background image

NEXCOM International Co., Ltd.

NEXCOM International Co., Ltd.

Published July 2016

www.nexcom.com

Network

 

and

 

Communication

 

Solutions

Network Security Appliance 
NSA 5160

User Manual

Summary of Contents for NI 121F

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published July 2016 www nexcom com Network and Communication Solutions Network Security Appliance NSA 5160 User Manual ...

Page 2: ...roduction Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NSA 5160 3 Front Panel 3 Rear Panel 4 Chapter 2 Jumpers and Connectors Before You Begin 5 Precautions 5 Jumper Settings 6 Locations of the Jumpers and Connectors 7 Jumpers 8 RTC Clear 8 ME Firmware Update 8 BIOS Recovery Swap 9 TPM Select Pin Header 9 Console CTS Strap Pin Header 10 BMC Strap 10 Console UART Controller Stra...

Page 3: ...Removing the Chassis Cover 19 Installing a SATA DOM 20 Installing DIMM Memory Modules 23 Installing a 2 5 SATA Hard Drive 24 Installing a LAN Module 28 Chapter 4 Bios Setup About BIOS Setup 30 When to Configure the BIOS 30 Default Configuration 31 Entering Setup 31 Legends 31 BIOS Setup Utility 33 Main 33 Advanced 34 Intel RC Setup 44 Server Mgmt 55 Security 59 Boot 60 Save Exit 61 ...

Page 4: ...EXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digital dev...

Page 5: ... Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force in to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry...

Page 6: ...ective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warranty...

Page 7: ...nd power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection ...

Page 8: ...e the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system...

Page 9: ...e voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened onl...

Page 10: ...rsion application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth 3 CompactFlash Turn off the unit s power before inserting or removing a CompactFlash storage card Convention...

Page 11: ...920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 Shiba M...

Page 12: ...italia it NEXCOM Shanghai Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200333 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Room 209 Floor 2 East No 2 Science Technology industrial park of privately owned enterprises Xili Nanshan Dist Shenzhen 518055 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email st...

Page 13: ...70 x 240mm w China RoHS Symbol 1 4 6012200053X00 PE Zipper Bag 3 100 x 70mm w China RoHS Symbol 1 5 6023309081X00 Cable EDI 232091081804 RS COM Port DB9 Female to RJ45 8P8C L 1800mm 1 6 50311F0102X00 H Round Head Screw Long Fei P6 32T x 1 4 SW7 0 8 W Spring Flat Washer P6 32T x 1 4 SW7 x 0 8 NI 4 7 603ATA0052X00 SATA Cable ST MD 6104042 SATA 7P 180D Lock to 7P 90D Lock L 260mm 1 8 5060900301X00 NS...

Page 14: ...er ports with 2 bypass segment multi mode by PCIe x8 interface with PKG NI 140F Intel I350 module 4 fiber ports with PCIe x8 interface with PKG NI 180F Intel I350 module 8 fiber ports with PCIe x8 interface with PKG NI 142C Intel I350 module 4 copper ports with 2 bypass segment by PCIe x8 interface with PKG NI 180C Intel I350 module 8 copper ports by PCIe x8 interface with PKG NI 184C Intel I350 m...

Page 15: ...s multi mode None All Slot NI 140F 10SK000NI02X0 i350AM4x1 PCIe x8 4 SFP None None All Slot NI 180F 10S10180F01X0 i350AM4x2 PCIe x8 8 SFP None None All Slot NI 142C 10SK000NI03X0 i350AM4x1 PCIe x8 4 Copper 2 bypass None All Slot NI 180C 10S10180C01X0 i350AM4x2 PCIe x8 8 Copper None None All Slot NI 184C 10S10184C01X0 i350AM4x2 PCIe x8 8 Copper 4 bypass None All Slot NI 142F 10S10142F01X0 i350AM4x1...

