to recognize the barcode type Please read Appendix A for the reference of the Code ID corresponding barcode type No Code ID default setting 01400 Disable Code ID 01401 Enable Code ID prefix 01402 Enable Code ID suffix ...

Page 13: ...2242 Exit Custom Prefix and Suffix Custom Prefix Step 1 Scan code of 02240 add prefix Note This step will clear all previous setting Maximum you can add 32 character 02240 Step 2 Scan relevant barcode of the prefix that you want to add from Appendix B For example If you want to add MG as the prefix Step1 Scan 02240 ...

Page 14: ... code of 02241 add suffix 02241 Note This step will clear all previous setting Maximum you can add 32 characters Step 2 Scan relevant barcode of the suffix that you want to add from Appendix B You will get the suffix through above two steps after you scan barcodes 8 Clear all suffix Scan clear all suffix 02220 then all previous prefix configuration will be cleared 02200 ...

Page 15: ...DE 128 3 C 03 EAN 8 4 D 04 EAN 13 5 E 05 UPC A 6 F 06 UPC E 7 I 09 CODE 93 8 J 0A GS1 Omnidirectional 9 K 0B GS1 Limited 10 M 0D CODE 39 11 N 0E Interleaved 2 of 5 12 O 0F Industrial 2 of 5 13 P 10 Standard 2 of 5 14 Q 11 Matrix 2 of 5 15 S 13 MSI 16 T 14 Plessey 17 U 15 CODE 11 18 V 16 Codebar ...

Page 16: ...X 03 1004 EOT 04 1005 ENQ 05 1006 ACK 06 1007 BEL 07 1008 Backspace 08 1009 HT 09 1010 LF 0A 1011 VT 0B 1012 FF 0C 1013 CR 0D 1014 SO 0E 1015 SI 0F 1016 DEL 10 1017 DC1 11 1018 DC2 12 1019 DC3 13 1020 DC4 14 1021 NAK 15 1022 SYN 16 1023 ETB 17 1024 CAN 18 ...

Page 17: ... 1026 SUB 1A 1027 ESC 1B 1028 FS 1C 1029 GS 1D 1030 RS 1E 1031 US 1F 1032 Space 20 1033 21 1034 22 1035 23 1036 24 1037 25 1038 26 1039 27 1040 28 1041 29 1042 2A 1043 2B 1044 2C 1045 2D 1046 2E 1047 2F 1048 0 30 ...

Page 18: ...50 2 32 1051 3 33 1052 4 34 1053 5 35 1054 6 36 1055 7 37 1056 8 38 1057 9 39 1058 3A 1059 3B 1060 3C 1061 3D 1062 3E 1063 3F 1064 40 1065 A 41 1066 B 42 1067 C 43 1068 D 44 1069 E 45 1070 F 46 1071 G 47 1072 H 48 ...

Page 19: ... J 4A 1075 K 4B 1076 L 4C 1077 M 4D 1078 N 4E 1079 O 4F 1080 P 50 1081 Q 51 1082 R 52 1083 S 53 1084 T 54 1085 U 55 1086 V 56 1087 W 57 1088 X 58 1089 Y 59 1090 Z 5A 1091 5B 1092 5C 1093 5D 1094 5E 1095 _ 5F 1096 60 ...

Page 20: ...2 1099 c 63 1100 d 64 1101 e 65 1102 f 66 1103 g 67 1104 h 68 1105 i 69 1106 j 6A 107 k 6B 1108 l 6C 1109 m 6D 1110 n 6E 1111 o 6F 1112 p 70 1113 q 71 1114 r 72 1115 s 73 1116 t 74 1117 u 75 1118 v 76 1119 w 77 1120 x 78 ...

Page 21: ...1121 y 79 1122 z 7A 1123 7B 1124 7C 1125 7D 1126 7E 1127 Delete 7F ...