USER GUIDE

TB-414X

Screw Terminal Connector Kit for PXIe-414x SMUs

This document explains how to install and use the TB-414X terminal block with a PXIe-414

x

source measure unit (SMU) and includes TB-414X specifications.

The TB-414X terminal block is used to convert the 25-position D-SUB connector of the
PXIe-414

x

 SMU to screw terminal connections while maintaining low leakage performance.

Read this document before you install, configure, operate, or maintain this product. Users are
required to familiarize themselves with installation and wiring instructions in addition to
requirements of all applicable codes, laws, and standards. Visit 

ni.com/manuals

 for more

information about your product, including specifications, pinouts, and instructions for
connecting, installing, and configuring your system.

Caution

 

Observe all instructions and cautions in the user documentation. Using

the product in a manner not specified can damage the product and compromise the
built-in safety protection.

Attention

 

Suivez toutes les instructions et respectez toutes les mises en garde de la

documentation d'utilisation. L'utilisation du produit de toute autre façon que celle
spécifiée risque de l'endommager et de compromettre la protection de sécurité
intégrée.

Notice

 

This device is intended for use only with the PXIe-4140, PXIe-4141,

PXIe-4142, PXIe-4143, PXIe-4144, PXIe-4145, and PXIe-4147 SMUs, which are
referred to collectively as PXIe-414

x

 SMUs. For more information about the

PXIe-414

x

 SMUs, refer to 

ni.com/manuals

.

Contents

Icons.......................................................................................................................................... 2
Getting Started with the TB-414X............................................................................................ 2

Kit Contents and Other Equipment...................................................................................2
Installing the TB-414X..................................................................................................... 3

TB-414X Specifications............................................................................................................7

Definitions.........................................................................................................................7
Voltage, Current, and Resistance...................................................................................... 8
Isolation.............................................................................................................................9
Screw Terminal Wiring..................................................................................................... 9

Summary of Contents for TB-414X

Page 1: ...nstalling and configuring your system Caution Observe all instructions and cautions in the user documentation Using the product in a manner not specified can damage the product and compromise the buil...

Page 2: ...when you see this icon printed on the model Cautionary statements are localized into French for compliance with Canadian requirements Getting Started with the TB 414X Kit Contents and Other Equipment...

Page 3: ...ze negative effects from wiring insulation materials and contaminants The SHDB25F DB25F LL cable accessory has been designed with these considerations in mind and utilizes the TB 414X allowing for one...

Page 4: ...the stripped end of the wires into the appropriate terminals and tighten the screws of the screw terminals to a torque of 0 5 Nm 4 lb in Refer to the following pinout signal information and PXIe 414x...

Page 5: ...H 1 C H 2 Table 1 TB 414X Signals and DB25 Pin Map Screw Terminal DB25 Connector Pin LO Connector CH 0 LO 16 CH 0 LO S 3 CH 1 LO 19 CH 1 LO S 6 CH 2 LO 22 CH 2 LO S 9 CH 3 LO 25 CH 3 LO S 12 CH S GND...

Page 6: ...he strain relief upward If you are connecting only a few wires assemble the strain relief downward for greater retention Figure 3 TB 414X Strain Relief 1 2 1 Strain Relief Up 2 Strain Relief Down b In...

Page 7: ...ations These specifications apply to the TB 414X for use with the PXIe 414x The PXIe 414x is a 4 Channel SMU Refer to the module specifications at ni com manuals for more information Definitions Warra...

Page 8: ...nel at the DUT end of the cable must ensure that LO path wiring resistances are matched within 20 to prevent the LO terminal of one channel from carrying a significant portion of another channel s LO...

Page 9: ...ements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts of equipment circuits powered by regulated low vol...

Page 10: ...ronmental Guidelines Notice This model is intended for use in indoor applications only Environmental Characteristics Temperature and Humidity Temperature Operating 0 C to 55 C6 Storage 40 C to 71 C 6...

Page 11: ...NI customers For additional environmental information refer to the Commitment to the Environment web page at ni com environment This page contains the environmental regulations and directives with whi...

Page 12: ...RMA by NI does not constitute export authorization The user must comply with all applicable export laws prior to exporting or re exporting this product See ni com legal export compliance for more inf...

Page 13: ...f help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Pro...

Page 14: ...LAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how...

Reviews: