Update-Backup-Analysis

Updating firmware 
Saving, loading configuration
Saving, evaluating Recording
Updating LON Modules
FST-2XT and FST-2XTs Recovery
Updating LON Modules

Troubleshooting

Short instructions

Summary of Contents for FST-2XT MRL

Page 1: ...L Update Backup Analysis Updating firmware Saving loading configuration Saving evaluating Recording Updating LON Modules FST 2XT and FST 2XTs Recovery Updating LON Modules Troubleshooting Short instructions ...

Page 2: ...2XT V2 000 xxx Doc No hb_Update Backup Analysis FST 2XT FST 2XTs_2020 09_en Copyright NEW LIFT Steuerungsbau GmbH 2020 This manual is protected by copyright All rights including those of copying of reproduction of translation and of modification in whole or in part are reserved by the publisher No part of this description may be reproduced in any form or copied with an electronic replication syste...

Page 3: ...m the USB stick 11 5 Recording 12 5 1 FST Recording 12 5 1 1 Saving FST recordings on the USB stick 12 5 2 GST XT Recording 12 5 2 1 Enable GST XT Recording 13 5 2 2 Checking GST XT Recording Status 13 5 2 3 Saving GST XT recordings on the USB stick 14 5 2 4 Relevant menu items 14 5 2 5 Others 14 5 3 Evaluating recordings via EleVision Light 15 5 3 1 Downloading EleVision Light software 15 5 3 2 V...

Page 4: ...ckup Analysis FST 2XT FST 2XTs 8 Error list 28 8 1 Save error list on the USB stick 28 8 2 Visualising the error list 28 9 1 Control system failure 28 9 2 The FST application does not start 29 9 3 Error messages 30 ...

Page 5: ... follow this symbol in the specified order Warning notice This symbol is located in front of safety relevant information Information notice This symbol is located in front of relevant information 1 2 Notation Notation Meaning Bold Designations of menus options buttons check boxes input and display fields display areas navigation areas software functions Keyboard commands Italics Designations of fo...

Page 6: ...MRL Manual FST Installation Commissioning Manual GST XT Manual LCS Manual RIO Manual SAM Manual UCM A3 Manual These and other up to date manuals can be found in the download area of our website at https www newlift de downloads 311 html 1 4 How to contact us If after referring to this manual you still require assistance our service line is there for you Phone 49 89 898 66 110 E mail service newlif...

Page 7: ...cable is required for the following programs FST Editor Elevision Light Lon Modul Center Technical data 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Connections A and B SUB D socket to SUB D socket Pinning Pin Conductor color connection A Conductor color connection B Assignment A B 1 black orange 1 4 2 brown red 2 3 3 red brown 3 2 4 orange black 4 1 5 yellow yellow 5 5 6 not assigned 7 green blue 7 8 8 bl...

Page 8: ...rvice line in advance There are two ways to obtain the firmware update 1 via E mail 2 via Link NEW LIFT Cloud Save the firmware update file that you received in the newly created update folder on the USB stick At https www newlift de downloads 311 html you will find the following relevant files for download Information on version differences FST 2XTchanges customer EN pdf This document hb_Update B...

Page 9: ... is only displayed if the USB stick is plugged in Select option Upd f USBStick Select YES to start the update After a few seconds the FST 2XT update screen appears The update may take up to 4 minutes Following a successful update the message UPDATE COMPLETE appears briefly on the screen If the update could not be completed successfully e g if the FST controller restarts immediately after briefly d...

Page 10: ...ntroller call up MAIN MENU GST Menu Configuration Update GST f USB Select YES to start the update The message GST WAITING TO RESET appears briefly on the screen The entire update process of the GST firmware takes approximately 50 seconds 25 seconds for the update and 25 seconds for the automatic restart of the GST XT During the update process the LEDs of the GST XT illuminate continuously in seque...

Page 11: ...onfig USBStick Select YES The configuration data is stored on the USB stick in automatically created subdirectories The message Config TRANSFER OK appears briefly on the screen For unique identification beginning with version V2 000 0102 the file is given a unique file name that is made up of the NEW LIFT factory number installation ID and the lift factory number provided this information has been...

Page 12: ... daily If no recordings are present for the day of the query the message Rec not available Exit Menu OK appears Selec NO to remain in the menu Set the date setting to the relevant date Select YES to save the recording for the selected date to the USB stick Unplug the USB stick from port X41 of the FST 2XT The message USBStick REMOVED appears briefly on the screen 5 2 GST XT Recording The integrate...

Page 13: ...atic recording Switch the power supply of the GST XT OFF and ON again 5 2 2 Checking GST XT Recording Status This menu item can be used to check whether the recording of the GST XT is currently being performed In the menu of the FST controller call up MAIN MENU GST MENUE Status Window The status of the recording can be read out in the first line of the display REC ON GST XT Recording is running RE...

