background image

NEXCOM International Co., Ltd.

 

NEXCOM International Co., Ltd.

 

Published January 2019

 

www.nexcom.com

 

Intelligent Platform & Services Business Unit  

Kiosk Panel PC 
KPPC 1514B/1814B/2114B 

User Manual

 

Summary of Contents for KPPC 1514B

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published January 2019 www nexcom com Intelligent Platform Services Business Unit Kiosk Panel PC KPPC 1514B 1814B 2114B User Manual ...

Page 2: ...uction KPPC1514B 1814B 2114B Series 1 Specifications 2 Knowing Your KPPCSeries 4 RearTop 4 RearBottom 5 Rear 6 Mechanical Dimensions 7 KPPC 1514B 7 KPPC 1814B 8 KPPC 2114B 9 Chapter 2 Jumpers and Connectors Before You Begin 10 Precautions 10 Jumper Settings 11 Locations of the Jumpers and Connectors 12 LAN Ports LEDDescription 13 Jumpers 14 Clear RTCRAM 14 COM1 Ring 5V 12V Selection 14 LVDS Panel ...

Page 3: ...or 25 Front Panel Audio Connector 26 Chapter 3 System Setup Removing the Top Cover 27 Installing SO DIMM Memory Modules 29 Installing a SATA StorageDrive 30 Installing LGA1151 35W CPU 33 Installing Expansion Cards 36 Chapter 4 BIOS Setup About BIOS Setup 38 When to Configure the BIOS 38 Default Configuration 39 Entering Setup 39 Legends 39 BIOS Setup Utility 41 Main 41 Advanced 42 Chipset 50 Secur...

Page 4: ...s a trademark of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCCcompliance statement for ClassA devices and describes how to keep the system CEcompliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Clas...

Page 5: ...directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which NEXCOM are renowned The model selection criteria will be based on ...

Page 6: ...r 1 Any claimed defect products that have been repaired or modified by persons who have not been authorized by NEXCOM or products which have been subjected to misuse abuse accident improper installation or usage not in accordance with the product instruction NEXCOM assumes no liability as a consequence of such events under the term of this warranty One example is the replacement of Tablet s or Han...

Page 7: ... CPU and DIMM If the key parts are included please be noted clearly within the return form NEXCOM takes no responsibility for the parts which are not listed in the return form 4 Customers hold the responsibility to ensure that the packing of defective products is durable enough to be resistant against further damage due to the transportation damage caused by transportation is treated as Out of War...

Page 8: ... for main IC chipsets such asthe N B S B Super IO LAN Sound Memory and so on c 3rd party Device Fee products replacement for CPU DIMM HDD Chassis and UPS 2 Out of Warranty product will have a three months warranty for the fixed issues If the product failed with different problem within 3 months they will still incur the service charge of Out of Warranty 3 Out of Warranty products will not be repai...

Page 9: ...damage the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Readall instructionscarefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the sys...

Page 10: ...an the voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opene...

Page 11: ...ormation of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information ab...

Page 12: ...td Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw NexCOBOT Taiwan Co Ltd 13F No 916 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw GreenBase Technology Corp 13F No 922 Chung Cheng...

Page 13: ... Huiyinmingzun PlazaBldg 1 No 609 Yunlin East Rd Shanghai 200062 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Floor 5 Building C ZhenHan Industrial Zone GanKeng Community Buji Street LongGang District ShenZhen 518112 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang nexcom com tw www nexcom cn NEXCOM United Syst...

Page 14: ... Spring Flat Washer Long Fei P3x6L 3 5 5061700832X00 HDD Bracket 2 HDD Bracket Power Adapter Thermal Pad Screws Dual HDD Bracket SATA Cable Flat Head Screw Round Head Screw KPPC1514B 1814B 2114B Series Optional Assy HDD Kit P N 10IK0061404X0 14 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual Item Part Number Description Qty 1 5061700985X00 Dual HDD ...