Page 16: ...60 User Manual Chapter 1 Product Introduction Chapter 1 Product Introduction Key Features 1U rackmount network platform Intel Xeon processor D 1500 product family Support DDR4 2133 ECC REG up to 128GB Overview Onboard 8G LAN Copper 2 x 10G SFP Support up to two LAN modules ...

Page 17: ...tel XL710 Copper Fiber ports Support 10 100 1000 10G link speed I O Interface Front Power status HDD status LAN status Bypass status LEDs 2x USB 2 0 ports 1x RJ45 type console port 2x SFP ports 8x Copper LAN ports 2x LAN modules I O Interface Rear 1x Power button switch 1x VGA port Devices 1x SATA DOM device space Power Input 300W switching power supply Chassis Dimensions Chassis dimension 430mm x...

Page 18: ...m Power LED Indicates the power status of the system HDD LED Indicates the status of the hard drive RJ45 Type Console Serial Port Used to connect RJ45 type console devices USB Ports Used to connect USB 2 0 devices SFP Ports Used to connect SFP modules for connecting fiber optic network devices Copper LAN Ports Eight LAN ports used to connect network devices LAN Modules Two LAN module bays to insta...

Page 19: ...duction Rear Panel AC Power Socket Power Switch Expansion slot optional Expansion Slot Optional Used to install a PCI Express add on card VGA Used to connect an analog VGA monitor AC Power Socket Plug an AC power cord here before turning on the system Power Switch Press to power on or power off the system VGA ...

Page 20: ...rself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electric...

Page 21: ... jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin J...

Page 22: ...d connectors 7 1 1 2 4 1 B49 B12 B11 B1 B49 B12 B11 B1 1 3 1 3 1 3 1 3 1 2 1 2 1 2 1 6 3 1 9 15 16 10 8 5 4 1 1 7 1 7 1 7 1 11 10 19 12 24 1 13 5 8 1 4 1 6 1 3 1 2 A32 A31 B31 B32 B2 B1 A1 A2 2 60 1 59 4 1 1 2 15 16 2 1 2 1 3 1 3 1 3 1 U68 JP3 JP11 J4 J8 J10 LED15 U49 SATA4 SATA3 SATA2 SATA1 JP8 JP6 JP10 D5 U7 J3 J2 J1 JP4 JP5 J7 J6 J5 JP7 J11 CN1 SW21 J9 JUSB1 CON1 CON2 JP9 JTPMSEL1 JPWRBTN1 VGAC...

Page 23: ...ctors Jumpers RTC Clear Connector type 1x3 3 pin header 2 54mm pitch Connector location J5 ME Firmware Update Connector type 1x3 3 pin header 2 54mm pitch Connector location J6 1 3 1 3 Pin Function 1 2 Disable ME Force Update 2 3 ME Force Update 1 2 On default Pin Function 1 2 Normal 2 3 Clear CMOS 1 2 On default ...

Page 24: ...or type 1x3 3 pin header 2 54mm pitch Connector location J7 1 3 Pin Function 1 2 Disable BIOS_Recovery Mode 2 3 Enable BIOS_Recovery Mode 1 2 On default TPM Select Pin Header Connector type 1x3 3 pin header 2 54mm pitch Connector location JTPMSEL1 1 3 Pin Function 1 2 Enable Some Special Commands 2 3 Disable Some Special Commands 2 3 On default ...

Page 25: ...s and Connectors Console CTS Strap Pin Header Connector type 1x3 3 pin header 2 54mm pitch Connector location JP7 BMC Strap Connector type 1x2 2 pin header 2 54mm pitch Connector location JP5 1 3 Pin Function 1 2 RTS to CTS 2 3 CTS 2 3 On default Pin Function NC Enable BMC 1 2 Disable BMC NC default 1 2 ...

Page 26: ...hts Reserved 11 NSA 5160 User Manual Chapter 2 Jumpers and Connectors Console UART Controller Strap Connector type 1x2 2 pin header 2 54mm pitch Connector location JP4 Pin Function NC System UART Controller 1 2 BMC Debug UART Controller NC default 1 2 ...

Page 27: ...tion SW21 Pin Definition 1 GND 2 RST_BTN_N 1 2 RS232 Console and Dual USB 2 0 Port Connector type RJ45 port and USB 2 0 ports Type A Connector location CN1 RS232 Console Pin Definition Pin Definition 1 SP_RTS1_R 2 SP_DTR1_R 3 SP_TXD1_R 4 GND 5 SP_DCD1_R 6 SP_RXD1_R 7 SP_DSR1_R 8 SP_CTS1_CON USB Pin Definition Pin Definition 1 VCC5 2 USB 2N 3 USB 2P 4 GND 5 VCC5 6 USB 1N 7 USB 1P 8 GND 8 1 1 5 8 4 ...

Page 28: ...onnector Pin Definitions Internal Connectors Power Button Connector type 1x2 2 pin header Connector location JPWRBTN1 Pin Definition 1 GND 2 PWRBTN CPLD JTAG Pin Header Connector type 1x6 6 pin header Connector location JP9 1 2 1 6 Pin Definition Pin Definition 1 P3V_STBY 2 GND 3 JTAG_ TCK 4 JTAG_TDO 5 JTAG_TDI 6 JTAG_TMS ...

Page 29: ...0 20 pin header Connector location JUSB1 Pin Definition Pin Definition 1 P5V 2 NC 3 NC 4 GND 5 NC 6 NC 7 GND 8 NC 9 NC 10 GND 11 USB2_L_DP0 12 USB2_L_DN0 13 GND 14 USB3_L_TX_P1 15 USB3_L_TX_N1 16 GND 17 USB3_L_RX_P1 18 USB3_L_RX_N1 19 P5V 2 1 20 19 SATA DOM Power Connector Connector type 1x2 2 pin header Connector location J9 Pin Definition 1 P5V 2 GND 1 2 ...

Page 30: ...pe 1x4 4 pin Wafer Connector location FAN1 and FAN2 Pin Definition 1 GND 2 P12V 3 TACH 4 PWN 1 4 VGA Connector Connector type 2x8 16 pin header Connector location VGACONN1 Pin Definition Pin Definition 1 DACROA_B 2 DACGOA_B 3 DACBOA_B 4 NC 5 GND 6 GND 7 GND 8 GND 9 VGA_VCC 10 GND 11 NC 12 AVSYNCO_B 13 AHSYNCO_B 14 AVSYNCO_B 15 DDC_CLKO_B 16 NC 1 2 15 16 ...

Page 31: ...ctor Connector type 1x6 6 pin header Connector location J11 Pin Definition Pin Definition 1 IBMC_LCM_TXD 2 IBMC_LCM_RXD 3 GND 4 P5V 5 LCM_LED_KR_N 6 LCM_LED_KG_N 1 6 6 1 ATX Power Connector Connector type 2x4 8 pin header Connector location CON1 Pin Definition Pin Definition 1 GND 2 GND 3 GND 4 GND 5 P12V 6 P12V 7 P12V 8 P12V 1 5 8 4 ...

Page 32: ...pers and Connectors ATX Power Connector Connector type 2x12 24 pin header Connector location CON2 Pin Definition Pin Definition 1 3 3V 2 3 3V 3 GND 4 5V 5 GND 6 5V 7 GND 8 PW OK 9 5VSB 10 12V 11 12V 12 3 3V 13 3 3V 14 12V 15 GND 16 GND 17 GND 18 GND 19 GND 20 RES 5V 21 5V 22 5V 23 5V 24 GND 1 12 13 24 ...