Page 14: ...ly on the screen 5 2 4 Relevant menu items Menu item Description Setting range GST Re corder Recorder RESTART Start GST recording Certain internal events are recorded with date and time This recording is stored on a standard SD Card option The recording will not start if a SD Card is not inserted YES NO GST Re corder Recorder STOP Stop the GST recording YES NO GST Re corder Recorder CONTINUE Conti...

Page 15: ...en the website https www newlift de downloads 311 html Select sub item PC software Depending on Windows requirements download software for Windows XP LMS EleVision Light or Windows 7 LMS EleVision Light Win 7 Extract the software and execute the installation file ElevisionLightVx_xx exe The program automatically adds a start icon to the screen ...

Page 16: ... FST 2XTs 5 3 2 Visualising recordings with EleVision Light Start the software The program automatically loads a demo project the first time it is started On every subsequent program start the program loads the last created project Demo project ...

Page 17: ...roject type Recording Press the FST Configfile Recordingbutton Navigate to the stored recording file and double click to open it Confirm the next two dialogs with OK While the recording file is loading the recording converter automatically creates the files in the bin and txt formats If necessary change the folder structure at this point and exit the window with OK ...

Page 18: ...ording window opens Start playback of the recording with Play The program simulates the recorded events At the same time you can follow the individual event steps in the Detail Grid Recording window select individual events and call up information To exit Elevision Light click on Quit in the menu bar The program automatically closes all windows The project as well as all corresponding text and bin...

Page 19: ...BStick This menu item is only displayed if the USB stick is plugged in Select YES The system automatically performs an update The message Updated Moduls x appears on the screen whereby x corresponds to the number of updated modules If the USB does not contain any valid data the message Update not successful no valid file found appears on the screen In this case contact the New LIFT service line or...

Page 20: ...omatically adds a start icon to the screen 6 3 Updating with Lon Module Center software Connect PC and FST controller port X9 with null modem cable via the serial interface Start the software Bridge the service pins of the used module with a metal object e g screwdriver The software detects the module type and automatically opens an editor window with information on the module in the example here ...

Page 21: ...used module Drag the selected file down into the Lon Module Type window using drag and drop Confirm the query Do you really want to perform the program update with Yes to start the update A progress window appears on the screen Wait until the progress window closes and the screen with the message Module successfully pro grammed appears ...

Page 22: ...ystem is still starting The screen shows the NEW LIFT logo and the FST lettering Up to software version 2 000 0132 the debug jumper has to be set FST start screen 7 1 FST 2XT Recovery Software The software FST 2XT_recover_V2 000 013x zip must be requested from our service line in advance There are two ways to obtain the software 1 via E mail 2 via Link NEW LIFT Cloud Save the received zip file FST...

Page 23: ...lect the option Extract all The window extract ZIP compressed folder opens Reduce the suggested drive path to the drive name for example drive I and click to the extract button After unpacking the directory structure must look as follows The directory structure after unpacking ...

Page 24: ...the PC plug on the X41 port of the FST Switch off the FST controller with the control fuse F4 For software versions up to V2 000 0132 Connect any jumper e g from J90 on X7 Connect the debug jumper between PIN1 and PIN3 on X7 upper row first and second pin from right FST 2XT debug jumper plugged in FST 2XTs debug jumper plugged in ...

Page 25: ...ck Recovery finished When the message remove USB Stick appears remove the USB stick The FST restarts automatically Restart Wait until the FST 2XT s has completely booted Switch off the FST 2XT s by means of control fuse F4 Remove the Debug jumper if necessary and plug it to its original position Switch on the FST 2XT s by means of control fuse F4 Wait until the controller has completely booted Rec...

Page 26: ...starts again after the reboot Remove the USB stick after the end of the Recovery process Can Recovery and the firmware update be saved on the same USB stick Yes However during the update of the firmware the following points must be observed Do not plug the USB stick before the complete start up of the FST After a successful update immediately remove the USB stick 7 4 Program sequence Overview ...

Page 27: ...FST 2XT and FST 2XTs Recovery Update Backup Analysis FST 2XT FST 2XTs 27 7 5 Program structure ...

Page 28: ...red on the USB stick as error_list txt The message Error LIST TRANSFER OK appears briefly on the screen Unplug the USB stick from port X41 of the FST 2XT The message USBStick REMOVED appears briefly on the screen 8 2 Visualising the error list Open the error list txt file on the PC with the help of Windows WordPad or another editor program 9 Troubleshooting With software versions beginning with V2...

Page 29: ...ug jumper plugged in FST 2XTs debug jumper plugged in Switch control system back on The control system starts after approx 5 seconds Serial interface X9 may be limited in function after the jumper is set In this case please inform the NEW LIFT service line 9 2 The FST application does not start The update might not be completely carried out when installing an FST update Run the application FST Rec...

Page 30: ...RD TRANSFER ERR Recording performed incom pletely or incorrectly Recording was interrupted Repeat recording procedure DIR NOT FOUND Capitalisation of file name not correct Folder not present Rename folder on USB stick Create folder on USB stick UNZIP FAILED The file with extension tar was already extracted into folder update Copy file FST 2XT_update_ V2 000 xxxx tar to the USB stick again and repe...