Page 15: ...l Rights Reserved KPPC1514B 1814B 2114B User Manual Item Description Qty 1 Panel Mounting Clips x12 P N 88YK0212100X0 12 Panel Mounting Clips x12 KPPC1514B 1814B 2114B Series Optional HDD Kit Package P N 10IK0061404X0 Item Description Qty 1 2x 2 5 HDD Bracket Kit for IKS614B with SATACable A000 P N 10IK0061404X0 10 ...

Page 16: ...ower adapter w o power cord P N 7400084003X00 KPPC2114B P N 10YK0211400X0 21 5 LED backlight touch panel PC with Intel CPU FCLGA1151 35W w 2 x HDMI 2 x GbE LAN 4 x USB 3 0 2 x serial port 1 x Line out 1 x Mic in 12V 84W power adapter w o power cord P N 7400084003X00 Optional Intel Pentium G4400TE 3M Cache 2 4 GHz 2C 2T 35W P N 71IX02GTM4X00 Intel Pentium G4600TE 3M Cache 2 4 GHz 2C 4T 35W P N TBD ...

Page 17: ...x1080 P Cap multi touch display KPPC 2114B Support rich I O 2 x GbELAN 2 x COM 5 x USBetc Mounting support Panel Wall Stand VESA KPPC1514B 1814B 2114B Metal housing with robust aluminum IP65 compliant front bezel for harsh environment Fanless design KPPC1514B 1814B 2114B Series Overview 1 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 18: ...3000 LCDcolor 16 7M Viewing angle 89 U 89 D 89 L 89 R Backlight LED Touchscreen enTpointsP Cap projected capacitive touch Light transmission 86 Interface USB Anti scratch surface 7H hardness System CPU 6th generation Intel CoreTM formerly codenamed Skylake with socket supporting FCLGA1151 35W processors Memory Dual DDR4 2133MHz SO DIMM up to 16GB for KPPC1514B 1814B 2114B non ECC un buffered Graph...

Page 19: ...to 113 F 0 C to 45 C Storage temperature 4 F to 140 F 20 C to 60 C Operating humidity 10 90 relative humidity non condensing Dimension 417 80 W x 312 80 H x 66 25 D mm KPPC 1514B 490 80 W x 320 60 H x 65 15 D mm KPPC 1814B 562 40 W x 382 40 H x 65 35 D mm KPPC 2114B Weight 7 44kg KPPC 1514B 8 0kg KPPC1814B 9 9kg KPPC2114B OS Support List indWows10 IoT 64 bit Certifications EMC Safety CE FCCClassA ...

Page 20: ...witch Pressto power on or power off the panel PC USB 2 0 Used to connect USB2 0 1 1 devices HDD LED Indicates the hard drive activity of the system Power Switch USB2 0 HDD LED 4 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 21: ... 0 devices LAN Ports Dual Gigabit LAN port to connect the system to a local area network Line out Used to connect a headphone or a speaker Mic in Used to connect an external microphone COM1 and COM2 Serial ports to connect with compatible serial devices 12V DCInput COM 1 HDMI LAN Mic in COM 2 Line out USB3 0 5 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B Use...

Page 22: ...unting Hole M4 VESA Mounting Hole M4 VESA Mounting Hole M4 VESA Mounting Hole VESA Mounting Holes Theseare the mounting holes for VESAmount 100x100mm 6 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 23: ...UTLINE 6 2 66 3 26 8 36 260 78 9 103 5 103 5 29 5 401 3 89 5 100 158 9 M4 0 7 10 9 35 5 395 9 MOUNTING LINE 150 150 100 296 20 1 10 9 249 290 9 MOUNTING LINE 59 5 CUTOUTSIZET 3 0mm MAX KPPC1514B 7 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 24: ...ll Rights Reserved KPPC1514B 1814B 2114B User Manual 490 8 OUTLINE 232 2 VA 320 6 OUTLINE 6 5 65 2 25 7 39 6 260 115 4 475 4 2 5 89 5 100 195 4 10 2 55 2 M4 0 7 470 4 MOUNTINGLINE 167 5 167 5 100 305 2 20 1 10 2 249 300 2 MOUNTING LINE 91 9 91 9 45 7 44 5 CUTOUTSIZET 2 5mm MAX KPPC1814B ...