Page 33: ...TA3 Port USB3 0 1x USB3 0 Port 1x SATA DOM Internal Connector SATA3 PCIe Gen3 x1 SMBus LPC 33MHz UART SPI AST 2300 VIDEO RGB Rear 128MB DDR 3 16MB EEPROM 10GbE EEPROM VR 12 5 PCIe Gen2 x1 PCIe Gen3 x8 CPLD XDP PCIe Gen3 x8 PCIe Gen3 x4 USB2 0 PCIe Gen2 x1 Intel I210 Intel I211 Intel I211 Intel I211 PCIe Gen2 x1 PCIe Gen2 x1 PCIe Gen3 x4 PCIe Gen2 x1 Intel I211 Intel I211 Intel I211 PCIe Gen2 x1 In...

Page 34: ...ift up the cover to remove it Chapter 3 System Setup Removing the Chassis Cover CAUTION CAUTION CAUTION Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage Lift here 1 Remove the screws on the chassis cover then put them in a safe place for later use ...

Page 35: ... 2016 NEXCOM International Co Ltd All Rights Reserved 20 NSA 5160 User Manual Chapter 3 System Setup Installing a SATA DOM 1 Locate the SATA DOM connector on the board 2 Fasten a copper post on the mounting hole ...

Page 36: ...M International Co Ltd All Rights Reserved 21 NSA 5160 User Manual Chapter 3 System Setup 3 Install the SATA DOM to the connector with the mounting hole aligned to the copper post 4 Fasten a screw on top of the copper post ...

Page 37: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 22 NSA 5160 User Manual Chapter 3 System Setup 5 Connect the power cable to the power connector on the board ...

Page 38: ...ing DIMM Memory Modules 1 Locate the DIMM sockets on the board 2 Release the locks on the DIMM sockets 3 Insert the module into the socket at an 90 degree angle Apply firm even pressure to each end of the module until it slips into the socket 4 While pushing the modules into position the lock will close automatically ...

Page 39: ...ms to avoid making unnecessary damages 1 Remove the mounting screws that secure the hard drive bracket to the chassis 2 Note the sides of the hard drive bracket The longer side is designed to fit on the chassis standoff while the shorter side is designed to fit on the motherboard s standoff Mounting screw CAUTION CAUTION CAUTION Longer side Shorter side 3 5 Bracket Longer side Shorter side 2 5 Bra...

Page 40: ...cing outwards SATA data and power connector SATA data and power connector 4 Align the mounting holes that are on the sides of the SATA drive with the mounting holes on the hard drive bracket Then use the provided mounting screws to secure the SATA drive in place 5 Repeat step 4 for securing the screws on the other side of the hard drive bracket 3 5 Bracket 3 5 Bracket 2 5 Bracket 2 5 Bracket ...

Page 41: ... User Manual Chapter 3 System Setup 6 Place the drive into the chassis with the connector side facing the board and then use the provided mounting screws to secure the hard drive bracket in place 7 Locate the SATA data connector on the board SATA data connector Connector side ...

Page 42: ...User Manual Chapter 3 System Setup 8 Plug the SATA data cable onto the connector then plug the other end to the SATA data connector on the hard drive SATA data cable SATA data connector 9 Plug the SATA power cable to the SATA power connector on the hard drive SATA power cable ...

Page 43: ...ace for later use Each cover is secured by one screw Please correctly follow the below instructions and noted items to avoid making unnecessary damages Make sure the power supply is switched off and disconnected from the power sources before replacing or adding LAN modules to prevent electric shock or system damage CAUTION CAUTION CAUTION 2 Use the handle provided and insert the handle into the tw...

Page 44: ...tor side of the module is at the rear side of the tray Important Before using Optical fiber for transferring data make sure you have connected an approved Optical Transceiver Module User needs to install appropriate and UL approved Laser Class I Transceivers rated 3 3Vdc max 1W 5 Secure the module in place with screws and slide the tray back into the bay Connector side ...

Page 45: ... is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup ...

Page 46: ...ntered the error will be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing allows you to enter Setup Legends Key Function Moves the highlight left or right to se...