Page 25: ...E 6 7 65 35 25 85 42 09 260 151 2 362 MOUNTING LINE 103 5 103 5 10 2 65 547 2 5 109 4 7 100 231 2 10 2 91 542 MOUNTINGLINE 167 5 167 5 100 367 40 1 5 249 56 1 5 CUTOUTSIZET 2 5mm MAX M4 0 7 9 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 26: ...r is off Ground yourself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have lessstatic electricitythan dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges o...

Page 27: ... is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin Jumpers Pins1 and 2 are Short 11 Copyright 2019 NEXCOM International Co Ltd All Rights R...

Page 28: ...EATX_PWR2CHA_FAN1CPU_FAN1 DDR4 DIMM_A1 64bit 260 pin module DDR4 DIMM_B1 64bit 260 pin module I NV LJ2 LJ1 LJ3 COM2 DIO COM1_VSET COM1 BOTTOM EDP LVDS DP1 or HDMI1 DP2 or HDMI2 SATA_PWR ALC 887 RT3607CE BIOS_P Intel H110 Super I O PCIEX1_1 MINICARD1 MINICARD2 CH7511 LGA1151 LINE OUT MIC IN AMP_CON AAFP BATTERY_H LED_ 5V LED_ 5VSUS 128Mb BIOS 12 Copyright 2019 NEXCOM International Co Ltd All Rights...

Page 29: ...No link Off 10 Mbps network link Orange Linked Orange 100 Mbps network link Flashing Data activity Green 1 Gbps network link ACT LINK SPEED LAN Ports LED Description 13 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual Connector type RJ45port with LEDs ...

Page 30: ...rt Clear CMOS Pin Status Settings 1 2 Short 12V 3 4 Short 5V 5 6 Short Ring COM1 Ring 5V 12V Selection Connector type 2x3 6 pin header Connector location COM1_VSET 3 3 1 1 2Short Default 1 2 3Short 1 2Short 3 4Short 5 6Short Default 2 1 6 5 2 1 6 5 2 1 6 5 14 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 31: ...onnector location LJ1 3 3 1 1 2Short 1 2Short Default 1 2 3Short Default 2 3Short 1 3 1 15 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 3 Inverter Voltage Select Connector type 1x3 3 pin header Connector location LJ2 Pin Status Settings 1 2 Short DC Voltage Control 2 3 Short PWM Control ...

Page 32: ...Settings 1 2 Short 12V 2 3 Short 5V Chassis Intrusion Jumper Connector type 1x4 4 pin header Connector location CHASSIS Pin Status Settings 1 2 Open Enables the chassisintrusion detection feature 3 4 Short Disablesthe chassisintrusion detection feature 1 3 4Short Default 16 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 4 ...

Page 33: ...nnector location SATA_PWR Pin Definition Pin Definition 1 5V 2 GND 3 GND 4 12V Audio Amplifier Connector Connector type 1x4 4 pin header Connector location AMP_CON Pin Definition Pin Definition 1 ROUTP 2 ROUTN 3 LOUTN 4 LOUTP 4 1 1 17 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 4 ...

Page 34: ... CHA_FAN1 CPUFanConnector Connector type 1x4 4 pin header Connector location CPU_FAN1 Pin Definition Pin Definition 1 PWM 2 SENSE 3 VCC 4 GND Pin Definition Pin Definition 1 PWM 2 SENSE 3 VCC 4 GND 4 1 4 1 18 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 35: ...GND 26 LVDS0_CLK 27 LVDS0_CLK 28 GND 29 GND 30 GND 31 SPC1 32 INV_ENABKL 33 VCON 34 LVDS1_CLK 35 LVDS1_CLK 36 BLVCC 37 BLVCC 38 BLVCC 39 NC 40 SPD1 Pin Definition Pin Definition 1 NC 2 GND 3 eDP_TXN3_C 4 eDP_TXP3_C 5 GND 6 eDP_TXN2_C 7 eDP_TXP2_C 8 GND 9 eDP_TXN1_C 10 eDP_TXP1_C 11 GND 12 eDP_TXN0_C 13 eDP_TXP0_C 14 GND 15 eDP_AUXP_C 16 eDP_AUXN_C 17 GND 18 V_PANEL 19 V_PANEL 20 V_PANEL 21 V_PANEL...

Page 36: ..._I 3 4 DIO_I 4 5 DIO_O 1 6 DIO_O 2 7 DIO_O 3 8 DIO_O 4 9 5V 10 GND System Panel Connector Connector type 2x5 10 pin header Connector location F_PANEL Pin Definition Pin Definition 1 HDD_LED 2 PWR_LED 3 HDD_LED 4 PWR_LED 5 GND 6 PWRBTN 7 RSTCON _PANEL 8 GND 9 NC 10 NA 10 9 20 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 2 1 ...

Page 37: ... RSATA_TXP1 3 RSATA_TXN1 4 GND 5 RSATA_RXN1 6 RSATA_RXP1 7 GND 7 1 Serial ATA6 0Gb s Connector 2 Connector type Standard Serial ATA7P 1 27mm SATA M 180 Connector location SATA6G_2 Pin Definition Pin Definition 1 GND 2 RSATA_TXP2 3 RSATA_TXN2 4 GND 5 RSATA_RXN2 6 RSATA_RXP2 7 GND 7 21 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 1 ...

Page 38: ... type 2x5 10 pin header Connector location USB56andUSB78 2 1 22 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 10 9 USB56 Pin Definition Pin Definition 1 5V 2 GND 3 S_USB_PN 4 GND 5 S_USB_PP 6 S_USB_PP 7 GND 8 S_USB_PN 9 GND 10 5V USB78 Pin Definition Pin Definition 1 5V 2 GND 3 S_USB_PN 4 GND 5 S_USB_PP 6 S_USB_PP 7 GND 8 S_USB_PN 9 GND 10 5V ...

Page 39: ..._P Pin Definition Pin Definition 1 3V_SPI 2 GND 3 S_SPI_CS1 Q 4 S_SPI_CLK_2Q 5 S_SPI_MISO_2Q 6 S_SPI_MOSI_2Q 7 NC 8 NC Battery Connector Connector type 1x2 2 pin header Connector location BATTERY_H Pin Definition 1 BAT 2 GND 1 23 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 2 ...

Page 40: ...M International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 9 10 Serial Port Connector COM1 Connector type 2x5 10 pin header Connector location COM1 RS 232 Pin Definition Pin Definition 1 DCD 2 RXD1 3 TXD 4 DTR1 5 GND 6 DSR1 7 RTS1 8 CTS1 9 RI1_F_VCC 10 NC RS 422 and RS 485 Only COM1 supports RS 422 and RS 485 Pin Definition Pin Definition 1 422TXD 485DATA 2 422RXD 3 422TXD 485DAT...

Page 41: ...on Pin Definition 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI1_F_VCC 10 NC 4 pin DC In Power Connector Connector type 2x2 4 pin header Connector location EATX_PWR2 Pin Definition Pin Definition 1 GND 2 GND 3 DC_IN 4 DC_IN 1 25 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 2 3 4 ...