Page 47: ...up screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Page 48: ...ious Values F3 Optimized Defaults F4 Save Reset ESC Exit Set the Date Use Tab to switch between Date elements BIOS Information BIOS Vendor Core Version Compliancy Project Version Build Date and Time Access Level Memory Information Total Memory System Date System Time American Megatrends 5 11 UEFI 2 4 PI 1 3 G516 0 08 x64 03 02 2016 17 53 06 Administrator 4096 MB Thu 05 26 2016 23 15 46 System Date...

Page 49: ... Stack Configuration CSM Configuration USB Configuration Trusted Computing This section is used to configure trusted computing settings Advanced Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Enabl...

Page 50: ... F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Set Parameters of Serial Port 1 COMA AST2300 Super IO Configuration Super IO Chip Serial Port 1 Configuration Serial Port 2 Configuration AST2300 Serial Port 1 Configuration This section is used to configure serial port 1 Serial Port Enables or disables the serial port Change Settings Selects an optimal setting for th...

Page 51: ...Enabled IO 2F8h IRQ 3 Auto Serial Port Console Redirection This section is used to configure the serial port that will be used for console redirection Advanced Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset...

Page 52: ...1 or more bytes Data Bits The options are 7 and 8 Bits Per Second Selects the serial port transmission speed The speed must match the other side Long or noisy lines may require a lower speed Parity A parity bit can be sent with the data bits to detect some transmission errors Even Parity bit is 0 if the number of 1 s in the data bits is even Odd Parity bit is 0 if number of 1 s in the data bits is...

Page 53: ...1 or more bytes Data Bits The options are 7 and 8 Bits Per Second Selects the serial port transmission speed The speed must match the other side Long or noisy lines may require a lower speed Parity A parity bit can be sent with the data bits to detect some transmission errors Even Parity bit is 0 if the number of 1 s in the data bits is even Odd Parity bit is 0 if number of 1 s in the data bits is...

Page 54: ...em Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Microsoft Windows Emergency Management Services EMS allows for remote management of a Windows Server OS through a serial port Out of Band Mgmt Port Terminal Type Bits per second Flow Control Data Bits Parity Stop Bits COM0 VT UTF8 115200 None 8 None 1 Out of Band Mgmt Port Configures the out o...

Page 55: ...oding Enables or disables decoding of 64bit devices in 4G address space SR IOV Support Enables or disables SR IOV support PCI Express Settings Advanced Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exi...

Page 56: ...Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Enable Disable CSM Support Compatibility Support Module Configuration CSM Support CSM16 Module Version GateA20 Active Option ROM Messages INT19 Trap R...

Page 57: ...splay mode for Option ROM The options are Force BIOS and Keep Current INT19 Trap Response Allows Option ROMs to trap Interrupt 19 when enabled Network Enables or disables the boot option for legacy network devices Video Enables or disables the boot option for legacy video devices Other PCI Devices Enables or disables the boot option for legacy PCI devices ...

Page 58: ...ble Enables Legacy USB Auto Disables support for Legacy when no USB devices are connected Disable Keeps USB devices available only for EFI applications XHCI Hand off This is a workaround for OSs that does not support XHCI hand off The XHCI ownership change should be claimed by the XHCI driver USB Configuration This section is used to configure the USB EHCI Hand Off This is a workaround for OSs tha...

Page 59: ...yright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Change Per Socket Settings Per Socket Configuration Processor Socket Socket 0 Processor ID 00050663 Processor Frequency 2 000GHz Processor Max Ratio 14H Processor Min Rati...

Page 60: ...C Exit CPU Socket 0 Configuration Processor Configuration CPU Socket 0 Configuration Processor settings for the CPU on socket 0 IntelRCSetup Save Exit Advanced Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Def...

Page 61: ...o not select Reserved Integrated Memory Controller iMC Memory Frequency Memory Topology Memory Configuration Memory Frequency Configures the maximum frequency of the memory Do not select Reserved IntelRCSetup Auto Memory Topology Save Exit Advanced Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Scree...

Page 62: ...rsion 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Selects PCIe port Bifurcation for selected slot s IOU2 IIO PCIe Port 1 IOU0 IIO PCIe Port 2 IOU1 IIO PCIe Port 3 No PCIe port active E Socket 0 PcieD00F...