Page 42: ...on Pin Definition 1 PORT1 L 2 AGND 3 PORT1 R 4 NC 5 PORT2 R 6 SENSE1_RETUR 7 SENSE_SEND 8 9 PORT2 L 10 SENSE2_RETUR Legacy AC 97 Compliant Pin Definition Pin Definition Pin Definition 1 MIC2 2 AGND 3 MICPWR 4 NC 5 Line out_R 6 NC 7 NC 8 9 Line out_L 10 NC 10 9 26 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual 2 1 ...

Page 43: ...tom of the system chassis U TI O 27 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual U TI O C C A A U T I O N N Prior to removing the top cover make sure the unit s power is off and disconnected from the power sourcesto prevent electric shock or system damage ...

Page 44: ... Setup 2 t h e R s e c m r e o w v e s on the left and right sides of the system chassisthen remove the chassis cover 28 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 45: ...slot on the board SO DIMMSlots 29 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual t2h eInmseortduleinto the slot at an approximately 30degree angle Pushthe module down until the clips on both sides of the slot lock into position ...

Page 46: ... Drive 1 Fixthe brackets to the screw holes on the sides of the storagedrive u2r nTtothe back of the drive and secureit with screws 50311F0111X00 x 4 30 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 47: ...other ends of the cables to the connectors on the storage drive 4 The image below marks the location of the mounting post used to position the storage drive bracket to the system Fix the bracket to this mounting post 31 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 48: ...Chapter 3 System Setup 5e thSecburracketwith screws 32 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 49: ...ketand removethe protective cap CPUSocket ProtectiveCap 2 Unlock the socket by pushing the load lever down moving it sideways until it is released from the retention tab then lift the load lever up 33 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 50: ...its edges and avoid touching the pins The CPUwill fit in only one orientation and can easily be inserted without exerting any force C C A A U U T T I I O O N N 4 Close the load plate and then hook the load lever under the retention tab Do not force the CPUinto the socket Forcing the CPUinto the socket may bend the pins and damage the CPU C C A A U U T T I I O O N N 34 Copyright 2019 NEXCOM Interna...

Page 51: ...aced on the CPU C C A A U U T T I I O O N N Please install the thermal pad and make sure the adhesive film on the thermal pad is removed before placing it on the heat sink ThermalPad 35 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 52: ...d half size mini PCIe modules 1 Before installing the modules remove the I O cover by opening the cable ties and loosening the 3 screwson the bottom of the system HalfSizeMiniPCIe FullSizeMiniPCIe 36 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 53: ... down and secure it with mounting screw FullSizeMiniPCIe MountingPoint HalfSizeMiniPCIe MountingPoint i3n stAafltlienrgthe modules place the I O cover back to its original location and tighten the 3 screws to secureit then close the cable ties 37 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 54: ...on the systemisconfigured with the valuesfound in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Passwordprotection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all t...

Page 55: ...s initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screenwill display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Pressthe key to enterSetup Legends Key Function Moves the highlight left or right to select a menu Moves the highlight up or down between sub menu or fields Exits the ...

Page 56: ... and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press 40 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual ...

Page 57: ...Megatrends Inc BIOS Information R1 6 EHB0AM16 03 31 2017 Set the Date Use Tab to switch between Dateelements BIOS Vendor American Megatrends Compliancy UEFI 2 4 PI 1 3 System Date Sat 01 28 2017 System Time 00 10 20 Access Level Administrator SelectScreen Select Item Enter Select ChangeOpt F1 GeneralHelp F2 PreviousValues F3 OptimizedDefaults F4 Save Exit ESC Exit System Date The date format is da...

Page 58: ...figure the CPU settings Advanced 42 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc CPU Configuration Enabled for Windows XP and Linux OS optimized for Intel R Core TM i7 6700 CPU 3 40GHz CPU Signature 506E3 Microcode Patch A6 Max ...

Page 59: ...4 Save Exit ESC Exit Advanced 43 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc USB Configuration Enables Legacy USB support AUTO option disables legacy 1 Keyboard support if no USB devices are connected DISABLE option will keep U...

Page 60: ... 11 0 0 1194 Normal Mode Full Sku Firmware Consumer SKU Advanced Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Me FW Image Re Flash Disabled Local FW Update Enabled Enable Disable Me FW Image Re Flash function SelectScreen SelectItem Enter Select ChangeOpt F1 GeneralHelp F2 PreviousValues F3 OptimizedDefaults F4 Save Exit ES...

Page 61: ...stem SelectScreen SelectItem Enter Select ChangeOpt F1 GeneralHelp F2 PreviousValues F3 OptimizedDefaults F4 Save Exit ESC Exit Active Serial Port 1 Use This Device Enables or disablesthe serial port Possible Configures the base addressfor the serial port Mode Configures the serial port mode to RS232 RS422or RS485 Advanced 45 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B...

Page 62: ...yright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Serial Port 2 Configuration Enable or Disable this Logical Device Use This Device Enabled Logical Device Settings Current IO 2F8h IRQ 3 Possible Use Automatic Settings WARNING Disabling SIO Logical Devices may have unwanted side effects PROCEED WITH CAUTION SelectScreen SelectItem Enter Select Change...

Page 63: ... KPPC1514B 1814B 2114B User Manual Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Smart FanConfiguration Smart Fan Configuration System Temperature CPU Temperature PECI 40 c 100 c Chassis Fan 1 Speed CPU Fan Speed N A N A VCORE 12V 5V 3VSB 3 3V VBAT 0 992 V 11 904V 5 100 V 3 392 V 3 392 V 3 120 V SelectScreen Select Item Ente...

Page 64: ...he temperature setting Fan PWM 1 to Fan PWM 4 For Chassis1 Fan Configures the amount of fan PWNfor Smart FanIVMode Tolerance of Temperature For Chassis1 Fan Configures the tolerance of target temperature Critical Temperature For Chassis1 Fan Configures the time that FanOut requires for reducing its value by onestep Critical Temp Tolerance For Chassis1 Fan Configures the tolerance of critical tempe...

Page 65: ...ake system from S5 Enables or disablessystem wake up from S5 Fixed Time Dynamic Time System will wake on the hr min sec specified System will wake on the current time increase minute s Advanced Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Power Management Fixed Time System will wake on thehr min sec Power Mode Power Saving ...

Page 66: ...geOpt F1 GeneralHelp F2 PreviousValues F3 OptimizedDefaults F4 Save Exit ESC Exit System Agent SA Configuration Enters the System Agent SA Configuration submenu PCH IO Configuration Enters the PCH IOConfiguration submenu Chipset This section gives you functions to configure the system based on the specific features of the chipset The chipset manages bus speeds and access to system memory resources...

Page 67: ...em Enter Select ChangeOpt F1 GeneralHelp F2 PreviousValues F3 OptimizedDefaults F4 Save Exit ESC Exit System Agent Bridge Name Skylake Maximum Value of TOLUD Dynamic assignmentwould Memory Configuration Memory Frequency Total Memory DIMM 0 DIMM 1 2133 MHz 16384 MB 16384 MB Not Present adjust TOLUD automatically based on largest MMIO length of installed graphic controller Max TOLUD Max Link Speed D...

Page 68: ...Security Boot Save Exit 52 Copyright 2019 NEXCOM International Co Ltd All Rights Reserved KPPC1514B 1814B 2114B User Manual Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Password Description Set Administrator Password If ONLY the Administrator s password is set then this only limits access to Setup and is only asked for when...

Page 69: ...r A dialog box will appear Confirm by selecting Yes Main Advanced Chipset Security Boot Save Exit Version 2 17 1255 Copyright C 2017 American Megatrends Inc Aptio Setup Utility Copyright C 2017 American Megatrends Inc Save Changes and Reset Discard Changes and Reset Restore Defaults Reset the system after saving the changes SelectScreen SelectItem Enter Select ChangeOpt F1 GeneralHelp F2 PreviousV...