Page 63: ...ave Exit Advanced Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Socket 0 PcieD0xFx Port xx PCI E Port PCI E Port Link Link Speed PCI E Port DeEmphasis PCI E Port Link Status PCI...

Page 64: ...xit Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Control to enable disable IOAT devices Allows selection of the TXT DPR size in system Enable IOAT No Snoop Disable TPH TXT DPR memory setting IIO 0 IIO IOAPIC IOAT Configuration IIO General Configuration IntelRCSetup IntelRCSetup Disable Disable Enable 3M DPR Enable...

Page 65: ...hange Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR ACPI Tables Intel VT for Directed I O VT d Intel VT for Directed I O Intel VT for Directed I O VT d IntelRCSetup Enable Intel VT for Directed I O Enables or disables Intel Virtualiza...

Page 66: ...n PCH Devices PCI Express Configuration PCH SATA Configuration USB Configuration PCH Configuration IntelRCSetup Save Exit Advanced Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit ...

Page 67: ...elp F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Enable PCIe root port function swapping feature to dynamically assign function 0 to enabled root port Control the PCI Express Root Port PCIe Root Port Function PCI Express Root Port 1 PCI Express Root Port 2 PCI Express Root Port 3 PCI Express Root Port 4 PCI Express Root Port 5 PCI Express Root Port 6 PCI Express Root Port 7 PCI ...

Page 68: ...ration IntelRCSetup Enabled AHCI Not Installed Enabled Disabled Hard Disk Drive Not Installed Enabled Disabled Hard Disk Drive Not Installed Enabled Disabled Hard Disk Drive Not Installed Enabled Disabled Hard Disk Drive SATA Controller Enables or disables the SATA controller Configure SATA as Configures the SATA as IDE or AHCI IDE This option configures the Serial ATA drives as Parallel ATA physi...

Page 69: ...e Configures the XHCI mode Trunk Clock Gating Enables or disables Trunk Clock Gating Save Exit Advanced Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Switch ByPass Auto Detect t...

Page 70: ...iguration View System Event Log BMC User Settings BMC Warm Reset PASSED 32 1 0 72 2 0 Enabled Enabled Save Exit Advanced IntelRCSetup Server Mgmt Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save ...

Page 71: ...ent Configuration Station IP address Subnet mask Station MAC address Configure IPV6 support Lan channel 1 IPV6 is not supported in BMC Unspecified DynamicAddressBmcDhcp 0 0 0 0 0 0 0 0 00 00 00 00 00 00 BMC Network Configuration Configuration Address Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters dur...

Page 72: ...efaults F4 Save Reset ESC Exit Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Press Enter to Add a User Enter BMC User Name BMC User Settings Add User Delete User Change User Settings BMC Add User Details User Name User Password Channel No User Privilege Limit 0 Reserved BMC User Settings BMC User Settings Add User ...

Page 73: ...Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Enter BMC User Name Enter BMC User Name BMC Delete User Details User Name User Password BMC Change User Settings User Name User Password Use...

Page 74: ... Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Reset ESC Exit Set Administrator Password Password Description If ONLY the Administrator s password is set then this only limits access to Setup and is only asked for when entering Setup If ONLY the User s password is set then this is a power on password and must be entered to bo...

Page 75: ... Boot Order Priorities Adjust the boot sequence of the system Boot Option 1 is the first boot device that the system will boot from next will be Boot Option 2 and so forth Save Exit Advanced IntelRCSetup Server Mgmt Security Boot Main Version 2 17 1255 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change...

Page 76: ...n press Enter A dialog box will appear Confirm by selecting Yes You can also press F4 to save and exit Setup Discard Changes and Exit To exit the Setup utility without saving the changes select this field then press Enter You may be prompted to confirm again before exiting You can also press ESC to exit without saving the changes Save Changes and Reset To save the changes and reset select this fie...

Reviews: